IO-Link port 3
Binary output configuration for IO-Link port 3:
|
①
|
Selection of the status signals
|
②
|
Inversion (optional)
|
③
|
Mappable objects
|
④
|
Parameter
|
Address
|
Name / setting range / [default setting]
|
Information
|
|
|
0x2651:065
|
Binary output configuration: IOL3 BO1 value
–
Read only
|
Parameter object that can be assigned to the process output data of IO-Link port 3 via the IOL3-TPDO mapping (0x24D5:001 ... 0x24D5:016).
–
Mapping entry = 0x26514101
|
|
|
0x2651:066
|
Binary output configuration: IOL3 BO1 source
|
||
|
0
|
Not connected
|
No trigger assigned (trigger is constantly FALSE).
|
|
|
0x2651:067
|
Binary output configuration: IOL3 BO1 inversion
|
||
|
0
|
Not inverted
|
||
|
1
|
Inverted
|
||
|
0x2651:069
|
Binary output configuration: IOL3 BO2 value
–
Read only
|
Parameter object that can be assigned to the process output data of IO-Link port 3 via the IOL3-TPDO mapping (0x24D5:001 ... 0x24D5:016).
–
Mapping entry = 0x26514501
|
|
|
0x2651:070
|
Binary output configuration: IOL3 BO2 source
|
||
|
0
|
Not connected
|
No trigger assigned (trigger is constantly FALSE).
|
|
|
0x2651:071
|
Binary output configuration: IOL3 BO2 inversion
|
||
|
0
|
Not inverted
|
||
|
1
|
Inverted
|
||
|
0x2651:073
|
Binary output configuration: IOL3 BO3 value
–
Read only
|
Parameter object that can be assigned to the process output data of IO-Link port 3 via the IOL3-TPDO mapping (0x24D5:001 ... 0x24D5:016).
–
Mapping entry = 0x26514901
|
|
|
0x2651:074
|
Binary output configuration: IOL3 BO3 source
|
||
|
0
|
Not connected
|
No trigger assigned (trigger is constantly FALSE).
|
|
|
0x2651:075
|
Binary output configuration: IOL3 BO3 inversion
|
||
|
0
|
Not inverted
|
||
|
1
|
Inverted
|
||
|
0x2651:077
|
Binary output configuration: IOL3 BO4 value
–
Read only
|
Parameter object that can be assigned to the process output data of IO-Link port 3 via the IOL3-TPDO mapping (0x24D5:001 ... 0x24D5:016).
–
Mapping entry = 0x26514D01
|
|
|
0x2651:078
|
Binary output configuration: IOL3 BO4 source
|
||
|
0
|
Not connected
|
No trigger assigned (trigger is constantly FALSE).
|
|
|
0x2651:079
|
Binary output configuration: IOL3 BO4 inversion
|
||
|
0
|
Not inverted
|
||
|
1
|
Inverted
|
||
|
0x2651:081
|
Binary output configuration: IOL3 BO5 value
–
Read only
|
Parameter object that can be assigned to the process output data of IO-Link port 3 via the IOL3-TPDO mapping (0x24D5:001 ... 0x24D5:016).
–
Mapping entry = 0x26515101
|
|
|
0x2651:082
|
Binary output configuration: IOL3 BO5 source
|
||
|
0
|
Not connected
|
No trigger assigned (trigger is constantly FALSE).
|
|
|
0x2651:083
|
Binary output configuration: IOL3 BO5 inversion
|
||
|
0
|
Not inverted
|
||
|
1
|
Inverted
|
||
|
0x2651:085
|
Binary output configuration: IOL3 BO6 value
–
Read only
|
Parameter object that can be assigned to the process output data of IO-Link port 3 via the IOL3-TPDO mapping (0x24D5:001 ... 0x24D5:016).
–
Mapping entry = 0x26515501
|
|
|
0x2651:086
|
Binary output configuration: IOL3 BO6 source
|
||
|
0
|
Not connected
|
No trigger assigned (trigger is constantly FALSE).
|
|
|
0x2651:087
|
Binary output configuration: IOL3 BO6 inversion
|
||
|
0
|
Not inverted
|
||
|
1
|
Inverted
|
||
|
0x2651:089
|
Binary output configuration: IOL3 BO7 value
–
Read only
|
Parameter object that can be assigned to the process output data of IO-Link port 3 via the IOL3-TPDO mapping (0x24D5:001 ... 0x24D5:016).
–
Mapping entry = 0x26515901
|
|
|
0x2651:090
|
Binary output configuration: IOL3 BO7 source
|
||
|
0
|
Not connected
|
No trigger assigned (trigger is constantly FALSE).
|
|
|
0x2651:091
|
Binary output configuration: IOL3 BO7 inversion
|
||
|
0
|
Not inverted
|
||
|
1
|
Inverted
|
||
|
0x2651:093
|
Binary output configuration: IOL3 BO8 value
–
Read only
|
Parameter object that can be assigned to the process output data of IO-Link port 3 via the IOL3-TPDO mapping (0x24D5:001 ... 0x24D5:016).
–
Mapping entry = 0x26515D01
|
|
|
0x2651:094
|
Binary output configuration: IOL3 BO8 source
|
||
|
0
|
Not connected
|
No trigger assigned (trigger is constantly FALSE).
|
|
|
0x2651:095
|
Binary output configuration: IOL3 BO8 inversion
|
||
|
0
|
Not inverted
|
||
|
1
|
Inverted
|
||