IO-Link port 4

Binary output configuration for IO-Link port 4:
①
Selection of the status signals
②
Inversion (optional)
③
Mappable objects
④
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2651:097
Binary output configuration: IOL4 BO1 value
–
Read only
 
Parameter object that can be assigned to the process output data of IO-Link port 4 via the IOL4-TPDO mapping (0x24D7:001 ... 0x24D7:016).
–
Mapping entry = 0x26516101
 
0x2651:098
Binary output configuration: IOL4 BO1 source
–
For further possible settings, see parameter 0x2651:002.
 
0
Not connected
No trigger assigned (trigger is constantly FALSE).
0x2651:099
Binary output configuration: IOL4 BO1 inversion
0
Not inverted
1
Inverted
0x2651:101
Binary output configuration: IOL4 BO2 value
–
Read only
 
Parameter object that can be assigned to the process output data of IO-Link port 4 via the IOL4-TPDO mapping (0x24D7:001 ... 0x24D7:016).
–
Mapping entry = 0x26516501
 
0x2651:102
Binary output configuration: IOL4 BO2 source
–
For further possible settings, see parameter 0x2651:002.
 
0
Not connected
No trigger assigned (trigger is constantly FALSE).
0x2651:103
Binary output configuration: IOL4 BO2 inversion
0
Not inverted
1
Inverted
0x2651:105
Binary output configuration: IOL4 BO3 value
–
Read only
 
Parameter object that can be assigned to the process output data of IO-Link port 4 via the IOL4-TPDO mapping (0x24D7:001 ... 0x24D7:016).
–
Mapping entry = 0x26516901
 
0x2651:106
Binary output configuration: IOL4 BO3 source
–
For further possible settings, see parameter 0x2651:002.
 
0
Not connected
No trigger assigned (trigger is constantly FALSE).
0x2651:107
Binary output configuration: IOL4 BO3 inversion
0
Not inverted
1
Inverted
0x2651:109
Binary output configuration: IOL4 BO4 value
–
Read only
 
Parameter object that can be assigned to the process output data of IO-Link port 4 via the IOL4-TPDO mapping (0x24D7:001 ... 0x24D7:016).
–
Mapping entry = 0x26516D01
 
0x2651:110
Binary output configuration: IOL4 BO4 source
–
For further possible settings, see parameter 0x2651:002.
 
0
Not connected
No trigger assigned (trigger is constantly FALSE).
0x2651:111
Binary output configuration: IOL4 BO4 inversion
0
Not inverted
1
Inverted
0x2651:113
Binary output configuration: IOL4 BO5 value
–
Read only
 
Parameter object that can be assigned to the process output data of IO-Link port 4 via the IOL4-TPDO mapping (0x24D7:001 ... 0x24D7:016).
–
Mapping entry = 0x26517101
 
0x2651:114
Binary output configuration: IOL4 BO5 source
–
For further possible settings, see parameter 0x2651:002.
 
0
Not connected
No trigger assigned (trigger is constantly FALSE).
0x2651:115
Binary output configuration: IOL4 BO5 inversion
0
Not inverted
1
Inverted
0x2651:117
Binary output configuration: IOL4 BO6 value
–
Read only
 
Parameter object that can be assigned to the process output data of IO-Link port 4 via the IOL4-TPDO mapping (0x24D7:001 ... 0x24D7:016).
–
Mapping entry = 0x26517501
 
0x2651:118
Binary output configuration: IOL4 BO6 source
–
For further possible settings, see parameter 0x2651:002.
 
0
Not connected
No trigger assigned (trigger is constantly FALSE).
0x2651:119
Binary output configuration: IOL4 BO6 inversion
0
Not inverted
1
Inverted
0x2651:121
Binary output configuration: IOL4 BO7 value
–
Read only
 
Parameter object that can be assigned to the process output data of IO-Link port 4 via the IOL4-TPDO mapping (0x24D7:001 ... 0x24D7:016).
–
Mapping entry = 0x26517901
 
0x2651:122
Binary output configuration: IOL4 BO7 source
–
For further possible settings, see parameter 0x2651:002.
 
0
Not connected
No trigger assigned (trigger is constantly FALSE).
0x2651:123
Binary output configuration: IOL4 BO7 inversion
0
Not inverted
1
Inverted
0x2651:125
Binary output configuration: IOL4 BO8 value
–
Read only
 
Parameter object that can be assigned to the process output data of IO-Link port 4 via the IOL4-TPDO mapping (0x24D7:001 ... 0x24D7:016).
–
Mapping entry = 0x26517D01
 
0x2651:126
Binary output configuration: IOL4 BO8 source
–
For further possible settings, see parameter 0x2651:002.
 
0
Not connected
No trigger assigned (trigger is constantly FALSE).
0x2651:127
Binary output configuration: IOL4 BO8 inversion
0
Not inverted
1
Inverted