IO-Link port 2

Binary output configuration for IO-Link port 2:
①
Selection of the status signals
②
Inversion (optional)
③
Mappable objects
④
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2651:033
Binary output configuration: IOL2 BO1 value
–
Read only
 
Parameter object that can be assigned to the process output data of IO-Link port 2 via the IOL2-TPDO mapping (0x24D3:001 ... 0x24D3:016).
–
Mapping entry = 0x26512101
 
0x2651:034
Binary output configuration: IOL2 BO1 source
–
For further possible settings, see parameter 0x2651:002.
 
0
Not connected
No trigger assigned (trigger is constantly FALSE).
0x2651:035
Binary output configuration: IOL2 BO1 inversion
0
Not inverted
1
Inverted
0x2651:037
Binary output configuration: IOL2 BO2 value
–
Read only
 
Parameter object that can be assigned to the process output data of IO-Link port 2 via the IOL2-TPDO mapping (0x24D3:001 ... 0x24D3:016).
–
Mapping entry = 0x26512501
 
0x2651:038
Binary output configuration: IOL2 BO2 source
–
For further possible settings, see parameter 0x2651:002.
 
0
Not connected
No trigger assigned (trigger is constantly FALSE).
0x2651:039
Binary output configuration: IOL2 BO2 inversion
0
Not inverted
1
Inverted
0x2651:041
Binary output configuration: IOL2 BO3 value
–
Read only
 
Parameter object that can be assigned to the process output data of IO-Link port 2 via the IOL2-TPDO mapping (0x24D3:001 ... 0x24D3:016).
–
Mapping entry = 0x26512901
 
0x2651:042
Binary output configuration: IOL2 BO3 source
–
For further possible settings, see parameter 0x2651:002.
 
0
Not connected
No trigger assigned (trigger is constantly FALSE).
0x2651:043
Binary output configuration: IOL2 BO3 inversion
0
Not inverted
1
Inverted
0x2651:045
Binary output configuration: IOL2 BO4 value
–
Read only
 
Parameter object that can be assigned to the process output data of IO-Link port 2 via the IOL2-TPDO mapping (0x24D3:001 ... 0x24D3:016).
–
Mapping entry = 0x26512D01
 
0x2651:046
Binary output configuration: IOL2 BO4 source
–
For further possible settings, see parameter 0x2651:002.
 
0
Not connected
No trigger assigned (trigger is constantly FALSE).
0x2651:047
Binary output configuration: IOL2 BO4 inversion
0
Not inverted
1
Inverted
0x2651:049
Binary output configuration: IOL2 BO5 value
–
Read only
 
Parameter object that can be assigned to the process output data of IO-Link port 2 via the IOL2-TPDO mapping (0x24D3:001 ... 0x24D3:016).
–
Mapping entry = 0x26513101
 
0x2651:050
Binary output configuration: IOL2 BO5 source
–
For further possible settings, see parameter 0x2651:002.
 
0
Not connected
No trigger assigned (trigger is constantly FALSE).
0x2651:051
Binary output configuration: IOL2 BO5 inversion
0
Not inverted
1
Inverted
0x2651:053
Binary output configuration: IOL2 BO6 value
–
Read only
 
Parameter object that can be assigned to the process output data of IO-Link port 2 via the IOL2-TPDO mapping (0x24D3:001 ... 0x24D3:016).
–
Mapping entry = 0x26513501
 
0x2651:054
Binary output configuration: IOL2 BO6 source
–
For further possible settings, see parameter 0x2651:002.
 
0
Not connected
No trigger assigned (trigger is constantly FALSE).
0x2651:055
Binary output configuration: IOL2 BO6 inversion
0
Not inverted
1
Inverted
0x2651:057
Binary output configuration: IOL2 BO7 value
–
Read only
 
Parameter object that can be assigned to the process output data of IO-Link port 2 via the IOL2-TPDO mapping (0x24D3:001 ... 0x24D3:016).
–
Mapping entry = 0x26513901
 
0x2651:058
Binary output configuration: IOL2 BO7 source
–
For further possible settings, see parameter 0x2651:002.
 
0
Not connected
No trigger assigned (trigger is constantly FALSE).
0x2651:059
Binary output configuration: IOL2 BO7 inversion
0
Not inverted
1
Inverted
0x2651:061
Binary output configuration: IOL2 BO8 value
–
Read only
 
Parameter object that can be assigned to the process output data of IO-Link port 2 via the IOL2-TPDO mapping (0x24D3:001 ... 0x24D3:016).
–
Mapping entry = 0x26513D01
 
0x2651:062
Binary output configuration: IOL2 BO8 source
–
For further possible settings, see parameter 0x2651:002.
 
0
Not connected
No trigger assigned (trigger is constantly FALSE).
0x2651:063
Binary output configuration: IOL2 BO8 inversion
0
Not inverted
1
Inverted