IO-Link port 4

Analog output configuration for IO-Link port 4:
①
Mapping of the analog values
③
Scaling
⑤
②
Display of unscaled analog values
④
mappable objects (scaled analog values)
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2653:091
Analog output configuration: IOL4 AO1 source address
0 ... [0] ... 4294967295
Mapping of the parameter whose analog value is to be output via IO-Link.
–
Format of the mapping entry: 0xiiiissll (iiii = Index, ss = Subindex, ll = length in bits)
 
–
Transmit mapping must be allowed for the mapped parameter.
 
0x2653:092
Analog output configuration: IOL4 AO1 source value
–
Read only
 
Parameter object into which the value of a parameter is written by means of mapping (subindex 91). The value of the mapped parameter is the input value for scaling.
0x2653:094
Analog output configuration: IOL4 AO1 scaled value
–
Read only
 
Parameter object with scaled value that can be assigned to the process output data of IO-Link port 4 via the IOL4 TPDO mapping (0x24D7:001 ... 0x24D7:016).
–
Mapping entry = 0x26535Exx (with xx = number of bits used)
 
0x2653:095
Analog output configuration: IOL4 AO1 data type input
0
Signed
1
Unsigned
0x2653:096
Analog output configuration: IOL4 AO1 bits input
2 ... [16] ... 32
Number of the valid bits.
0x2653:097
Analog output configuration: IOL4 AO1 scaling #A1min
-2147483648 ... [0] ... 2147483647
Scaling
–
The data range depends on the data type (signed/unsigned) and the set number of valid bits.
 
0x2653:098
Analog output configuration: IOL4 AO1 scaling #A2max
-2147483648 ... [65535] ... 2147483647
0x2653:099
Analog output configuration: IOL4 AO1 data type output
0
Signed
1
Unsigned
0x2653:100
Analog output configuration: IOL4 AO1 bits output
2 ... [16] ... 32
Number of the valid bits.
0x2653:101
Analog output configuration: IOL4 AO1 scaling #B1min
-2147483648 ... [0] ... 2147483647
Scaling
–
The data range depends on the data type (signed/unsigned) and the set number of valid bits.
 
0x2653:102
Analog output configuration: IOL4 AO1 scaling #B2max
-2147483648 ... [65535] ... 2147483647
0x2653:105
Analog output configuration: IOL4 AO1 status
–
For further possible settings, see parameter 0x2652:015.
 
0
Inactive
0x2653:106
Analog output configuration: IOL4 AO2 source address
0 ... [0] ... 4294967295
Mapping of the parameter whose analog value is to be output via IO-Link.
–
Format of the mapping entry: 0xiiiissll (iiii = Index, ss = Subindex, ll = length in bits)
 
–
Transmit mapping must be allowed for the mapped parameter.
 
0x2653:107
Analog output configuration: IOL4 AO2 source value
–
Read only
 
Parameter object into which the value of a parameter is written by means of mapping (subindex 106). The value of the mapped parameter is the input value for scaling.
0x2653:109
Analog output configuration: IOL4 AO2 scaled value
–
Read only
 
Parameter object with scaled value that can be assigned to the process output data of IO-Link port 4 via the IOL4 TPDO mapping (0x24D7:001 ... 0x24D7:016).
–
Mapping entry = 0x26536Dxx (with xx = number of bits used)
 
0x2653:110
Analog output configuration: IOL4 AO2 data type input
0
Signed
1
Unsigned
0x2653:111
Analog output configuration: IOL4 AO2 bits input
2 ... [16] ... 32
Number of the valid bits.
0x2653:112
Analog output configuration: IOL4 AO2 scaling #A1min
-2147483648 ... [0] ... 2147483647
Scaling
–
The data range depends on the data type (signed/unsigned) and the set number of valid bits.
 
0x2653:113
Analog output configuration: IOL4 AO2 scaling #A2max
-2147483648 ... [65535] ... 2147483647
0x2653:114
Analog output configuration: IOL4 AO2 data type output
0
Signed
1
Unsigned
0x2653:115
Analog output configuration: IOL4 AO2 bits output
2 ... [16] ... 32
Number of the valid bits.
0x2653:116
Analog output configuration: IOL4 AO2 scaling #B1min
-2147483648 ... [0] ... 2147483647
Scaling
–
The data range depends on the data type (signed/unsigned) and the set number of valid bits.
 
0x2653:117
Analog output configuration: IOL4 AO2 scaling #B2max
-2147483648 ... [65535] ... 2147483647
0x2653:120
Analog output configuration: IOL4 AO2 status
–
For further possible settings, see parameter 0x2652:015.
 
0
Inactive