IO-Link port 1

Analog output configuration for IO-Link port 1:
①
Mapping of the analog values
③
Scaling
⑤
②
Display of unscaled analog values
④
mappable objects (scaled analog values)
 
Parameter
Address
Name / setting range / [default setting]
Information
0x2653:001
Analog output configuration: IOL1 AO1 source address
0 ... [0] ... 4294967295
Mapping of the parameter whose analog value is to be output via IO-Link.
–
Format of the mapping entry: 0xiiiissll (iiii = Index, ss = Subindex, ll = length in bits)
 
–
Transmit mapping must be allowed for the mapped parameter.
 
0x2653:002
Analog output configuration: IOL1 AO1 source value
–
Read only
 
Parameter object into which the value of a parameter is written by means of mapping (subindex 1). The value of the mapped parameter is the input value for scaling.
0x2653:004
Analog output configuration: IOL1 AO1 scaled value
–
Read only
 
Parameter object with scaled value that can be assigned to the process output data of IO-Link port 1 via the IOL1 TPDO mapping (0x24D1:001 ... 0x24D1:016).
–
Mapping entry = 0x265304xx (with xx = number of bits used)
 
0x2653:005
Analog output configuration: IOL1 AO1 data type input
0
Signed
1
Unsigned
0x2653:006
Analog output configuration: IOL1 AO1 bits input
2 ... [16] ... 32
Number of the valid bits.
0x2653:007
Analog output configuration: IOL1 AO1 scaling #A1min
-2147483648 ... [0] ... 2147483647
Scaling
–
The data range depends on the data type (signed/unsigned) and the set number of valid bits.
 
0x2653:008
Analog output configuration: IOL1 AO1 scaling #A2max
-2147483648 ... [65535] ... 2147483647
0x2653:009
Analog output configuration: IOL1 AO1 data type output
0
Signed
1
Unsigned
0x2653:010
Analog output configuration: IOL1 AO1 bits output
2 ... [16] ... 32
Number of the valid bits.
0x2653:011
Analog output configuration: IOL1 AO1 scaling #B1min
-2147483648 ... [0] ... 2147483647
Scaling
–
The data range depends on the data type (signed/unsigned) and the set number of valid bits.
 
0x2653:012
Analog output configuration: IOL1 AO1 scaling #B2max
-2147483648 ... [65535] ... 2147483647
0x2653:015
Analog output configuration: IOL1 AO1 status
–
For further possible settings, see parameter 0x2652:015.
 
0
Inactive
0x2653:016
Analog output configuration: IOL1 AO2 source address
0 ... [0] ... 4294967295
Mapping of the parameter whose analog value is to be output via IO-Link.
–
Format of the mapping entry: 0xiiiissll (iiii = Index, ss = Subindex, ll = length in bits)
 
–
Transmit mapping must be allowed for the mapped parameter.
 
0x2653:017
Analog output configuration: IOL1 AO2 source value
–
Read only
 
Parameter object into which the value of a parameter is written by means of mapping (subindex 16). The value of the mapped parameter is the input value for scaling.
0x2653:019
Analog output configuration: IOL1 AO2 scaled value
–
Read only
 
Parameter object with scaled value that can be assigned to the process output data of IO-Link port 1 via the IOL1 TPDO mapping (0x24D1:001 ... 0x24D1:016).
–
Mapping entry = 0x265313xx (with xx = number of bits used)
 
0x2653:020
Analog output configuration: IOL1 AO2 data type input
0
Signed
1
Unsigned
0x2653:021
Analog output configuration: IOL1 AO2 bits input
2 ... [16] ... 32
Number of the valid bits.
0x2653:022
Analog output configuration: IOL1 AO2 scaling #A1min
-2147483648 ... [0] ... 2147483647
Scaling
–
The data range depends on the data type (signed/unsigned) and the set number of valid bits.
 
0x2653:023
Analog output configuration: IOL1 AO2 scaling #A2max
-2147483648 ... [65535] ... 2147483647
0x2653:024
Analog output configuration: IOL1 AO2 data type output
0
Signed
1
Unsigned
0x2653:025
Analog output configuration: IOL1 AO2 bits output
2 ... [16] ... 32
Number of the valid bits.
0x2653:026
Analog output configuration: IOL1 AO2 scaling #B1min
-2147483648 ... [0] ... 2147483647
Scaling
–
The data range depends on the data type (signed/unsigned) and the set number of valid bits.
 
0x2653:027
Analog output configuration: IOL1 AO2 scaling #B2max
-2147483648 ... [65535] ... 2147483647
0x2653:030
Analog output configuration: IOL1 AO2 status
–
For further possible settings, see parameter 0x2652:015.
 
0
Inactive