Access to extended control and status information

Via the "Properties" of the FB, extended control or status information of the drive can be accessed.

i700
  • LControlword
    Write access to 0x2830 if this index is contained in the current mapping (default).
    • For instance, DC-injection braking can be triggered via bit 6
  • LStatusword
    Read access to 0x2831 if this index is contained in the current mapping (default)
  • LStatusword2
    Read access to 0x2833 if this index is contained in the current mapping (default)
i500
  • LControlword
    Write access to 0x4008/1 if this index is contained in the current mapping (default).
    • In the default assignment parameterised in 0x400E, DC-injection braking can be triggered via bit 9. Selection 8 ("RunForward"), however, must not be interconnected in 0x400E/1..16.
    • Indexes 0x2634/1 and 0x2634/2 can be used to interconnect some bits of the control word to digital outputs of the i500.
  • LControlword2
    Write access to 0x4008/2 if this index is contained in the current mapping.
  • LControlword3
    Write access to 0x4008/3 if this index is contained in the current mapping.
  • LControlword4
    Write access to 0x4008/4 if this index is contained in the current mapping.
  • LStatusword
    Read access to 0x400A/1 if this index is contained in the current mapping (default).
  • LStatusword2
    Read access to 0x400A/2 if this index is contained in the current mapping.