Monitoring
"Switch on" monitoring time
If the axis is not enabled after the "axis on" request and after the monitoring time set in the axis parameters has elapsed, an error is reported and it is changed to the "ErrorStop" axis state.
Monitoring - runtime (subindex 101)
|
|
|||||||||||
|
Monitoring time after which the drive has to be definitely ready for operation. |
|||||||||||
|
Setting range (min. value | unit | max. value) |
Lenze setting |
||||||||||
|
0 |
s |
120 |
10.0Â s |
||||||||
|
|
FLOAT_32 |
||||||||||
Monitoring the direction of rotation
The inputs EnablePositive and EnableNegative can be used to enable or inhibit the process to a certain direction of rotation.
When a motion job is requested (e.g. MC_MoveAbsolute ), it is checked whether the resulting motion (incl. a possible reversing process) is permissible. If this is not the case, it is changed to the "ErrorStop" axis state.