Profile data switch-over
For the reference search, two profile data sets with different velocities and accelerations can be parameterised. Like this, the homing time can be reduced, and at the same time accuracy can be increased.
- With the profile data set 1 first the limit switch/reference switch (depending on the mode selected) is quickly approached.
- After reversing to the limit switch / reference switch, the encoder zero pulse/ touch probe sensor is then approached more slowly - but also more accurately - with profile data set 2, and then possibly positioning to the target position is executed.
- The exact time at which the switch-over to profile data set 2 is executed in the respective homing mode can be gathered from the process descriptions in the following chapter.
- If the velocity 2 = "0" is set (initial value), no switch-over to profile data set 2 takes place and the reference search is only carried out with the profile parameters of profile data set 1.