Operation with virtual axis
Version compatibility
Up to version v 3.26.0 of the library L_TW2P_TechModulesWindingTraversing, the operation of the TM Winder with a virtual axis is not supported. The TM switches to the error state "InvalidInverter" as soon as a virtual axis is connected. The error state cannot be acknowledged.
With the library L_TW2P_TechModulesWindingTraversing from version v 3.26.0, the operation of the TMs Winder with a virtual axis is supported. Here, the winding operation is simulated without switching to error state.
Application examples for the operation of the TM Winder with connected virtual axis.
-
Preparation of an application for commissioning
-
Simulation of an application on a controller
Functional description
Winding operation is simulated without switching to error state. The axis guidance is move in CSP. The calculation of the line feedforward is carried out here. The process controller for tension control is deactivated.
For the simulation of the winding operation, a motor with the following characteristics is simulated:
-
Rated speed: 4000 rpm
-
Nominal torque: 100 Nm
The values can be overwritten via access points!
|
Access Point Datatyp |
Description |
|
|---|---|---|
|
AP_ xVirtualRatedVelocity BOOL |
Valid only for operation with virtual axis! Enable the AP_lrVirtualRatedVelocity |
|
| TRUE | RatedVelocity := AP_lrRatedVelocity | |
| FALSE | RatedVelocity := default 4000 rpm | |
|
AP_lrVirtualRatedVelocity LREAL |
Simulate rated velocity for operation with virtual axis
|
|
|
AP_ xVirtualRatedTorque BOOL |
Valid only for operation with virtual axis! Enable the AP_lrVirtualRatedTorque |
|
| TRUE | TRUE: RatedTorque := AP_lrVirtualRatedTorque | |
| FALSE | FALSE: RatedTorque := default 100 Nm | |
|
AP_lrVirtualRatedTorque LREAL |
Simulate rated troque for operation with virtual axis
|
|
The following functions are not possible with virtual axis
Identification of the mass inertia
When activating -> TM switches to error state
-
xError = TRUE
-
eErrorID = InvalidInverter
Friction identification
When activating -> TM switches to error state
-
xError = TRUE
-
eErrorID = InvalidInverter
Pre-control of the acceleration
When activating -> TM switches warning
-
xWarning = TRUE
-
eErrorID = VirtualAxisNotSupported
Friction pilot control
When activating -> TM switches warning
-
xWarning = TRUE
-
eErrorID = VirtualAxisNotSupported