Operation with virtual axis

Version compatibility

Up to version v 3.26.0 of the library L_TW2P_TechModulesWindingTraversing, the operation of the TM Winder with a virtual axis is not supported. The TM switches to the error state "InvalidInverter" as soon as a virtual axis is connected. The error state cannot be acknowledged.

With the library L_TW2P_TechModulesWindingTraversing from version v 3.26.0, the operation of the TMs Winder with a virtual axis is supported. Here, the winding operation is simulated without switching to error state.

Application examples for the operation of the TM Winder with connected virtual axis.

  • Preparation of an application for commissioning

  • Simulation of an application on a controller

Functional description

Winding operation is simulated without switching to error state. The axis guidance is move in CSP.  The calculation of the line feedforward is carried out here. The process controller for tension control is deactivated.

For the simulation of the winding operation, a motor with the following characteristics is simulated:

  • Rated speed: 4000 rpm

  • Nominal torque: 100 Nm

The values can be overwritten via access points!

Access Point

Datatyp

Description

AP_ xVirtualRatedVelocity

BOOL

Valid only for operation with virtual axis!

Enable the AP_lrVirtualRatedVelocity

TRUE RatedVelocity := AP_lrRatedVelocity
FALSE RatedVelocity := default 4000 rpm

AP_lrVirtualRatedVelocity

LREAL

Simulate rated velocity for operation with virtual axis

  • Unit: rpm

  • Initial value: 4000

AP_ xVirtualRatedTorque

BOOL

Valid only for operation with virtual axis!

Enable the AP_lrVirtualRatedTorque

TRUE TRUE:  RatedTorque := AP_lrVirtualRatedTorque
FALSE FALSE: RatedTorque := default 100 Nm

AP_lrVirtualRatedTorque

LREAL

Simulate rated troque for operation with virtual axis

  • Unit: Nm

  • Initial value: 100

The following functions are not possible with virtual axis

Identification of the mass inertia

When activating -> TM switches to error state

  • xError = TRUE

  • eErrorID = InvalidInverter

Friction identification

When activating -> TM switches to error state

  • xError = TRUE

  • eErrorID = InvalidInverter

Pre-control of the acceleration

When activating -> TM switches warning

  • xWarning = TRUE

  • eErrorID = VirtualAxisNotSupported

Friction pilot control

When activating -> TM switches warning

  • xWarning = TRUE

  • eErrorID = VirtualAxisNotSupported