Acceleration compensation

The acceleration in the line velocity setpoint is a disturbance in the winding process.

In conjunction with the speed controlled dancer position control, an acceleration pre-control can be used to pre-control the speed controller. This is particularly useful in highly dynamic applications. The tractive force itself is solely applied via the dancer.

Calculation of the acceleration torque

with

Symbol

Description

Dimension unit

M

Acceleration torque

Nm

¹ n

(Delta) motor speed

revs/s

¹ t

(Delta ) time

s

J const

Constant moment of inertia

kgm 2

J var

Variable (diameter-dependent) moment of inertia

J max

Maximum moment of inertia

d act

Current diameter

mm

d min

Minimum diameter (sleeve diameter)

d max

Maximum diameter

B

Material width

mm

The line speed signal is differentiated for generating an acceleration.

In practice, a line speed signal that is not ideal with a constant characteristic can be expected. Depending on the resolution and stability of this signal, the signal may have to be smoothed via the PT1 filter. The filter time is defined via the rFiltTimeAccSpd parameter.

The dead band function is applied for the purpose of noise suppression in the compensation torque calculated. In this way it is avoided that small acceleration changes only resulting from the quantisation or the noise of the line speed signal lead to a compensation torque. The lrAccCmpsDeadBandTrqScaled parameter defines up to which value the dead band takes effect.

The acceleration compensation is enabled when the xAccCmp input = TRUE.

Different material widths or material densities can be taken into consideration as a percentage via the lrMInertiaAdapt input.

The lrAccCmpsGainAcc and lrAccCmpsGainDec parameters evaluate the compensation torque calculated as a function of the effective direction. In order to avoid slack material, compensation is to be stronger during acceleration processes than during deceleration processes.

Different material widths or material densities can be taken into consideration as a percentage via the lrMInertiaAdapt input.

Parameters to be set

Identifier

Data type

Description

rFiltTimeAccSpd

REAL

PT1 filter time for the winder shaft speed for acceleration compensation

  • Unit: s

  • Initial value: 0.005

lrAccCmpsDeadBandTrqScaled

LREAL

Lagging range ( Dead band ) for the current acceleration torque

  • Unit: x 100 % (1.00 = 100 %);
    reference variable : rated motor torque [Nm]

  • Initial value: 0.1 (10 %)

lrAccCmpsGainAcc

LREAL

Gain factor for the acceleration torque in positive direction

  • Unit: x 100 % (1.00 = 100 %)

  • Value range: 0 ... 2 (0 ... 200%)

  • Initial value: 1.05 (105 %)

lrAccCmpsGainDec

LREAL

Gain factor for the acceleration torque in negative direction

  • Unit: x 100 % (1.00 = 100 %)

  • Value range: 0 ... 2 (0 ... 200%)

  • Initial value: 0.95 (95 %)

lrConstMInertia

LREAL

Constant moment of inertia at the winder shaft

  • Unit: kgcm 2

  • Initial value: 1

lrMaxMInertia

LREAL

Maximally permissible moment of inertia at the winder shaft

  • Unit: kgcm 2

  • Initial value: 10

L_TW2P_scPar_WinderDancerCtrlState