Reduced controller dynamics at low system deviation
A reduced dynamic performance of the controller with minor system deviations in most cases has a beneficial influence on the control loop damping behaviour.
The system deviation results from the difference of the setpoint value and the actual value, i.e. the difference from the lrSetDancerPosScaled input and the lrActDancerPosScaled output.
The lrReducedGain parameter is used to set the value to which the gain is to be reduced within the specified tolerance range. This means that the reduced gain (lrReducedGain) is effective in the tolerance range.
Parameters to be set
|
Identifier Data type |
Description |
|
|---|---|---|
|
lrReducedGainWindow LREAL |
Area of the system deviation with a reduced gain / sensitivity. With lrReducedGainWindow , the tolerance zone of the system deviation is defined, in which lrReducedGain takes effect.
|
|
|
lrReducedGain LREAL |
Gain of system deviation within the reduced sensitivity
|
|
L_TW2P_scPar_WinderDancerCtrlState