Web break monitoring

Via the scPar.wWebBreakMode parameter, three options for web break monitoring can be selected:

  • Web break monitoring via the evaluation of the dancer position

  • Web break monitoring via the change in diameter

  • Web break monitoring via the evaluation of the dancer position and change in diameter

Web break monitoring via the evaluation of the dancer position

As an alternative to the web break monitoring on the basis of the direction of change in the diameter, a web break can be assumed with the dancer position-controlled winder if the dancer reaches the lower limit position during operation. The monitoring function is activated with xWebBreakMonit = TRUE and wWebBreakMode parameter = 1.

Responses to a web break:

  • Holding the current diameter.

  • Setting the xWebBreak output = TRUE.

Web break monitoring via the change in diameter

In the case of a web break, the diameter calculated develops in the opposite direction of the winding direction (unwinding or rewinding), since the actual circumferential speed no longer corresponds to the line speed signal.

The monitoring function is activated with the xWebBreakMonit input = TRUE, making a diameter change opposed to the winding direction only permissible within the window set in the lrWebBreakWindow parameter.

Rewinding or unwinding is automatically detected via the sign of the line velocity and the winding direction set via the xWindingDirection input.

Web break monitoring may only be activated when the calculated diameter corresponds to the real diameter.

If web break monitoring is activated ( xWebBreakMonit = TRUE), a diameter change contrary to the winding direction specified via the xUnwind output.

After loading a starting diameter which deviates considerably from the real diameter contrary to the winding direction, this may lead to an unintentional triggering of the monitoring function. If, for instance, a starting diameter of 50% is loaded for a rewinder and the real diameter only is 45%, then a change of the diameter value to the real 45% is prevented when web break monitoring is activated.

Parameters to be set

Identifier

Data type

Description

wWebBreakMode

WORD

Mode for web break monitoring

  • Initial value: 1

0

Web break monitoring via diameter calculation and dancer position

1

Web break monitoring only via the dancer position

2

Web break monitoring only via diameter calculation

lrWebBreakWindow

LREAL

Web break window

The current diameter is compared to the previous diameter across the web break window from the last calculation cycle.

  • Unit: x 100 % (1.0 = 100 %)

  • Initial value: 0.1 (10 %)

L_TW2P_scPar_WinderDancerCtrlState