Tension control via characteristic function (Base version)

For many rewinders, the tensile force must be reduced as the diameter increases to prevent the reel from being displaced, depending on the surface and type of winding material. This is referred to as the winding characteristic or tensile force characteristic.

It is common to adjust the tensile force in the winder control unit so that any adapted setpoints can be reproduced on a pneumatic actuator, for example.

The actual tensile force setpoint from the lrSetTens input is evaluated using a linear characteristic function on the basis of the diameter to ensure that the material-dependent characteristic is achieved.

The adaptation can be done according to different principles:

Linear tensile force characteristic (dwSelectTensCurve = 0 )

Linear torque characteristic (dwSelectTensCurve = 1 )

Freely definable characteristics with 65 interpolation points (dwSelectTensCurve = 2)

Parameters to be set

Identifier

Data type

Description

dwSelectTensCurve

DWORD

Selection of the characteristic for tension control

  • Initial value: 0

0

Linear tensile force profile

1

Linear torque profile

2

Tensile force profile on the basis of a specified characteristic

alrTensCurve

ARRAY[1..65] OF LREAL

Characteristic for tension control open loop consisting of 65 values.

lrTensCurveStartDiamScaled

LREAL

Initial point of the characteristic for the tension control open loop

  • Unit: x 100 %

  • 1 = 100 % = lrMaxDiam parameter

  • Initial value: 0 (0 %)

lrTensCurveCtrlScaled

LREAL

Gradient of the characteristic for the tension control open loop

  • Unit: x 100 % (1 = 100 %)

  • Initial value: 0

The value '1' causes a constant tensile force profile and thus a proportionally increasing setpoint for the diameter.

lrMaxDiam

LREAL

Maximum diameter

  • Unit: mm

  • Initial value: 180

lrMinDiam

LREAL

Minimum diameter

  • Unit: mm

  • Initial value: 50

L_TW2P_scPar_WinderDancerCtrlState