Identification of the moments of inertia

A suitable moment of inertia is required if the acceleration compensation or the adaption of the speed controller gain is to be used.

For this purpose, the constant scPar.lrConstMInertia and the maximum moment of inertia scPar.MaxMInertia must be appropriately parameterised. During operation, the current moment of inertia is calculated as a function of the current diameter is automatically calculated and output at lrSetMInertiaOut .

The constant and maximum moment of inertia can be determined via manual calculation or by means of identification.

The maximum moment of inertia corresponds to the reel with the maximum moment of inertia, for which the winder is designed. In order to adapt the reel actually used, which can differ with regard to the material density, the maximum diameter and / or the material width, evaluation factors are provided for the acceleration compensation and speed controller gain in each case.

Identification of the constant moment of inertia

The winder shaft is empty (no material).

The lrIdentMInertiaMaxSpdScaled parameter serves to define the maximum motor speed in [x 100 %] regarding the maximally reachable winder speed lrWndSpdRef . Typically, speeds between 50 ... 60 % are sufficient.

The lrIdentMInertiaMaxTrqScaled parameter serves to define the acceleration torque. This value always has to be higher than the maximally occurring friction - recommendation: 25 %.

The mass moment of inertia is detected with a rising edge (FALSE ä TRUE) at the xExecuteIdentMInertia input. The lrIdentMInertia output displays the detected moment of inertia.

No

xExecuteIdentMInertia

xIdentBusy

xIdentDone

eTMState

INFO

A

FALSE ä TRUE

FALSE ä TRUE

FALSE

STANDBY IDENTMINERTIA

The axis is controlled in the CST torque mode. With the positive torque, which is defined by the parameter setting for the identification process, the axis is accelerated up to the identified speed defined.

B

TRUE

TRUE

FALSE

IDENTMINERTIA

The speed that is determined via the parameter setting for the identification process has been reached. The torque is commissioned in negative direction. The axis is now decelerated.

C

TRUE

TRUE æ FALSE

FALSE ä TRUE

IDENTMINERTIA

STANDBY

The axis reaches standstill and the torque is switched off. The histories recorded are evaluated and the mass inertia is determined.

D

TRUE æ FALSE

FALSE

TRUE æ FALSE

STANDBY

If the assignment for identification is reset, the "DONE" status is also reset.

The control stability of the drive and the actual value resolution of speed and torque are directly included in the calculation result of the identification process. Filtering of the current values often improves the result of the identification process:

  • Filter time for the current torque: rFiltTimeIdentMInertiaTrq

  • Filter time for the current winder speed: rFiltTimeIdentMInertiaSp

Identification of the maximum moment of inertia

The winder is loaded with the maximum possible reel (maximum diameter and maximum width).

The maximum motor speed lrIdentMInertiaMaxSpdScaled has to be parameterised so that the maximally permissible circumferential velocity of the winder will not be exceeded (e.g. lrIdentMInertiaMaxSpdScaled = 10 % at d max /d min = 10) - recommended: 25 %.

The mass moment of inertia is detected with a rising edge (FALSE ä TRUE) at the xExecuteIdentMInertia input.

Termination of the identification

The identification is completed as soon as the motor has reached standstill again, no errors have been reported and xDone has been set to TRUE.

The detected inertia of the winder shaft (J Winder ) is displayed at the lrIdentMInertia output and has to be checked for plausibility.

The identification of both types of inertia should be executed several times. In doing so, the filter time for the rFiltTimeIdentMInertiaSpd speed can be altered.

A significant non-linear friction in the system adversely affects the calculation of the moment of inertia in the technology module.

Parameters to be set

Identifier

Data type

Description

rFiltTimeIdentMInertiaSpd

REAL

PT1 filter time for the speed at the winder shaft during the identification of the moment of inertia

  • Unit: s

  • Initial value: 0.01

rFiltTimeIdentMInertiaTrq

REAL

PT1 filter time for the torque at the winder shaft during the identification of the moment of inertia

  • Unit: s

  • Initial value: 0.005

lrIdentMInertiaMaxSpdScaled

LREAL

Maximum speed of the winder shaft during the identification of the moment of inertia

  • Unit: x 100 % (1.0 = 100 % = lrWndSpdRef )

  • Value range: 0 ... 1 (0 ... 100 %)

  • Initial value: 0.2 (20 %)

lrIdentMInertiaMaxTrqScaled

LREAL

Maximum torque of the winder shaft during the identification of the moment of inertia

  • Unit: x 100 % (1.0 = 100 %)
    reference variable: rated motor torque

  • Value range: 0 ... 1 (0 ... 100 %)

  • Initial value: 0.2 (20 %)

L_TW2P_scPar_WinderDancerCtrlState

Calculation of the maximum moment of inertia

If no reel is available, the maximum moment of inertia can be calculated as follows:

Calculation of the maximum moment of inertia

The density of the winding material is known:

J MaxWinder = i² �- J Motor + ( p / 32 �- 10 8 ) �- B �- r (d max 4 - d min 4 )

The mass of the winding material is known:

J MaxWinder = i² �- J Motor + (m �- d max 4 / 800)

Symbol

Description

Dimension unit

J MaxWinder

Maximum moment of inertia of the winder shaft

kgcm 2

J Motor

Moment of inertia of the motor shaft

kgcm 2

i

Gearbox factor

B

Material width

mm

r

Material density

kg/dm 3

d max

Maximum diameter

mm

d min

Minimum diameter (sleeve diameter)

mm

m

Mass

kg

The constant moment of inertia is basically determined by the motor. Its moment of inertia is specified in the catalogue.

The values calculated or identified have to be transferred to the respective parameter:

  • scPar.lrConstMInertia

  • scPar.lrMaxMInertia

In order to store the values safe against mains failure in the device, the parameter set must be saved!