Identification of the moments of inertia
A suitable moment of inertia is required if the acceleration compensation or the adaption of the speed controller gain is to be used.
For this purpose, the constant scPar.lrConstMInertia and the maximum moment of inertia scPar.MaxMInertia must be appropriately parameterised. During operation, the current moment of inertia is calculated as a function of the current diameter is automatically calculated and output at lrSetMInertiaOut .
The constant and maximum moment of inertia can be determined via manual calculation or by means of identification.
The maximum moment of inertia corresponds to the reel with the maximum moment of inertia, for which the winder is designed. In order to adapt the reel actually used, which can differ with regard to the material density, the maximum diameter and / or the material width, evaluation factors are provided for the acceleration compensation and speed controller gain in each case.
Identification of the constant moment of inertia
The winder shaft is empty (no material).
The lrIdentMInertiaMaxSpdScaled parameter serves to define the maximum motor speed in [x 100 %] regarding the maximally reachable winder speed lrWndSpdRef . Typically, speeds between 50 ... 60 % are sufficient.
The lrIdentMInertiaMaxTrqScaled parameter serves to define the acceleration torque. This value always has to be higher than the maximally occurring friction - recommendation: 25 %.
The mass moment of inertia is detected with a rising edge (FALSE ä TRUE) at the xExecuteIdentMInertia input. The lrIdentMInertia output displays the detected moment of inertia.
|
No |
xExecuteIdentMInertia |
xIdentBusy |
xIdentDone |
eTMState |
INFO |
|---|---|---|---|---|---|
|
A |
FALSE ä TRUE |
FALSE ä TRUE |
FALSE |
STANDBY IDENTMINERTIA |
The axis is controlled in the CST torque mode. With the positive torque, which is defined by the parameter setting for the identification process, the axis is accelerated up to the identified speed defined. |
|
B |
TRUE |
TRUE |
FALSE |
IDENTMINERTIA |
The speed that is determined via the parameter setting for the identification process has been reached. The torque is commissioned in negative direction. The axis is now decelerated. |
|
C |
TRUE
|
TRUE æ FALSE |
FALSE ä TRUE |
IDENTMINERTIA STANDBY |
The axis reaches standstill and the torque is switched off. The histories recorded are evaluated and the mass inertia is determined. |
|
D |
TRUE æ FALSE |
FALSE |
TRUE æ FALSE |
STANDBY |
If the assignment for identification is reset, the "DONE" status is also reset. |
The control stability of the drive and the actual value resolution of speed and torque are directly included in the calculation result of the identification process. Filtering of the current values often improves the result of the identification process:
-
Filter time for the current torque: rFiltTimeIdentMInertiaTrq
-
Filter time for the current winder speed: rFiltTimeIdentMInertiaSp
Identification of the maximum moment of inertia
The winder is loaded with the maximum possible reel (maximum diameter and maximum width).
The maximum motor speed lrIdentMInertiaMaxSpdScaled has to be parameterised so that the maximally permissible circumferential velocity of the winder will not be exceeded (e.g. lrIdentMInertiaMaxSpdScaled = 10 % at d max /d min = 10) - recommended: 25 %.
The mass moment of inertia is detected with a rising edge (FALSE ä TRUE) at the xExecuteIdentMInertia input.
Termination of the identification
The identification is completed as soon as the motor has reached standstill again, no errors have been reported and xDone has been set to TRUE.
The detected inertia of the winder shaft (J Winder ) is displayed at the lrIdentMInertia output and has to be checked for plausibility.
The identification of both types of inertia should be executed several times. In doing so, the filter time for the rFiltTimeIdentMInertiaSpd speed can be altered.
A significant non-linear friction in the system adversely affects the calculation of the moment of inertia in the technology module.
Parameters to be set
|
Identifier Data type |
Description |
|
|---|---|---|
|
rFiltTimeIdentMInertiaSpd REAL |
PT1 filter time for the speed at the winder shaft during the identification of the moment of inertia
|
|
|
rFiltTimeIdentMInertiaTrq REAL |
PT1 filter time for the torque at the winder shaft during the identification of the moment of inertia
|
|
|
lrIdentMInertiaMaxSpdScaled LREAL |
Maximum speed of the winder shaft during the identification of the moment of inertia
|
|
|
lrIdentMInertiaMaxTrqScaled LREAL |
Maximum torque of the winder shaft during the identification of the moment of inertia
|
|
L_TW2P_scPar_WinderDancerCtrlState
Calculation of the maximum moment of inertia
If no reel is available, the maximum moment of inertia can be calculated as follows:
|
Calculation of the maximum moment of inertia |
||
|---|---|---|
|
The density of the winding material is known:
J
MaxWinder
= i²
The mass of the winding material is known:
J
MaxWinder
= i²
|
||
|
Symbol |
Description |
Dimension unit |
|
J MaxWinder |
Maximum moment of inertia of the winder shaft |
kgcm 2 |
|
J Motor |
Moment of inertia of the motor shaft |
kgcm 2 |
|
i |
Gearbox factor |
|
|
B |
Material width |
mm |
|
r |
Material density |
kg/dm 3 |
|
d max |
Maximum diameter |
mm |
|
d min |
Minimum diameter (sleeve diameter) |
mm |
|
m |
Mass |
kg |
The constant moment of inertia is basically determined by the motor. Its moment of inertia is specified in the catalogue.
The values calculated or identified have to be transferred to the respective parameter:
-
scPar.lrConstMInertia
-
scPar.lrMaxMInertia
In order to store the values safe against mains failure in the device, the parameter set must be saved!