IO-Link port 2
Analog input configuration for IO-Link port 2:
|
①
|
③
|
Scaling
|
⑤
|
Optional mapping of the scaled analog values to parameters of the inverter
|
|
|
②
|
Display of unscaled analog values
|
④
|
Display of scaled analog values
|
|
The analog inputs can not only be used as frequency setpoint source, but are also available for selection in other parameters.
Parameter
|
Address
|
Name / setting range / [default setting]
|
Information
|
|
|
0x2652:032
|
Analog input configuration: IOL2 AI1 source value
–
Read only
|
Parameter object that can be assigned to the process input data of IO-Link port 2 via the IOL2-RPDO mapping (0x24D2:001 ... 0x24D2:016).
–
Mapping entry = 0x265220xx (with xx = number of bits used)
|
|
|
0x2652:033
|
Analog input configuration: IOL2 AI1 target address
0 ... [0] ... 4294967295
|
||
|
0x2652:034
|
Analog input configuration: IOL2 AI1 scaled value
–
Read only
|
Display of the scaled value.
|
|
|
0x2652:035
|
Analog input configuration: IOL2 AI1 data type input
|
||
|
0
|
Signed
|
||
|
1
|
Unsigned
|
||
|
2
|
Float32
|
||
|
0x2652:036
|
Analog input configuration: IOL2 AI2 bits input
2 ... [16] ... 32
|
Number of the valid bits.
|
|
|
0x2652:037
|
Analog input configuration: IOL2 AI1 scaling #A1min
-2147483648 ... [0] ... 2147483647
|
Scaling
–
The data range depends on the data type (signed/unsigned) and the set number of valid bits.
|
|
|
0x2652:038
|
Analog input configuration: IOL2 AI1 scaling #A2max
-2147483648 ... [65535] ... 2147483647
|
||
|
0x2652:039
|
Analog input configuration: IOL2 AI1 data type output
|
||
|
0
|
Signed
|
||
|
1
|
Unsigned
|
||
|
0x2652:040
|
Analog input configuration: IOL2 AI1 bits output
2 ... [16] ... 32
|
Number of the valid bits.
|
|
|
0x2652:041
|
Analog input configuration: IOL2 AI1 scaling #B1min
-2147483648 ... [0] ... 2147483647
|
Scaling
–
The data range depends on the data type (signed/unsigned) and the set number of valid bits.
|
|
|
0x2652:042
|
Analog input configuration: IOL2 AI1 scaling #B2max
-2147483648 ... [65535] ... 2147483647
|
||
|
0x2652:045
|
Analog input configuration: IOL2 AI1 status
|
||
|
0
|
Inactive
|
||
|
0x2652:047
|
Analog input configuration: IOL2 AI2 source value
–
Read only
|
Parameter object that can be assigned to the process input data of IO-Link port 2 via the IOL2-RPDO mapping (0x24D2:001 ... 0x24D2:016).
–
Mapping entry = 0x26522Fxx (with xx = number of bits used)
|
|
|
0x2652:048
|
Analog input configuration: IOL2 AI2 target address
0 ... [0] ... 4294967295
|
||
|
0x2652:049
|
Analog input configuration: IOL2 AI2 scaled value
–
Read only
|
Display of the scaled value.
|
|
|
0x2652:050
|
Analog input configuration: IOL2 AI2 data type input
|
||
|
0
|
Signed
|
||
|
1
|
Unsigned
|
||
|
2
|
Float32
|
||
|
0x2652:051
|
Analog input configuration: IOL2 AI2 bits input
2 ... [16] ... 32
|
Number of the valid bits.
|
|
|
0x2652:052
|
Analog input configuration: IOL2 AI2 scaling #A1min
-2147483648 ... [0] ... 2147483647
|
Scaling
–
The data range depends on the data type (signed/unsigned) and the set number of valid bits.
|
|
|
0x2652:053
|
Analog input configuration: IOL2 AI2 scaling #A2max
-2147483648 ... [65535] ... 2147483647
|
||
|
0x2652:054
|
Analog input configuration: IOL2 AI2 data type output
|
||
|
0
|
Signed
|
||
|
1
|
Unsigned
|
||
|
0x2652:055
|
Analog input configuration: IOL2 AI2 bits output
2 ... [16] ... 32
|
Number of the valid bits.
|
|
|
0x2652:056
|
Analog input configuration: IOL2 AI2 scaling #B1min
-2147483648 ... [0] ... 2147483647
|
Scaling
–
The data range depends on the data type (signed/unsigned) and the set number of valid bits.
|
|
|
0x2652:057
|
Analog input configuration: IOL2 AI2 scaling #B2max
-2147483648 ... [65535] ... 2147483647
|
||
|
0x2652:060
|
Analog input configuration: IOL2 AI2 status
|
||
|
0
|
Inactive
|
||