Event ID overview

The following table contains the most important event IDs of the device in ascending order.
–
Clicking the event ID shows you a detailed description of the event.
 
–
If the device displays an "internal event" that is not listed here, restart the device. If the event persists, make a note of the event ID and contact the manufacturer.
 
 
Event ID
Event
Severity
Configurable in
CiA: Continuous over current (internal)
Fault
-
Short circuit or earth leakage at the motor end
Fault
-
Short circuit at the motor end
Fault
-
CiA: i²xt overload (thermal state)
Fault > inverter disabled
Fault - Device utilization (ixt) too high
Fault > inverter disabled
Warning - Device utilization (ixt) too high
Warning
-
Clamp responded too often
Fault
-
Sensorless control: stall detection active
Trouble
-
Mains phase fault
Warning
-
Fault - DC bus overvoltage
Fault
-
DC bus overvoltage warning
Warning
-
Fault - DC bus undervoltage
Trouble
-
DC bus undervoltage warning
Warning
-
DC-bus voltage too low for power up
Warning
-
Fault - Power unit overtemperature
Fault
-
Fault - Heat sink temperature sensor
Fault
-
Heat sink fan warning
Warning
-
PU overtemperature warning
Warning
-
Motor overtemperature
Fault > inverter disabled
Internal error - AIS
Warning
-
Internal error - AIE
Warning
-
Internal error - Button S82
Warning
-
SD-Inx/CLx - Error
Warning
-
Internal switch-off path - Error
Warning
-
Internal switch-off path - Test pulse error
Warning
-
External supply voltage critical
Warning
-
Reference voltage error
Warning
-
6 V voltage error
Fault
-
3.3 V voltage error
Fault
-
Overload 24 V supply
Fault > inverter disabled
Logic PLC exception error
Fault > inverter disabled
Logic PLC endless loop
Fault
-
Internal error - STO activated
Warning
-
Communication error - Basic device
Fault
-
Synchronization error - Basic device
Information
-
Warning - Internal fan
Warning
-
Internal error
Fault
-
Internal error
Fault
-
Internal error
Fault
-
Internal error
Fault
-
Trigger/functions connected incorrectly
Trouble
-
User-defined fault 1
Fault > inverter disabled
User-defined fault 2
Fault > inverter disabled
Warning invert rotation
Warning
-
Maximuml allowed troubles exceeded
Fault
-
Network: user fault 1
Fault
-
Network: user fault 2
Fault
-
NetWordIN1 configuration incorrect
Trouble
-
F_CRC_Length error
Information
-
Wrong F-parameter version
Information
-
Safety parameter set deleted
Information
-
New safety parameter set loaded
Information
-
Different safety parameter sets
Warning
-
Extended Safety - No safety parameter set
Warning
-
Extended Safety - Safety parameter set defect
Warning
-
Safety parameter set - Format error
Warning
-
Safety parameter set - Plausibility error
Warning
-
Safety parameter set - Communication error
Warning
-
Different safety addresses detected
Warning
-
Memory module release information - access error
Information
-
Internal limitation active
Warning
-
CU: load error ID tag
Fault
-
PU: load error ID tag
Fault
-
Power unit unknown
Fault
-
Assertion level monitoring (Low/High)
Fault
-
Analog input 1 fault
Information
Analog input 2 fault
Information
HTL input fault
No response
HTL input fault IN2
No response
Process temperature invalid
Warning
-
Process temperature lower threshold
No response
Process temperature upper threshold
No response
Analog input 1 fault
Information
Analog input 2 fault
Information
Analog output 1 fault
Warning
-
Fault - Pole position identification
Fault
-
Motor overcurrent
Fault > inverter disabled
Encoder open circuit
Warning
Feedback system: speed limit
Information
-
Invalid user data
Fault
-
Safety - Network/safety bus configuration inconsistent
Warning
-
Memory module: invalid OEM data
Warning
-
OEM data are missing
Fault
-
EPM firmware version incompatible
Fault
-
Invalid parameter changeover configuration
Warning
-
Network - Time-out explicit message
Warning
Network - Overall communication time-out
Warning
Modbus TCP master time-out
Fault > inverter disabled
Modbus TCP Keep Alive time-out
Fault > inverter disabled
PROFIsafe passivated
Information
-
PROFIsafe - CRC1 error
Information
-
Network - Watchdog time-out
Trouble
Network - Disruption of cyclic data exchange
Fault
-
Network - Initialization error
Trouble
Network - Invalid cyclic process data
Trouble
FSoE - Unexpected command
Information
-
FSoE - Unknown command
Information
-
FSoE - Invalid connection ID
Information
-
FSoE - CRC error
Information
-
FSoE - Watchdog expired
Information
-
FSoE - Invalid communication parameter data
Information
-
FSoE - Invalid application parameter length
Information
-
FSoE - Invalid application parameter data
Information
-
FSoE - Passivated
Information
-
Modbus: network time-out
Fault > inverter disabled
Modbus: incorrect request by master
Warning
-
FSoE - Invalid slave address
Information
-
FSoE - Invalid communication parameter length
Information
-
CIP Safety - Invalid Requested Packet Interval (RPI) of safety inputs
Information
-
CIP Safety - Invalid multicast input connection parameters
Information
-
CIP Safety - Invalid max. number of multicast input connections
Information
-
CIP Safety - Different originator ID of the output connection (OCPUNID)
Information
-
CIP Safety - Different safety configuration signature (SCID)
Information
-
CIP Safety - Invalid Requested Packet Interval (RPI) of outputs
Information
-
CIP Safety - Error in connection path (EPATH)
Information
-
CIP Safety - Connection management error
Information
-
CIP Safety - Device identification error
Information
-
CIP Safety - Time Coordination Message error
Information
-
CIP Safety - Output error
Information
-
CIP Safety - Time Correction Message error
Information
-
CIP Safety - Timestamp Message error
Information
-
CIP Safety - Internal communication error between safety option and basic device
Information
-
The safety protocol is not supported
Fault
-
IO-Link port 1 error
No response
IO-Link port 2 error
No response
IO-Link port 3 error
No response
IO-Link port 4 error
No response
IO-Link port 1 warning
No response
IO-Link port 2 warning
No response
IO-Link port 3 warning
No response
IO-Link port 4 warning
No response
Network - PDO mapping error
Trouble
Invalid Mapping: duplicate Rx-Entries present
Warning
-
Torque limit reached
No response
Function not allowed in selected operating mode
Warning
-
Overrun positive software limit
Warning
Overrun negative software limit
Warning
Overrun positive hardware limit switch
Warning
Overrun negative hardware limit switch
Warning
Following error - Warning level exceeded
Warning
-
Following error - Error level exceeded
Warning
Invalid profile parameters
Warning
-
Invalid positioning mode
Warning
-
Invalid acceleration
Warning
-
Invalid deceleration
Warning
-
Invalid velocity
Warning
-
Axis not homed
Fault
-
Maximum value exceeded
Warning
Target position outside software limits
Warning
-
Parameterization of positioning is implausible
Warning
-
Discrepancy check or function check error - SD-In1
Warning
-
Discrepancy check or function check error - SD-In2
Warning
-
Disabled SD-In1 = HIGH
Warning
-
Disabled SD-In2 = HIGH
Warning
-
SD-Out1 - Channel A remains stuck at HIGH
Warning
-
SD-Out1 - Channel A remains stuck at LOW
Warning
-
SD-Out1 - Channel B remains stuck at HIGH
Warning
-
SD-Out1 - Channel B remains stuck at LOW
Warning
-
SD-In1 - Channel A remains stuck at HIGH
Warning
-
SD-In1 - Channel B remains stuck at HIGH
Warning
-
SD-In2 - Channel A remains stuck at HIGH
Warning
-
SD-In2 - Channel B remains stuck at HIGH
Warning
-
CLA/CLB - Short circuit
Warning
-
Fault - Motor holding brake
Fault
-
Safe torque off (STO) activated
No response
Motor overspeed
Fault > inverter disabled
Motor phase missing
No response
Motor phase failure phase U
No response
Motor phase failure phase V
No response
Motor phase failure phase W
No response
Motor parameter identification fault
Fault
-
Automatic start disabled
Fault
-
Load loss detected
No response
Motor overload
No response
Maximum motor frequency reached
Warning
-
Manual mode disabled
Warning
-
Manual mode activated
Warning
-
Manual mode time-out
Fault
-
Safety option - Internal error
Fault
-
SW update detected
Warning
-
Internal error
Fault
-
Safety firmware update failed
Fault
-
MUT - Muting function active
Information
-
MUT - Muting function completed
Information
-
MUT - Muting function aborted
Information
-