Parameter attribute list

The parameter attribute list in particular contains some information required for reading and writing parameters via network.
 
Note the special features for writing the safe parameters of the Extended Safety:
»EASY Starter« or »PLC-Designer«: Writing the safe parameters is only possible via the "+Safe parameter list+" tab. The safe parameters can only be read via the "Parameter list" tab.
Higher-level controller: Writing of the safe parameters is possible by the parameter set transfer.
 
 
The following conventions are used in this documentation for specifying the parameter address:
• The index is specified as a hexadecimal value.
• The subindex is specified as a decimal value.
 
 
–
The parameter attribute list contains all parameters of the inverter.
 
–
The parameter attribute list is sorted by addresses (index:subindex) in ascending order.
 
How to read the parameter attribute list:
Column
Meaning
Address
Address of the parameter in the object directory. Format: Index:Subindex
Name
Parameter name
Default setting
Default setting of the parameter
Data type
Data type of the parameter:
I8
INTEGER_8
1 byte, with sign
I16
INTEGER_16
2 bytes with sign
I32
INTEGER_32
4 bytes with sign
I64
INTEGER_64
8 bytes with sign
U8
UNSIGNED_8
1 byte without sign
U16
UNSIGNED_16
2 bytes without sign
U32
UNSIGNED_32
4 bytes without sign
U64
UNSIGNED_64
8 bytes without sign
STRING[xx]
VISIBLE_STRING
ASCII string (with character length xx)
OCTET[xx]
OCTET_STRING
OCTET string (with xx bytes)
IDX
4 bytes without sign. Is used specially for addressing parameters.
Factor
Factor for data transmission via network,
depending on the number of decimal positions:
1
no decimal positions
10
1 decimal position
100
2 decimal positions
1000
3 decimal positions
10000
4 decimal positions
A
Attributes (combinations of several attributes also possible):
C
Setting can only be changed if the inverter is disabled.
E
Value is displayed as IP address.
H
Value is displayed in hexadecimal form.
T
Value is displayed as time.
M
Mapping:
●
Mapping permitted.
Mapping not permissible.
 
Parameter attribute list (short overview of all parameter indexes)
Address
Name
Default setting
Data type
Factor
A
M
Device type
- (Read only)
U32
1
-
0x1001
Error register
- (Read only)
U8
1
-
●
Manufacturer device name
- (Read only)
STRING[50]
-
Manufacturer hardware version
- (Read only)
STRING[50]
-
Manufacturer software version
- (Read only)
STRING[50]
-
Identity object: Vendor ID
- (Read only)
U32
1
-
Identity object: Product Code
- (Read only)
U32
-
Identity object: Revision number
- (Read only)
U32
1
-
Identity object: Serial number
- (Read only)
U32
1
-
Error settings: Local error reaction
Device specific state [2]
U32
-
Error settings: Sync error counter limit
20
U16
1
-
Device data: Product code
- (Read only)
STRING[50]
-
Device data: Serial number
- (Read only)
STRING[50]
-
Device data: Production date
- (Read only)
STRING[50]
-
Device data: CU firmware version
- (Read only)
STRING[50]
-
Device data: CU bootloader version
- (Read only)
STRING[50]
-
Device data: Object directory version
- (Read only)
U32
1
-
Device data: Safety module version
- (Read only)
STRING[50]
-
Device name
"Device"
STRING[128]
-
Device module: CU serial number
- (Read only)
STRING[50]
-
Device module: PU serial number
- (Read only)
STRING[50]
-
Device event monitor: EreignisortEvent location
- (Read only)
U8
-
Device event monitor: Severity
- (Read only)
U8
-
Device event monitor: Event status
- (Read only)
U8
-
Device event monitor: Number of current event
- (Read only)
U32
H
Device event monitor: Time stamp of current event
x ns (Read only)
U64
1
T
EoE information: Virtual MAC address
- (Read only)
STRING[32]
-
EoE information: IP address
- (Read only)
STRING[32]
-
EoE information: Subnet mask
- (Read only)
STRING[32]
-
EoE information: Standard gateway
- (Read only)
STRING[32]
-
EoE information: DNS server
- (Read only)
STRING[32]
-
EoE information: DNS name
- (Read only)
STRING[50]
-
EoE information: Received packages
 
U32
1
-
EoE information: Transmitted packages
 
U32
1
-
Optical tracking: Start detection
Stop [0]
U8
-
Optical tracking: Blinking duration
5 s
U16
1
-
Device commands: Load default settings
Off / ready [0]
U8
C
Device commands: Delete logbook
Off / ready [0]
U8
-
Device commands: Restart Device
Off / ready [0]
U8
-
Device commands: Export Logbook
Off / ready [0]
U8
-
Device commands: Delete Logfiles
Off / ready [0]
U8
-
Device commands: Restart extended safety
Off / ready [0]
U8
-
CRC parameter set
- (Read only)
U32
1
-
PIN1 access protection
0
I16
1
-
PIN2 access protection
0
I16
1
-
PIN1/PIN2 log-in
0
I16
1
-
Access protection status
- (Read only)
U16
H
Brand protection: PIN set
0
I32
1
-
Brand protection: PIN input
0
I32
1
-
Brand protection: Encryption
0
U8
1
-
Delete home position
Ready [0]
U8
-
0x2110:015
Activate muting
Ready [0]
U8
-
0x2110:016
Reset error
Off / ready [0]
U8
-
0x2110:017
Acknowledge restart
Off / ready [0]
U8
-
0x2110:018
Acknowledge motor encoder
Off / ready [0]
U8
-
Parameter set: Version
i750 ES V1.3 [10301]
U16
-
Parameter set: Project CRC
0
U32
1
-
Parameter set: Status
- (Read only)
U8
-
Parameter set: Current CRC
- (Read only)
U32
1
-
Parameter set: Last valid CRC
- (Read only)
U32
1
-
Parameter set: Parameter setting time stamp
x s (Read only)
U32
1
-
Parameter set: Error information 1
- (Read only)
U32
1
-
Parameter set: Error information 2
- (Read only)
U32
1
-
Parameter set: Error information 3
- (Read only)
U32
1
-
Parameter set: Current CRC without safety address
- (Read only)
U32
1
-
S-Bus configuration
FSoE/onboard EtherCAT [11]
U8
-
FSoE project CRC
 
U32
1
-
Safety software: Firmware version
- (Read only)
STRING[50]
-
Safety software: Bootloader version
- (Read only)
STRING[50]
-
Safety hardware: Hardware version
- (Read only)
STRING[50]
-
Safety hardware: Serial number
- (Read only)
STRING[50]
-
Safety hardware: Production date
- (Read only)
STRING[50]
-
Safety event history: Current severity
- (Read only)
U8
-
Safety event history: Internal event 1
- (Read only)
U16
H
Safety event history: Internal event 2
- (Read only)
U16
H
Safety event history: Internal event 3
- (Read only)
U16
H
Safety event history: Internal event 4
- (Read only)
U16
H
Safety event history: Internal event 5
- (Read only)
U16
H
Safety event history: Internal event 6
- (Read only)
U16
H
Safety event history: Internal event 7
- (Read only)
U16
H
Safety event history: Internal event 8
- (Read only)
U16
H
Safety event history: Internal event 9
- (Read only)
U16
H
Safety event history: Internal event 10
- (Read only)
U16
H
Safety event history: Internal event 11
- (Read only)
U16
H
Safety event history: Internal event 12
- (Read only)
U16
H
Safety event history: Internal event 13
- (Read only)
U16
H
Safety event history: Internal event 14
- (Read only)
U16
H
Safety event history: Internal event 15
- (Read only)
U16
H
Safety event history: Internal event 16
- (Read only)
U16
H
Safety hardware: Power-on time
x s (Read only)
U32
1
-
Safety status
- (Read only)
U16
1
-
MUT: Mute S-Bus
No muting [0]
U8
-
MUT: Password
0
U32
1
-
MUT: Remaining time
x s (Read only)
U32
1
-
0x2371:009
onboard EtherCAT: Interface mode
Slave [0]
U8
C
onboard EtherCAT - Information: Active interface mode
- (Read only)
U8
-
onboard EtherCAT - status
- (Read only)
U16
-
●
onboard EtherCAT - Error
- (Read only)
U16
1
-
Device: Ethernet commands: Device: Start firmware update
Off / ready [0]
U8
C
0x2450
Engineering port control
No action/No error [0]
U8
-
0x2451:001
Engineering port settings: IP address
0.0.0.0
U32
E
0x2451:002
Engineering port settings: Subnet
0.0.0.0
U32
E
0x2451:003
Engineering port settings: Gateway
0.0.0.0
U32
E
0x2451:004
Engineering port settings: DHCP
Enabled [1]
U8
-
0x2451:007
Engineering port settings: DNS server address
0.0.0.0
U32
E
0x2452:001
Active engineering port settings: IP address
- (Read only)
U32
E
0x2452:002
Active engineering port settings: Subnet
- (Read only)
U32
E
0x2452:003
Active engineering port settings: Gateway
- (Read only)
U32
E
0x2452:004
Active engineering port settings: DHCP
- (Read only)
U8
-
0x2452:005
Active engineering port settings: MAC address
- (Read only)
OCTET[6]
-
0x2452:006
Active engineering port settings: Link status
- (Read only)
U8
-
0x2452:007
Active engineering port settings: DNS server address
- (Read only)
U32
E
0x245A:001
NTP server addresses: Activate NTP server addresses
No action/no error [0]
U8
-
0x245A:002
NTP server addresses: NTP server address 1
0.0.0.0
U32
E
0x245A:003
NTP server addresses: NTP server address 2
0.0.0.0
U32
E
0x245A:004
NTP server addresses: NTP server address 3
0.0.0.0
U32
E
0x245A:005
NTP server addresses: NTP server address 4
0.0.0.0
U32
E
0x245A:006
NTP server addresses: NTP server name 1
STRING[253]
-
0x245A:007
NTP server addresses: NTP server name 2
STRING[253]
-
0x245A:008
NTP server addresses: NTP server name 3
STRING[253]
-
0x245A:009
NTP server addresses: NTP server name 4
STRING[253]
-
0x245B:001
System time: Setting method
NTP server [0]
U8
-
0x245B:002
System time: Current time
 ns
U64
1
T
Touch probe filter time
0
U16
1
-
Hardware-Diagnose: External supply voltage
x.x V (Read only)
U16
10
-
Hardware-Diagnose: Control board temperature
x.x °C (Read only)
I16
10
-
Mains settings: Rated mains voltage
400 Veff [1]
U8
-
Mains settings: Undervoltage warning threshold
430 V
U16
1
-
Mains settings: Undervoltage error threshold
x V (Read only)
U16
1
-
Mains settings: Undervoltage reset threshold
x V (Read only)
U16
1
-
Mains settings: Overvoltage warning threshold
795 V
U16
1
-
Mains settings: Overvoltage error threshold
x V (Read only)
U16
1
-
Mains settings: Overvoltage reset threshold
x V (Read only)
U16
1
-
Mains settings: DC link voltage critical
- (Read only)
U8
1
-
●
Distributed Clocks: Real time status
- (Read only)
U8
-
Distributed Clocks: First setting time
x ns (Read only)
U64
1
T
Distributed Clocks: Newest setting time
x ns (Read only)
U64
1
T
Distributed Clocks: Current time
x ns (Read only)
U64
1
T
0x2581:001
Application synchronization: Sync - Source
onboard EtherCAT [1]
U8
-
0x2581:002
Application synchronization: Sync - Status
- (Read only)
U8
-
0x2581:005
Application synchronization: Sync - Active cycle time
- (Read only)
U32
1
-
0x2590:003
Energy saving: State of actual energy saving mode
- (Read only)
U8
H
Favorites settings: Parameter 1
 
U32
1
-
Favorites settings: Parameter 2
 
U32
1
-
Favorites settings: Parameter 3
 
U32
1
-
Favorites settings: Parameter 4
 
U32
1
-
Favorites settings: Parameter 5
 
U32
1
-
Favorites settings: Parameter 6
 
U32
1
-
Favorites settings: Parameter 7
 
U32
1
-
Favorites settings: Parameter 8
 
U32
1
-
Favorites settings: Parameter 9
 
U32
1
-
Favorites settings: Parameter 10
 
U32
1
-
Favorites settings: Parameter 11
 
U32
1
-
Favorites settings: Parameter 12
 
U32
1
-
Favorites settings: Parameter 13
 
U32
1
-
Favorites settings: Parameter 14
 
U32
1
-
Favorites settings: Parameter 15
 
U32
1
-
Favorites settings: Parameter 16
 
U32
1
-
Favorites settings: Parameter 17
 
U32
1
-
Favorites settings: Parameter 18
 
U32
1
-
Favorites settings: Parameter 19
 
U32
1
-
Favorites settings: Parameter 20
 
U32
1
-
Favorites settings: Parameter 21
 
U32
1
-
Favorites settings: Parameter 22
 
U32
1
-
Favorites settings: Parameter 23
 
U32
1
-
Favorites settings: Parameter 24
 
U32
1
-
Favorites settings: Parameter 25
 
U32
1
-
Favorites settings: Parameter 26
 
U32
1
-
Favorites settings: Parameter 27
 
U32
1
-
Favorites settings: Parameter 28
 
U32
1
-
Favorites settings: Parameter 29
 
U32
1
-
Favorites settings: Parameter 30
 
U32
1
-
Favorites settings: Parameter 31
 
U32
1
-
Favorites settings: Parameter 32
 
U32
1
-
Favorites settings: Parameter 33
 
U32
1
-
Favorites settings: Parameter 34
 
U32
1
-
Favorites settings: Parameter 35
 
U32
1
-
Favorites settings: Parameter 36
 
U32
1
-
Favorites settings: Parameter 37
 
U32
1
-
Favorites settings: Parameter 38
 
U32
1
-
Favorites settings: Parameter 39
 
U32
1
-
Favorites settings: Parameter 40
 
U32
1
-
Favorites settings: Parameter 41
 
U32
1
-
Favorites settings: Parameter 42
 
U32
1
-
Favorites settings: Parameter 43
 
U32
1
-
Favorites settings: Parameter 44
 
U32
1
-
Favorites settings: Parameter 45
 
U32
1
-
Favorites settings: Parameter 46
 
U32
1
-
Favorites settings: Parameter 47
 
U32
1
-
Favorites settings: Parameter 48
 
U32
1
-
Favorites settings: Parameter 49
 
U32
1
-
Favorites settings: Parameter 50
 
U32
1
-
Inversion of digital inputs: Digital input 1
Not inverted [0]
U8
-
Inversion of digital inputs: Digital input 2
Not inverted [0]
U8
-
Digital input debounce time: Digital input 1
0 ms
U8
1
-
Digital input debounce time: Digital input 2
0 ms
U8
1
-
Digital inputs internal control: Activation
Off [0]
U8
-
Digital inputs internal control: DI1 internal control
Off [0]
U8
-
Digital inputs internal control: DI2 internal control
Off [0]
U8
-
Holding brake control: Brake mode
Off [2]
U8
-
●
Holding brake control: Brake closing time
100 ms
U16
1
-
Holding brake control: Brake opening time
100 ms
U16
1
-
Holding brake control: Brake detection
- (Read only)
U16
-
Holding brake control: Brake polarity
Normal [0]
U8
-
Holding brake control: Brake error response
Fault [1]
U8
-
Holding brake control: Starting torque source
Torque in 0x2820:010 [1]
U16
-
Holding brake control: Starting torque
0.0 %
I16
10
-
●
Holding brake control: Override of the brake control
No override active [0]
U8
-
●
Holding brake control: Holding load ramptime
0 ms
U16
1
-
Holding brake control: Brake status
- (Read only)
U8
-
Holding brake control: Brake opening time test signal
500 ms
U16
1
-
Holding brake control: Brake control word
0x00
U8
H
Holding brake control: Detected actual torque
x.x % (Read only)
I16
10
-
Holding brake control: Holding brake supply voltage
No reduction [100]
U8
-
Holding brake control: Control configuration
Via internal brake module [0]
U8
-
Axis commands: Enable inverter
Inverter enabled [1]
U8
-
0x2822:003
Axis commands: Reset error
Off/Ready [0]
U8
-
0x2822:013
Axis commands: Calculate current controller parameter
Off/Ready [0]
U8
-
0x2822:014
Axis commands: Calculate speed controller parameter
Off/Ready [0]
U8
-
Axis commands: Calculate position controller parameter
Off/Ready [0]
U8
-
0x2822:016
Axis commands: Calculate field controller parameter
Off/Ready [0]
U8
-
0x2822:017
Axis commands: Calculate field weakening controller parameter
Off/Ready [0]
U8
-
Axis commands: Calculate Imin controller parameter
Off/Ready [0]
U8
-
0x2822:019
Axis commands: Calculate Imax controller parameter
Off/Ready [0]
U8
-
0x2822:020
Axis commands: Calculate flying restart circuit controller parameter
Off/Ready [0]
U8
-
Axis commands: Load default Lh saturation characteristic
Off/Ready [0]
U8
-
Axis commands: Load default inverter characteristic
Off/Ready [0]
U8
-
Axis commands: Estimate optimum magnetizing current
Off/Ready [0]
U8
-
0x2822:024
Axis commands: Estimate basic motor parameters based on rated data
Off/Ready [0]
U8
-
Axis commands: Get motor encoder characteristic (resolver)
Off/Ready [0]
U8
-
Axis commands: Get motor encoder information (HIPERFACE®)
Off/Ready [0]
U8
-
0x2822:027
Axis commands: Calculate SLVC controller parameter
Off/Ready [0]
U8
-
Axis commands: Estimate all motor parameters based on rated data
Off/Ready [0]
U8
-
Axis commands: HIPERFACE (A): Set position with synchronization
Off/Ready [0]
U8
-
0x2822:042
Axis commands: Calculate speed filter time constant
Off/Ready [0]
U8
-
0x2822:043
Axis commands: Load power dependent motor parameters
Off/Ready [0]
U8
-
0x2822:044
Axis commands: Cogging torque compensation
Off/Ready [0]
U8
-
Status of axis commands
x % (Read only)
U8
1
-
0x2824
Control selection
Keypad [1]
U8
C
Drive mode selection
CiA402 operating modes [0]
U8
C
Timeout for error response
4 s
U32
1
-
Status words: Cause of disable
- (Read only)
U32
H
●
Status words: Extended status word
- (Read only)
U16
H
●
I/O diagnostic: Application level of the digital inputs
- (Read only)
U32
H
●
Inverter control word
0x0000
U16
H
●
Inverter status word
- (Read only)
U16
H
●
Identification status
- (Read only)
U16
H
Inverter status word 2
- (Read only)
U16
H
●
Manual test mode: Current setpoint
0 %
I16
1
-
●
Manual test mode: Frequency
0.0 Hz
I16
10
-
●
Manual test mode: Starting angle
0.0 °
I16
10
-
Manual control mode: Current setpoint
30 %
U16
1
-
●
Manual control mode: Frequency
0.0 Hz
I16
10
-
●
Manual control mode: Ramp time (current)
0 ms
U16
1
-
Manual control mode: Ramp time (frequency)
500 ms
U16
1
-
Manual control mode: Time monitoring (frequency)
2500 ms
U32
1
-
Manual control mode: Current controller gain
20.00 V/A
U32
100
-
Manual control mode: Current controller reset time
20.00 ms
U32
100
-
Frequency analysis: Period time
1 ms [1000]
U16
-
Frequency analysis: Torque/current amplitude
5.0 %
U16
10
-
Frequency analysis: Speed amplitude
50 rpm
U16
1
-
Frequency analysis: Position amplitude
5.0 °
U16
10
-
0x2837:005
Frequency analysis: Type of excitation
PRBS [0]
U8
C
0x2837:006
Frequency analysis: Velocity offset for 0x2825=11
0 rpm
I16
1
C
Error reset time
x ms (Read only)
I32
1
-
Reset error
0
U8
1
-
0x284E:001
Additional error information: Component ID
- (Read only)
U16
1
-
●
Current error
- (Read only)
OCTET[64]
-
0x285A:001
Diagnostic configuration: Alarm suppression
0x0000
U16
H
0x285B:001
onboard EtherCAT monitoring: Watchdog elapsed
Fault > CiA402 [1]
U8
-
0x285B:002
onboard EtherCAT monitoring: EtherCAT role check
Warning [2]
U8
-
Safety interface: Control data
- (Read only)
U32
H
●
Safety interface: Status data
- (Read only)
U32
H
●
Safety interface: I/O status
- (Read only)
U32
H
●
Safety interface bits: STO active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SS1 active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SS2 active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SOS active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SLS1 active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SLS2 active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SLS3 active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SLS4 active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SDIpos active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SDIneg active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SLI active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SSE active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: ES active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: RMS active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SBC active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: MUT active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SLS1 observed
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SLS2 observed
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SLS3 observed
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SLS4 observed
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SMS observed
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SSM within limits
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SDIpos observed
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SDIneg observed
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SLP1 observed
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SLP2 observed
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SLP3 observed
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SLP4 observed
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SCA1 within limits
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SCA2 within limits
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SCA3 within limits
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SCA4 within limits
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: PDSSpos observed
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: PDSSneg observed
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SOS observed
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SBC activated
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SHom active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SHom available
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: Safe speed OK
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: n=0
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: Positive direction
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: Error active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: AIS S-Bus
- (Read only)
BOOLEAN
1
-
Safety interface bits: AIE S-Bus
- (Read only)
BOOLEAN
1
-
Safety interface bits: SHom_Start S-Bus
- (Read only)
BOOLEAN
1
-
Safety interface bits: SHom_Load S-Bus
- (Read only)
BOOLEAN
1
-
S-Bus control data
- (Read only)
U32
H
S-Bus control bits: STO
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SS1
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SS2
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SLS1
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SLS2
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SLS3
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SLS4
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SDIpos
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SDIneg
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: ES
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SLI
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SLP1
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SLP2
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SLP3
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SLP4
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: AIS
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: AIE
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SOS
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: RMS
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SHom_Start
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SHom_Load
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: PDSS
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SSE
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SBC
- (Read only)
BOOLEAN
1
-
●
System
No motor encoder [0]
U8
-
SinCos encoder PPR
1
U16
1
-
Number of resolver pole pairs
1
U8
1
-
0x2878:004
Response time encoder monitoring
50 [50]
U8
-
Safety-HDSL driver state
- (Read only)
U16
H
Safety HDSL online status 1
- (Read only)
U16
H
Safety HDSL online status 2
- (Read only)
U16
H
Safety HDSL Safe summary
- (Read only)
U8
H
Safety HDSL Safe Channel 2 status
- (Read only)
U8
H
Safety HDSL encoder status ENC_ST0
- (Read only)
U8
H
Safety HDSL encoder status ENC_ST1
- (Read only)
U8
H
Safety HDSL encoder status ENC_ST2
- (Read only)
U8
H
Safety HDSL encoder status ENC_ST3
- (Read only)
U8
H
Safety HDSL encoder status ENC_ST4
- (Read only)
U8
H
Safety HDSL encoder status ENC_ST5
- (Read only)
U8
H
Safety HDSL encoder status ENC_ST6
- (Read only)
U8
H
Safety HDSL encoder status ENC_ST7
- (Read only)
U8
H
Safety HDSL encoder ID
- (Read only)
U8
1
-
Mechanical data: Motor mounting direction
Motor rotating CW [0]
U8
-
Speed: Tolerance window (n=0)
5 rpm
U16
1
-
Speed: Tolerance speed comparison
20 rpm
U16
1
-
Speed: Current speed n_safe
x rpm (Read only)
I16
1
-
●
Speed: Internal current speed nSD
x rpm (Read only)
I16
1
-
Speed: Internal current speed nBD
x rpm (Read only)
I16
1
-
Speed: Current speed difference nSD-nBD
x rpm (Read only)
I16
1
-
Position: Tolerance position comparison
8192 incr.
I32
1
-
Position: Current position p_safe
x incr. (Read only)
I32
1
-
●
Position: Internal current position pSD
x incr. (Read only)
I32
1
-
Position: Internal current position pBD
x incr. (Read only)
I32
1
-
Position: Current position difference pSD-pBD
x incr. (Read only)
I32
1
-
SHom_Start: Source
Disabled [0]
U8
-
SHom_Load: Source
S-Bus [13]
U8
-
SHom: Home position
0 incr.
I32
1
-
SHom: Timeout
0 ms
U16
1
-
SHom: SLS for homing
SLS1 [3]
U8
-
SHom: Restart condition
Homing required [0]
U8
-
SHom: Starting position tolerance
0 incr.
I32
1
-
SHom: Status
- (Read only)
U8
-
SHom: Saved position
x incr. (Read only)
I32
1
-
STO Source S-Bus
Disabled [0]
U8
-
STO: Restart
Automatic restart [1]
U8
-
SS1, SS2: Stopping time
0 ms
U16
1
-
SS1, SS2: Ramp monitoring
Disabled [0]
U8
-
SS1, SS2: Ramp - Smoothing time
0 %
U8
1
-
SS1, SS2: Ramp - Offset mode
Relativ [0]
U8
-
SS1, SS2: Ramp - Start-offset relative
5 %
U8
1
-
SS1, SS2: Ramp - Start-offset absolute
0 rpm
U16
1
-
SS1, SS2: Ramp - Currently monitored speed
x rpm (Read only)
U16
1
-
SS1, SS2: Ramp - Minimum difference
x rpm (Read only)
I16
1
-
SS1 Source S-Bus
Disabled [0]
U8
-
SS1: Mode
STO after stopping time [0]
U8
-
SS1: Delay STO after n=0
0 ms
U16
1
-
SS2 Source S-Bus
Disabled [0]
U8
-
SS2: Mode
SOS after stopping time [0]
U8
-
SOS Source S-Bus
Disabled [0]
U8
-
SOS: Tolerance window (Delta p=0)
8192 incr.
I32
1
-
SOS: Restart
Acknowledged restart [0]
U8
-
SOS: Maximum change of position
x incr. (Read only)
I32
1
-
SSE Source S-Bus
Disabled [0]
U8
-
SSE: Emergency stop function
STO [0]
U8
-
RMS Source
Disabled [0]
U8
-
RMS: Stop function
STO [0]
U8
-
ES Source
Disabled [0]
U8
-
SMS: Maximum speed Nmax
0 rpm
U16
1
-
SMS: Response (n>Nmax)
STO [0]
U8
-
SSM: Monitored speed
0 rpm
U16
1
-
SDI: SDIpos - Source S-Bus
Disabled [0]
U8
-
SDI: SDIneg - Source S-Bus
Disabled [0]
U8
-
SDI: Monitoring standard operation
Both directions enabled [0]
U8
-
SDI: Delay time
0 ms
U16
1
-
SDI: Tolerance threshold
8192 incr.
I32
1
-
SDI: Error response
STO [0]
U8
-
SDI: Maximum change of position
x incr. (Read only)
I32
1
-
SLS: SLS1 - Internal source
Disabled [0]
U32
-
SLS: SLS1 - Internal source inversion
Not inverted [0]
U8
-
SLS: SLS2 - Internal source
Disabled [0]
U32
-
SLS: SLS2 - Internal source inversion
Not inverted [0]
U8
-
SLS: SLS3 - Internal source
Disabled [0]
U32
-
SLS: SLS3 - Internal source inversion
Not inverted [0]
U8
-
SLS: SLS4 - Internal source
Disabled [0]
U32
-
SLS: SLS4 - Internal source inversion
Not inverted [0]
U8
-
SLS: SLS1 - Source S-Bus
Disabled [0]
U8
-
SLS: SLS2 - Source S-Bus
Disabled [0]
U8
-
SLS: SLS3 - Source S-Bus
Disabled [0]
U8
-
SLS: SLS4 - Source S-Bus
Disabled [0]
U8
-
SLS: SLS1 - Limited speed Nlim1
0 rpm
U16
1
-
SLS: SLS2 - Limited speed Nlim2
0 rpm
U16
1
-
SLS: SLS3 - Limited speed Nlim3
0 rpm
U16
1
-
SLS: SLS4 - Limited speed Nlim4
0 rpm
U16
1
-
SLS: SLS1 - Braking time Nlim1
0 ms
U16
1
-
SLS: SLS2 - Braking time Nlim2
0 ms
U16
1
-
SLS: SLS3 - Braking time Nlim3
0 ms
U16
1
-
SLS: SLS4 - Braking time Nlim4
0 ms
U16
1
-
SLS: SLS1 - Permitted direction
Both directions enabled [0]
U8
-
SLS: SLS2 - Permitted direction
Enable both directions [0]
U8
-
SLS: SLS3 - Permitted direction
Enable both directions [0]
U8
-
SLS: SLS4 - Permitted direction
Enable both directions [0]
U8
-
SLS: SLS1 - Response (n>Nlim1)
STO [0]
U8
-
SLS: SLS2 - Response (n>Nlim2)
STO [0]
U8
-
SLS: SLS3 - Response (n>Nlim3)
STO [0]
U8
-
SLS: SLS4 - Response (n>Nlim4)
STO [0]
U8
-
SLI Source S-Bus
Disabled [0]
U8
-
SLI: Increment size standard operation
0 incr.
I32
1
-
SLI: Error response standard operation
STO [0]
U8
-
SLI: Maximum change of position
x incr. (Read only)
I32
1
-
SLP: SLP1 - Source S-Bus
Disabled [0]
U8
-
SLP: SLP2 - Source S-Bus
Disabled [0]
U8
-
SLP: SLP3 - Source S-Bus
Disabled [0]
U8
-
SLP: SLP4 - Source S-Bus
Disabled [0]
U8
-
SLP: SLP1 - Lower position limit
0 incr.
I32
1
-
SLP: SLP2 - Lower position limit
0 incr.
I32
1
-
SLP: SLP3 - Lower position limit
0 incr.
I32
1
-
SLP: SLP4 - Lower position limit
0 incr.
I32
1
-
SLP: SLP1 - Upper position limit
0 incr.
I32
1
-
SLP: SLP2 - Upper position limit
0 incr.
I32
1
-
SLP: SLP3 - Upper position limit
0 incr.
I32
1
-
SLP: SLP4 - Upper position limit
0 incr.
I32
1
-
SLP: SLP1 - Error response
STO [0]
U8
-
SLP: SLP2 - Error response
STO [0]
U8
-
SLP: SLP3 - Error response
STO [0]
U8
-
SLP: SLP4 - Error response
STO [0]
U8
-
SCA: SCA1 - Lower position limit
0 incr.
I32
1
-
SCA: SCA2 - Lower position limit
0 incr.
I32
1
-
SCA: SCA3 - Lower position limit
0 incr.
I32
1
-
SCA: SCA4 - Lower position limit
0 incr.
I32
1
-
SCA: SCA1 - Upper position limit
0 incr.
I32
1
-
SCA: SCA2 - Upper position limit
0 incr.
I32
1
-
SCA: SCA3 - Upper position limit
0 incr.
I32
1
-
SCA: SCA4 - Upper position limit
0 incr.
I32
1
-
PDSS Source S-Bus
Disabled [0]
U8
-
PDSS: Permanent activation
On demand [0]
U8
-
PDSS: Lower position limit
0 incr.
I32
1
-
PDSS: Upper position limit
0 incr.
I32
1
-
PDSS: Lower SCS limit
0 incr.
I32
1
-
PDSS: Upper SCS limit
0 incr.
I32
1
-
PDSS: SCS from lower limit
0 rpm
U16
1
-
PDSS: SCS from upper limit
0 rpm
U16
1
-
PDSS: Maximum speed
0 rpm
U16
1
-
PDSS: Maximum deceleration lower limit
0
U16
1
-
PDSS: Maximum deceleration upper limit
0
U16
1
-
PDSS: Error response
STO [0]
U8
-
PDSS: Currently monitored speed
x rpm (Read only)
U16
1
-
PDSS: Minimum difference monitored speed
x rpm (Read only)
I16
1
-
SBC Source S-Bus
Disabled [0]
U8
-
SBC: Brake mode
SBC without STO [1]
U8
-
SBC: Delay SBC
0 ms
U16
1
-
SBC: Delay STO
0 ms
U16
1
-
SBC: Brake open delay
0 ms
U16
1
-
Diagnostic: Configuration diagnostic value 1
PDSS - Current monitored speed [1]
U16
-
Diagnostic: Configuration diagnostic value 2
SS1, SS2 - Current speed ramp [2]
U16
-
Diagnostic: Diagnostic value 1
- (Read only)
I16
1
-
●
Diagnostic: Diagnostic value 2
- (Read only)
I16
1
-
●
Speed controller settings: Gain
0.00033 Nm/rpm
U32
100000
-
Speed controller settings: Reset time
17.6 ms
U16
10
-
Speed controller settings: Rate time
0.00 ms
U16
100
-
Speed controller gain adaption
100.00 %
U16
100
-
●
I component load value
0.0 %
I16
10
-
●
Speed setpoint filter time
0.0 ms
U16
10
-
Actual speed filter time
0.3 ms
U16
10
-
Additional speed limitation
0 rpm
U32
1
-
●
Inertia settings: Motor moment of inertia
0.14 kg cm²
U32
100
-
Inertia settings: Scaled load inertia
0.00 kg cm²
U32
100
-
Inertia settings: Coupling
Stiff [0]
U8
-
Inertia settings: Mechanical natural frequency
0.0 Hz
U16
10
-
Inertia settings: Load moment of inertia (elastic coupled)
0.00 kg cm²
U32
100
-
Following error diagnostics: Following error (interval) - Time
1000 ms
U16
1
-
Following error diagnostics: Following error (interval) - Mean value
x.xx ° (Read only)
U32
100
-
Following error diagnostics: Following error (interval) - Maximum value
x.xx ° (Read only)
U32
100
-
Following error diagnostics: Following error (manual) - Start/Stop
Stop [0]
U8
-
Following error diagnostics: Following error (manual) - Mean value
x.xx ° (Read only)
U32
100
-
Following error diagnostics: Following error (manual) - Maximum value
x.xx ° (Read only)
U32
100
-
Following error diagnostics: Following error (standstill-standstill) - Mean value
x.xx ° (Read only)
U32
100
-
Following error diagnostics: Following error (standstill-standstill) - Maximum value
x.xx ° (Read only)
U32
100
-
0x2923:001
Activation
Off [0]
U8
C
0x2923:002
Type of load
Simple speed load [0]
U8
-
0x2923:003
Set load torque
0.0 %
I16
10
-
●
0x2923:004
Set load speed
0 rpm
I32
480000/2147483647
-
●
0x2923:005
Load moment of inertia
0.00 kg cm²
U32
100
-
0x2923:006
Friction coefficient
1.0 %
U32
10
-
0x2923:010
Identified total ramp-up time
0.000 ms
U32
1000
-
0x2923:011
Identified factor
1.000000
I32
1000000
-
0x2923:012
Identified current control - delay time
0.0
I32
10
-
0x2923:013
Identified current control - T1
0.0
I32
10
-
0x2923:014
Identified current control - T2
0.0
I32
10
-
0x2923:017
Identified root 1 - real part
0.000 1/s
I32
1000
-
0x2923:018
Identified root 1 - imaginary part
0.000 1/s
I32
1000
-
0x2923:019
Identified root 2 - real part
0.000 1/s
I32
1000
-
0x2923:020
Identified root 2 - imaginary part
0.000 1/s
I32
1000
-
0x2923:021
Identified root 3 - real part
0.000 1/s
I32
1000
-
0x2923:022
Identified root 3 - imaginary part
0.000 1/s
I32
1000
-
0x2923:023
Identified root 4 - real part
0.000 1/s
I32
1000
-
0x2923:024
Identified root 4 - imaginary part
0.000 1/s
I32
1000
-
0x2923:029
Identified pole 1 - real part
0.000 1/s
I32
1000
-
0x2923:030
Identified pole 1 - imaginary part
0.000 1/s
I32
1000
-
0x2923:031
Identified pole 2 - real part
0.000 1/s
I32
1000
-
0x2923:032
Identified pole 2 - imaginary part
0.000 1/s
I32
1000
-
0x2923:033
Identified pole 3 - real part
0.000 1/s
I32
1000
-
0x2923:034
Identified pole 3 - imaginary part
0.000 1/s
I32
1000
-
0x2923:035
Identified pole 4 - real part
0.000 1/s
I32
1000
-
0x2923:036
Identified pole 4 - imaginary part
0.000 1/s
I32
1000
-
0x2923:050
Identified result - motor moment of inertia
0.00 kg cm²
U32
100
-
0x2923:051
Identified result - load 1 moment of inertia
0.00 kg cm²
U32
100
-
0x2923:052
Identified result - load 2 moment of inertia
0.00 kg cm²
U32
100
-
0x2923:054
Identified result - coupling between motor and load 1
0.00
U32
100
-
0x2923:055
Identified result - coupling between load 1 and load 2
0.00
U32
100
-
0x2923:057
Identified result - damping between motor and load 1
0.00
U32
100
-
0x2923:058
Identified result - damping between load 1 and load 2
0.00
U32
100
-
Switching frequency
4 kHz fixed / drive-optimised [6]
U8
-
Current controller feedforward control
Disable [0]
U8
-
Current controller parameters: Gain
148.21 V/A
U32
100
-
Current controller parameters: Reset time
3.77 ms
U32
100
-
Current setpoint filter time
0.00 ms
U16
100
-
Torque setpoint notch filter: Frequency notch filter 1
200.0 Hz
U16
10
-
Torque setpoint notch filter: Bandwidth notch filter 1
20.0 Hz
U16
10
-
Torque setpoint notch filter: Damping notch filter 1
0 dB
U8
1
-
Torque setpoint notch filter: Frequency notch filter 2
400.0 Hz
U16
10
-
Torque setpoint notch filter: Bandwidth notch filter 2
40.0 Hz
U16
10
-
Torque setpoint notch filter: Damping notch filter 2
0 dB
U8
1
-
Torque setpoint jerk limitation
400.0
U16
10
-
Speed limitation: Upper speed limit
0 rpm
I32
480000/2147483647
-
●
Speed limitation: Lower speed limit
0 rpm
I32
480000/2147483647
-
●
Inverter characteristic: Value y1
0.00 V
U16
100
-
Inverter characteristic: Value y2
0.00 V
U16
100
-
Inverter characteristic: Value y3
0.00 V
U16
100
-
Inverter characteristic: Value y4
0.00 V
U16
100
-
Inverter characteristic: Value y5
0.00 V
U16
100
-
Inverter characteristic: Value y6
0.00 V
U16
100
-
Inverter characteristic: Value y7
0.00 V
U16
100
-
Inverter characteristic: Value y8
0.00 V
U16
100
-
Inverter characteristic: Value y9
0.00 V
U16
100
-
Inverter characteristic: Value y10
0.00 V
U16
100
-
Inverter characteristic: Value y11
0.00 V
U16
100
-
Inverter characteristic: Value y12
0.00 V
U16
100
-
Inverter characteristic: Value y13
0.00 V
U16
100
-
Inverter characteristic: Value y14
0.00 V
U16
100
-
Inverter characteristic: Value y15
0.00 V
U16
100
-
Inverter characteristic: Value y16
0.00 V
U16
100
-
Inverter characteristic: Value y17
0.00 V
U16
100
-
Torque limits offset: Torque offset
0.0 %
I16
10
-
Torque limits offset: Resulting positive torque limit
x.x % (Read only)
I16
10
-
Torque limits offset: Resulting negative torque limit
x.x % (Read only)
I16
10
-
Position controller gain
28.40 1/s
U32
100
-
Position controller gain adaption
100.00 %
U16
100
-
●
Position controller output signal limitation
480000.00 rpm
U32
480000/2147483647
-
●
Actual position start value
0
I32
1
-
●
Mode for setting the actual position
Absolute [0]
U8
-
Gain characteristic adaptions: Speed setpoint 1
10 rpm
U16
1
-
Gain characteristic adaptions: Gain adaption 1
100 %
U16
1
-
Gain characteristic adaptions: Speed setpoint 2
100 rpm
U16
1
-
Gain characteristic adaptions: Gain adaption 2
100 %
U16
1
-
Gain characteristic adaptions: Speed setpoint 3
1000 rpm
U16
1
-
Gain characteristic adaptions: Gain adaption 3
100 %
U16
1
-
Gain characteristic adaptions: Speed setpoint 4
2000 rpm
U16
1
-
Gain characteristic adaptions: Gain adaption 4
100 %
U16
1
-
Gain characteristic adaptions: Speed setpoint 5
5000 rpm
U16
1
-
Gain characteristic adaptions: Gain adaption 5
100 %
U16
1
-
Gain characteristic adaptions: Gain characteristic adaption on/off
Off [0]
U8
-
Resulting gain adaption
x.xx % (Read only)
U32
100
-
Field controller settings: Gain
165.84 A/Vs
U32
100
-
Field controller settings: Reset time
15.1 ms
U16
10
-
Field weakening controller settings: Gain (ASM)
0.000 Vs/V
U32
1000
-
Field weakening controller settings: Reset time (ASM)
2000.0 ms
U32
10
-
Field weakening controller Field limitation
100.00 %
U16
100
-
●
DC-bus filter time
25.0 ms
U16
10
-
Motor voltage filter time
25.0 ms
U16
10
-
Voltage reserve range
5 %
U8
1
-
V/f characteristic shape
Linear [0]
U8
C
V/f shape data: Base voltage
225 V
U16
1
-
V/f shape data: Base frequency
270 Hz
U16
1
-
Frequency grid points (x) user V/f characteristic: x1 = f01
-50 Hz
I16
1
-
Frequency grid points (x) user V/f characteristic: x2 = f02
-40 Hz
I16
1
-
Frequency grid points (x) user V/f characteristic: x3 = f03
-30 Hz
I16
1
-
Frequency grid points (x) user V/f characteristic: x4 = f04
-20 Hz
I16
1
-
Frequency grid points (x) user V/f characteristic: x5 = f05
-10 Hz
I16
1
-
Frequency grid points (x) user V/f characteristic: x6 = f06
0 Hz
I16
1
-
Frequency grid points (x) user V/f characteristic: x7 = f07
10 Hz
I16
1
-
Frequency grid points (x) user V/f characteristic: x8 = f08
20 Hz
I16
1
-
Frequency grid points (x) user V/f characteristic: x9 = f09
30 Hz
I16
1
-
Frequency grid points (x) user V/f characteristic: x10 = f10
40 Hz
I16
1
-
Frequency grid points (x) user V/f characteristic: x11 = f11
50 Hz
I16
1
-
Voltage grid points (y) user V/f characteristic: y1 = U01 (x = f01)
400.00 V
U32
100
-
Voltage grid points (y) user V/f characteristic: y2 = U02 (x = f02)
320.00 V
U32
100
-
Voltage grid points (y) user V/f characteristic: y3 = U03 (x = f03)
240.00 V
U32
100
-
Voltage grid points (y) user V/f characteristic: y4 = U04 (x = f04)
160.00 V
U32
100
-
Voltage grid points (y) user V/f characteristic: y5 = U05 (x = f05)
80.00 V
U32
100
-
Voltage grid points (y) user V/f characteristic: y6 = U06 (x = f06)
0.00 V
U32
100
-
Voltage grid points (y) user V/f characteristic: y7 = U07 (x = f07)
80.00 V
U32
100
-
Voltage grid points (y) user V/f characteristic: y8 = U08 (x = f08)
160.00 V
U32
100
-
Voltage grid points (y) user V/f characteristic: y9 = U09 (x = f09)
240.00 V
U32
100
-
Voltage grid points (y) user V/f characteristic: y10 = U10 (x = f10)
320.00 V
U32
100
-
Voltage grid points (y) user V/f characteristic: y11 = U11 (x = f11)
400.00 V
U32
100
-
V/f boost controller - current setpoint
0.00 A
U32
100
-
V/f boost controller settings: Gain
148.21 V/A
U32
100
-
V/f boost controller settings: Reset time
3.77 ms
U32
100
-
V/f boost controller settings: Dynamic current setpoint
0.00 A
U32
100
-
Voltage boost
0.0 V
U16
10
-
Load adaption: Direction of rotation
Passive load [0]
U8
C
Load adaption: Load adaption value
20.00 %
U32
100
-
V/f Imax controller: Gain
0.001 Hz/A
U32
1000
-
V/f Imax controller: Reset time
100.0 ms
U32
10
-
Slip compensation: Gain
0.00 %
I16
100
-
Slip compensation: Filter time
2000 ms
U16
1
-
Oscillation damping: Gain
20 %
I16
1
-
Oscillation damping: Filter time
5 ms
U16
1
-
Oscillation damping: Limitation
0.2 Hz
U16
10
-
Oscillation damping: Final ramp frequency
0 %
U8
1
-
Ramp generator frequency
x.x Hz (Read only)
I16
10
-
●
Override field weakening
0.0 Hz
I16
10
-
Gain
0.100
U16
1000
-
Reset time
100.0 ms
U16
10
-
Frequency limitation
10.00 Hz
U16
100
-
SLVC: Gain
0.0010 Hz/A
U32
10000
-
SLVC: Reset time
100.0 ms
U32
10
-
SLVC: Q-Feedforward
0.00
U32
100
-
SLVC: D-Feedforward
0.00
U32
100
-
Current for DC-injection braking
0.00 A
U16
100
-
Activate flying restart
Off [0]
U8
-
Flying restart circuit
15 %
U16
1
-
Start frequency
20.0 Hz
I16
10
-
Integration time
600 ms
U16
1
-
Minimum deviation
5.00 °
U16
100
-
Delay time
0 ms
U16
1
-
Result: Determined speed [rpm]
x rpm (Read only)
I16
1
-
●
Result: Determined speed [n unit]
rpm (Read only)
I32
480000/2147483647
-
●
Motor control mode
Servoregelung (SC-PSM) [1]
U8
C
Motor parameters: Number of pole pairs
- (Read only)
U8
1
-
Motor parameters: Stator resistance
13.5000 Ω
U32
10000
-
Motor parameters: Stator leakage inductance
51.000 mH
U32
1000
-
Motor parameters: Rated speed
4050 rpm
U16
1
-
Motor parameters: Rated frequency
270.0 Hz
U16
10
-
Motor parameters: Rated power
0.25 kW
U16
100
-
Motor parameters: Rated voltage
225 V
U16
1
-
Motor parameters: Cosine phi
0.80
U16
100
-
Motor parameters: Insulation class
F (cut-off temperature = 155 °C) [4]
U8
-
Motor parameters: Motor name
"MCS06C41"
STRING[50]
-
Motor parameter (ASM): Rotor resistance
0.0000 Ω
U32
10000
-
Motor parameter (ASM): Mutual inductance
0.0 mH
U32
10
-
Motor parameter (ASM): Magnetising current
0.00 A
U16
100
-
Motor parameter (PSM): Back EMF constant
41.8 V/1000rpm
U32
10
-
Motor parameter (PSM): Resolver pole position
-90.0 °
I16
10
-
Motor parameter (PSM): Magnets temperature coefficient (kTN)
-0.110 %/°C
I16
1000
-
Motor parameter (PSM): Encoder pole position
0.0 °
I16
10
-
d-axis Lss saturation characteristic: y1 = L01 (x = 0.00 %)
165 %
U16
1
-
d-axis Lss saturation characteristic: y2 = L02 (x = 6.25 %)
200 %
U16
1
-
d-axis Lss saturation characteristic: y3 = L03 (x = 12.50 %)
146 %
U16
1
-
d-axis Lss saturation characteristic: y4 = L04 (x = 18.75 %)
117 %
U16
1
-
d-axis Lss saturation characteristic: y5 = L05 (x = 25.00 %)
97 %
U16
1
-
d-axis Lss saturation characteristic: y6 = L06 (x = 31.25 %)
82 %
U16
1
-
d-axis Lss saturation characteristic: y7 = L07 (x = 37.50 %)
71 %
U16
1
-
d-axis Lss saturation characteristic: y8 = L08 (x = 42.75 %)
62 %
U16
1
-
d-axis Lss saturation characteristic: y9 = L09 (x = 50.00 %)
55 %
U16
1
-
d-axis Lss saturation characteristic: y10 = L10 (x = 56.25 %)
50 %
U16
1
-
d-axis Lss saturation characteristic: y11 = L11 (x = 62.50 %)
46 %
U16
1
-
d-axis Lss saturation characteristic: y12 = L12 (x = 68.75 %)
43 %
U16
1
-
d-axis Lss saturation characteristic: y13 = L13 (x = 75.00 %)
42 %
U16
1
-
d-axis Lss saturation characteristic: y14 = L14 (x = 81.25 %)
41 %
U16
1
-
d-axis Lss saturation characteristic: y15 = L15 (x = 87.50 %)
41 %
U16
1
-
d-axis Lss saturation characteristic: y16 = L16 (x = 93.25 %)
41 %
U16
1
-
d-axis Lss saturation characteristic: y17 = L17 (x = 100.00 %)
41 %
U16
1
-
d-axis Lss saturation characteristic: Activation Lss saturation characteristic
Adjustment on [1]
U16
-
0x2C04:019
d-axis Lss saturation characteristic: Cross saturation factor
0 %
U16
1
-
Reference for current grid points (x) Lss saturation characteristic
5.4 A
U16
10
-
Grid points for magnet characteristic (current): x1 = i01/iN
0 %
U16
1
-
Grid points for magnet characteristic (current): y1 = kT01/kTN
100 %
U16
1
-
Grid points for magnet characteristic (current): x2 = i02/iN
100 %
U16
1
-
Grid points for magnet characteristic (current): y2 = kT02/kTN
100 %
U16
1
-
Grid points for magnet characteristic (current): x3 = i03/iN
200 %
U16
1
-
Grid points for magnet characteristic (current): y3 = kT03/kTN
100 %
U16
1
-
Grid points for magnet characteristic (current): x4 = i04/iN
415 %
U16
1
-
Grid points for magnet characteristic (current): y4 = kT04/kTN
72 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y1 = L01 (x = 0.00 %)
118 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y2 = L02 (x = 6.25 %)
118 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y3 = L03 (x = 12.50 %)
118 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y4 = L04 (x = 18.75 %)
117 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y5 = L05 (x = 25.00 %)
116 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y6 = L06 (x = 31.25 %)
114 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y7 = L07 (x = 37.50 %)
111 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y8 = L08 (x = 43.75 %)
107 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y9 = L09 (x = 50.00 %)
100 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y10 = L10 (x = 56.25 %)
93 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y11 = L11 (x = 62.50 %)
86 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y12 = L12 (x = 68.75 %)
78 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y13 = L13 (x = 75.00 %)
71 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y14 = L14 (x = 81.25 %)
64 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y15 = L15 (x = 87.50 %)
57 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y16 = L16 (x = 93.75 %)
50 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y17 = L17 (x = 100.00 %)
42 %
U16
1
-
Method for setting motor parameters
Select from catalogue (Lenze motors) [1]
U8
-
0x2C09:001
q-axis Lss saturation characteristic: y1 = L01 (x = 0.00 %)
165 %
U16
1
-
0x2C09:002
q-axis Lss saturation characteristic: y2 = L02 (x = 6.25 %)
200 %
U16
1
-
0x2C09:003
q-axis Lss saturation characteristic: y3 = L03 (x = 12.50 %)
146 %
U16
1
-
0x2C09:004
q-axis Lss saturation characteristic: y4 = L04 (x = 18.75 %)
117 %
U16
1
-
0x2C09:005
q-axis Lss saturation characteristic: y5 = L05 (x = 25.00 %)
97 %
U16
1
-
0x2C09:006
q-axis Lss saturation characteristic: y6 = L06 (x = 31.25 %)
82 %
U16
1
-
0x2C09:007
q-axis Lss saturation characteristic: y7 = L07 (x = 37.50 %)
71 %
U16
1
-
0x2C09:008
q-axis Lss saturation characteristic: y8 = L08 (x = 42.75 %)
62 %
U16
1
-
0x2C09:009
q-axis Lss saturation characteristic: y9 = L09 (x = 50.00 %)
55 %
U16
1
-
0x2C09:010
q-axis Lss saturation characteristic: y10 = L10 (x = 56.25 %)
50 %
U16
1
-
0x2C09:011
q-axis Lss saturation characteristic: y11 = L11 (x = 62.50 %)
46 %
U16
1
-
0x2C09:012
q-axis Lss saturation characteristic: y12 = L12 (x = 68.75 %)
43 %
U16
1
-
0x2C09:013
q-axis Lss saturation characteristic: y13 = L13 (x = 75.00 %)
42 %
U16
1
-
0x2C09:014
q-axis Lss saturation characteristic: y14 = L14 (x = 81.25 %)
41 %
U16
1
-
0x2C09:015
q-axis Lss saturation characteristic: y15 = L15 (x = 87.50 %)
41 %
U16
1
-
0x2C09:016
q-axis Lss saturation characteristic: y16 = L16 (x = 93.25 %)
41 %
U16
1
-
0x2C09:017
q-axis Lss saturation characteristic: y17 = L17 (x = 100.00 %)
41 %
U16
1
-
0x2C09:018
q-axis Lss saturation characteristic: Table source
Identical to d-axis (0x2C04) [0]
U16
-
High speed range: Lower limit
20 %
U16
1
-
High speed range: Tracking controller gain
250 %
U16
1
-
High speed range: Tracking controller reset time
6.00 ms
U16
100
-
High speed range: Tracking controller decouple time
0.00 ms
U16
100
-
SM low speed range: Acceleration current
100 %
U16
1
-
SM low speed range: Standstill current
20 %
U16
1
-
0x2C16:001
Cogging torque compensation: Enable compensation
On [1]
U8
-
0x2C16:002
Cogging torque compensation: Commutation turns
1
U8
1
-
0x2C16:003
Cogging torque compensation: Max. recommended identification speed
x rpm (Read only)
U16
1
-
0x2C16:005
Cogging torque compensation: Identification state
- (Read only)
U16
H
0x2C16:006
Cogging torque compensation: Amplitude 1
0.000 %
I16
1000
C
0x2C16:007
Cogging torque compensation: Phase 1
0.0 °
I16
10
C
0x2C16:008
Cogging torque compensation: Amplitude 2
0.000 %
I16
1000
C
0x2C16:009
Cogging torque compensation: Phase 2
0.0 °
I16
10
C
0x2C16:010
Cogging torque compensation: Amplitude 3
0.000 %
I16
1000
C
0x2C16:011
Cogging torque compensation: Phase 3
0.0 °
I16
10
C
0x2C16:012
Cogging torque compensation: Amplitude 4
0.000 %
I16
1000
C
0x2C16:013
Cogging torque compensation: Phase 4
0.0 °
I16
10
C
0x2C16:014
Cogging torque compensation: Amplitude 5
0.000 %
I16
1000
C
0x2C16:015
Cogging torque compensation: Phase 5
0.0 °
I16
10
C
0x2C16:016
Cogging torque compensation: Amplitude 6
0.000 %
I16
1000
C
0x2C16:017
Cogging torque compensation: Phase 6
0.0 °
I16
10
C
0x2C16:018
Cogging torque compensation: Amplitude 7
0.000 %
I16
1000
C
0x2C16:019
Cogging torque compensation: Phase 7
0.0 °
I16
10
C
0x2C16:020
Cogging torque compensation: Amplitude 8
0.000 %
I16
1000
C
0x2C16:021
Cogging torque compensation: Phase 8
0.0 °
I16
10
C
0x2C16:022
Cogging torque compensation: Amplitude 9
0.000 %
I16
1000
C
0x2C16:023
Cogging torque compensation: Phase 9
0.0 °
I16
10
C
0x2C16:024
Cogging torque compensation: Amplitude 10
0.000 %
I16
1000
C
0x2C16:025
Cogging torque compensation: Phase 10
0.0 °
I16
10
C
Motor encoder type
SinCos encoder [1]
U8
C
Motor encoder settings (HIPERFACE®): Type code detected
- (Read only)
U8
1
-
Motor encoder settings (HIPERFACE®): Type code manual input
0
U8
1
C
Motor encoder settings (HIPERFACE®): Manual input - Number of detectable motor encoder revolutions
1
U16
1
C
Motor encoder settings (HIPERFACE®): Error response
Fault > CiA402 [1]
U8
-
Motor encoder settings (HIPERFACE®): Serial number
- (Read only)
STRING[50]
-
Motor encoder settings (HIPERFACE®): Actual position (raw data)
- (Read only)
U32
1
-
●
Motor encoder settings (HIPERFACE®): No. of periods detected
- (Read only)
U16
1
-
●
Motor encoder settings (HIPERFACE®): Type code verification
- (Read only)
U8
-
●
Motor encoder settings (HIPERFACE®): Encoder type
- (Read only)
U8
-
●
Motor encoder settings (HIPERFACE®): Period length of linear encoder
x nm (Read only)
U32
1
-
●
Encoder settings: Increments/revolution
1024
U32
1
C
Encoder settings: Supply voltage
5.0 V
U8
10
C
Encoder settings: Angle drift
x.x ° (Read only)
I16
10
-
●
Encoder settings: Actual amplitude signal quality
x % (Read only)
U8
1
-
0x2C42:008
Encoder settings: Encoder voltage cos track
x.xxx V (Read only)
I16
1000
-
0x2C42:009
Encoder settings: Encoder voltage sin track
x.xxx V (Read only)
I16
1000
-
Motor encoder resolver number of pole pairs
1
U8
1
C
Motor encoder identification (Resolver): Angle
0
I16
1
-
Motor encoder identification (Resolver): Cosine track gain
100 %
U16
1
-
Motor encoder identification (Resolver): Sine track gain
100 %
U16
1
-
Motor encoder identification (Resolver): Identification status
- (Read only)
U16
H
Motor encoder identification (Resolver): Cosine track offset
0.000 %
I32
1000
-
Motor encoder identification (Resolver): Sine track offset
0.000 %
I32
1000
-
Motor encoder identification (Resolver): Cyclic online compensation
On [1]
U8
-
Motor encoder identification (Resolver): Harmonic for cyclic online compensation
22
U16
1
-
Motor encoder identification (Resolver): Dead time compensation resolver evaluation
100.0 %
I16
10
-
Motor feedback error response
Warning [1]
U8
-
Number of the absolute ascertainable revolutions of motor encoder
- (Read only)
U16
1
-
Open circuit detection sensitivity of motor encoder
100 %
U8
1
-
0x2C48:001
Motor encoder (EnDat): Response communication error
Warning [1]
U8
-
0x2C48:002
Motor encoder (EnDat): Actual position (raw data)
- (Read only)
U32
1
-
●
0x2C48:003
Motor encoder (EnDat): Serial number
- (Read only)
STRING[50]
-
0x2C48:004
Motor encoder (EnDat): ID number
- (Read only)
STRING[50]
-
0x2C48:005
Motor encoder (EnDat): Encoder designation
- (Read only)
STRING[50]
-
0x2C48:006
Motor encoder (EnDat): EnDat ordering designation
- (Read only)
STRING[50]
-
0x2C48:007
Motor encoder (EnDat): EnDat command set
- (Read only)
STRING[50]
-
0x2C48:008
Motor encoder (EnDat): Encoder type
- (Read only)
U8
1
-
0x2C48:009
Motor encoder (EnDat): Signal periods per revolution/Length of signal period
- (Read only)
U32
1
-
0x2C48:010
Motor encoder (EnDat): Distinguishable revolutions
- (Read only)
U16
1
-
0x2C48:011
Motor encoder (EnDat): Max. clock frequency
x kHz (Read only)
U16
1
-
0x2C48:012
Motor encoder (EnDat): Measuring step or measuring steps/rev for serial data transmission
- (Read only)
U32
1
-
0x2C48:013
Motor encoder (EnDat): Scaling factor for resolution
- (Read only)
U16
1
-
0x2C48:014
Motor encoder (EnDat): Measuring step, or measuring steps/rev or subdivision values of a grating period
- (Read only)
U32
1
-
Motor encoder (SSI) protocol parameters: Bit rate
300 kbps
U16
1
C
Motor encoder (SSI) protocol parameters: Telegram length
25
U8
1
C
Motor encoder (SSI) protocol parameters: Bits/revolution
13
U8
1
C
Motor encoder (SSI) protocol parameters: Position data start bit
0
U8
1
C
Motor encoder (SSI) protocol parameters: Data package 1 start bit
0
U8
1
C
Motor encoder (SSI) protocol parameters: Data package 2 start bit
0
U8
1
C
Motor encoder (SSI) protocol parameters: Data package 3 start bit
0
U8
1
C
Motor encoder (SSI) protocol parameters: Position data length
0
U8
1
C
Motor encoder (SSI) protocol parameters: Data package 1 length
0
U8
1
C
Motor encoder (SSI) protocol parameters: Data package 2 length
0
U8
1
C
Motor encoder (SSI) protocol parameters: Data package 3 length
0
U8
1
C
Motor encoder (SSI) protocol parameters: Position data coding
Binary [0]
U8
C
Motor encoder (SSI) protocol parameters: Data package 1 coding
Binary [0]
U8
C
Motor encoder (SSI) protocol parameters: Data package 2 coding
Binary [0]
U8
C
Motor encoder (SSI) protocol parameters: Data package 3 coding
Binary [0]
U8
C
Motor encoder (SSI) protocol parameters: Position raw data
- (Read only)
U32
1
-
●
Motor encoder (SSI) protocol parameters: Data package 1 raw data
- (Read only)
U32
1
-
●
Motor encoder (SSI) protocol parameters: Data package 2 raw data
- (Read only)
U32
1
-
●
Motor encoder (SSI) protocol parameters: Data package 3 raw data
- (Read only)
U32
1
-
●
Motor encoder (SSI) protocol parameters: Encoder type
Rotative encoder [0]
U8
C
Motor encoder (SSI) protocol parameters: Position raw data scaled by 0x608F
- (Read only)
I32
1
-
●
Motor encoder (SSI) protocol parameters: Monoflop time
0
U16
1
C
Motor encoder (SSI) protocol parameters: Resulting SSI-telegram cycle time
- (Read only)
U16
10
-
Release version
- (Read only)
U8
1
-
Release Date
- (Read only)
U32
1
-
Encoder ID
- (Read only)
U32
1
-
Type of encoder
- (Read only)
U16
1
-
Resolution
- (Read only)
U32
1
-
Measurement range
- (Read only)
U32
1
-
Type name
- (Read only)
STRING[50]
-
Serial number
- (Read only)
STRING[50]
-
Device version
- (Read only)
STRING[50]
-
Firmware date
- (Read only)
STRING[50]
-
EEPROM size
- (Read only)
U16
1
-
Safe Channel 2 Resolution
- (Read only)
U32
1
-
Delay / RSSI
- (Read only)
U8
H
Quality monitoring
- (Read only)
U8
H
Slave RSSI
- (Read only)
U8
H
Supply voltage
x.xxx V (Read only)
U16
1000
-
Rotation speed range
x rpm (Read only)
U16
1
-
Auswahl
No value [0]
U16
-
Value
- (Read only)
I64
1
-
0x2C4B:027
Communication error counter
- (Read only)
U32
1
-
Events
- (Read only)
U16
H
Status summaries
- (Read only)
U8
H
Encoder status, byte 0
- (Read only)
U8
H
Encoder status, byte 1
- (Read only)
U8
H
Encoder status, byte 2
- (Read only)
U8
H
Encoder status, byte 3
- (Read only)
U8
H
Encoder status, byte 4
- (Read only)
U8
H
Encoder status, byte 5
- (Read only)
U8
H
Encoder status, byte 6
- (Read only)
U8
H
Encoder status, byte 7
- (Read only)
U8
H
Fast position
- (Read only)
I64
1
-
Parameter CRC of motor encoder
- (Read only)
U32
1
-
PPI monitoring: Response
Fault [1]
U8
-
Pole position identification (360°) settings: Current amplitude
71 %
U16
1
C
Pole position identification (360°) settings: Ramp time
40 s
U16
1
C
Pole position identification (360°) settings: Direction of rotation
CW [0]
U8
C
Pole position identification (360°) settings: Error tolerance
20 °
U8
1
-
Pole position identification (360°) settings: Absolute current amplitude
x.xx A (Read only)
U32
100
-
0x2C61:006
Pole position identification (360°) settings: ixt threshold for reversal of rotating direction
30 %
U8
1
-
0x2C61:010
Pole position identification (360°) settings: Actual commutation angle
x.xxx ° (Read only)
U32
1000
-
Pole position identification (min. movement) settings: Current amplitude
25 %
U16
1
C
Pole position identification (min. movement) settings: Ramp time
10 s
U16
1
C
Pole position identification (min. movement) settings: Gain
0 %
U16
1
-
Pole position identification (min. movement) settings: Reset time
62.5 ms
U16
10
-
Pole position identification (min. movement) settings: Max. move permitted
20 °
U8
1
-
Pole position identification (min. movement) settings: Absolute current amplitude
x.xx A (Read only)
U32
100
-
PPI without movement: Execution
Disabled [0]
U8
C
PPI without movement: Current adjust factor
100 %
U16
1
C
Cable Check: Behavior after switch on
No action [0]
U8
C
Cable Check: Status word
- (Read only)
U16
H
PPI validation: Activation
Off [0]
U8
C
PPI validation: Settings
No action [0]
U8
-
PPI validation: Status
- (Read only)
U16
H
●
PPI validation: Pole position set value
0.0 °
I16
10
-
PPI mode for 0x6060: Selection
PPI 360° [1]
U8
C
MOL settings for 0x6060: Current setpoint 1
71 %
U16
1
-
MOL settings for 0x6060: Frequency 1
1.0 Hz
I16
10
-
MOL settings for 0x6060: Current 1 - ramp time
10 ms
U16
1
-
MOL settings for 0x6060: Frequency 1 - ramp time
200 ms
U16
1
-
MOL settings for 0x6060: Starting angle 1
0.0 °
I16
10
-
MOL settings for 0x6060: Stopping time 1
10000.0 s
U32
10
C
MOL settings for 0x6060: Current setpoint 2
71 %
U16
1
-
MOL settings for 0x6060: Frequency 2
5.0 Hz
I16
10
-
MOL settings for 0x6060: Current 2 - ramp time
10 ms
U16
1
-
MOL settings for 0x6060: Frequency 2 - ramp time
1000 ms
U16
1
-
MOL settings for 0x6060: Starting angle 2
0.0 °
I16
10
-
MOL settings for 0x6060: Stopping time 2
10000.0 s
U32
10
C
Touch probe (TP) delay time: Touch probe 1 delay time
0.000 ms
U16
1000
-
Touch probe (TP) delay time: Touch probe 2 delay time
0.000 ms
U16
1000
-
Touch probe (TP) time stamp: Touch probe 1-rising edge time stamp
x ns (Read only)
U32
1
-
●
Touch probe (TP) time stamp: Touch probe 1-falling edge time stamp
x ns (Read only)
U32
1
-
●
Touch probe (TP) time stamp: Touch probe 2-rising edge time stamp
x ns (Read only)
U32
1
-
●
Touch probe (TP) time stamp: Touch probe 2-falling edge time stamp
x ns (Read only)
U32
1
-
●
Device utilisation ixt: Power unit actual utilisation
x % (Read only)
U16
1
-
●
Device utilisation ixt: Power unit warning threshold
95 %
U16
1
-
Device utilisation ixt: Power unit error threshold
x % (Read only)
U16
1
-
Device utilisation ixt: Device actual utilisation
x % (Read only)
U16
1
-
●
Device utilisation ixt: Device warning threshold
95 %
U16
1
-
Device utilisation ixt: Device error threshold
x % (Read only)
U16
1
-
Overspeed monitoring: Threshold
8000 rpm
U16
1
-
Overspeed monitoring: Response
Warning [1]
U8
-
Motor phase failure detection: Response - Motor phase 1
No response [0]
U8
-
Motor phase failure detection: Current threshold
5.0 %
U8
10
-
Motor phase failure detection: Voltage threshold
10.0 V
U16
10
-
Motor phase failure detection: Response - Motor phase 2
No response [0]
U8
-
Overcurrent monitoring: Threshold
5.4 A
U16
10
-
Overcurrent monitoring: Response
Warning [1]
U8
-
PTC temperature sensor monitoring: Error response
Fault > CiA402 [1]
U8
-
Motor temperature monitoring: Temperature sensor type
PT1000 [5]
U8
-
Motor temperature monitoring: Response
Warning [1]
U8
-
Motor temperature monitoring: Warning threshold
145.0 °C
I16
10
-
Motor temperature monitoring: Error threshold
155.0 °C
I16
10
-
Motor temperature monitoring: Actual motor temperature
x.x °C (Read only)
I16
10
-
●
Motor temperature monitoring: Spec. characteristic temperature grid point 1
25.0 °C
I16
10
-
Motor temperature monitoring: Spec. characteristic temperature grid point 2
150.0 °C
I16
10
-
Motor temperature monitoring: Spec. characteristic resistance grid point 1
1000 Ω
I16
1
-
Motor temperature monitoring: Spec. characteristic resistance grid point 2
2225 Ω
I16
1
-
Thermal model motor utilization (i²xt): Motor utilisation (i²xt)
60 s
U16
1
-
Thermal model motor utilization (i²xt): Thermal time constant - laminations
852 s
U16
1
-
Thermal model motor utilization (i²xt): Winding influence
27 %
U8
1
-
Thermal model motor utilization (i²xt): Starting value
0 %
U16
1
-
Motor utilisation (i²xt) - specific characteristic: x1 = n01/nN (n01 ~ 0)
0 %
U16
1
-
Motor utilisation (i²xt) - specific characteristic: y1 = i01/iN (x1)
100 %
U16
1
-
Motor utilisation (i²xt) - specific characteristic: x2 = n02/nN (n02 = limit reduced cooling)
0 %
U16
1
-
Motor utilisation (i²xt) - specific characteristic: y2 = i02/iN (x2)
100 %
U16
1
-
Motor utilisation (i²xt) - specific characteristic: x3 = n03/nN (n03 = rated speed)
100 %
U16
1
-
Motor utilisation (i²xt) - specific characteristic: y3 = i03/iN (x3)
100 %
U16
1
-
Motor utilisation (i²xt) - specific characteristic: x4 = n04/nN (n04 = limit field weakening)
100 %
U16
1
-
Motor utilisation (i²xt) - specific characteristic: y4 = i04/iN (x4)
100 %
U16
1
-
Motor utilisation (i²xt) - warning threshold
100 %
U16
1
-
Motor utilisation (i²xt)
x % (Read only)
U16
1
-
●
Motor utilisation (i²xt) - monitoring: Error response
Fehler > CiA402 [1]
U8
-
Motor utilisation (i²xt) - monitoring: Error threshold
105 %
U16
1
-
Position error/speed error - monitoring: Speed error - error threshold
50 rpm
U32
1
-
Position error/speed error - monitoring: Speed error - min. time for error
0 ms
U16
1
-
Position error/speed error - monitoring: Speed error - error response
No response [0]
U8
-
Position error/speed error - monitoring: Position error - error threshold
360 °
U32
1
-
Position error/speed error - monitoring: Position error - min. time for error
0 ms
U16
1
-
Position error/speed error - monitoring: Position error - error response
No response [0]
U8
-
Mains failure control: Enable function
Disabled [0]
U8
-
Mains failure control: DC-bus activation level
75 %
U8
1
-
Mains failure control: Filter time
0.00 s
U16
100
-
Mains failure control: Ramp max. torque
30.0 %
U16
10
-
Mains failure control: Ramp time
1.00 s
U16
100
-
Mains failure control: Actual DC bus voltage (filtered)
x.xxx V (Read only)
U32
1000
-
Life-diagnosis: Operating time
x s (Read only)
U32
1
-
Life-diagnosis: Power-on time
x s (Read only)
U32
1
-
Life-diagnosis: Main switching cycles
- (Read only)
U32
1
-
Life-diagnosis: Short-circuit counter
- (Read only)
U32
1
-
Life-diagnosis: Earth fault counter
- (Read only)
U32
1
-
Life-diagnosis: Fan operating time
x s (Read only)
U32
1
-
Motor actual voltage (Veff)
x.x V (Read only)
U32
10
-
●
Motor-Phasenströme: Zero system current
x.xx A (Read only)
I32
100
-
●
Motor-Phasenströme: Phase U current
x.xx A (Read only)
I32
100
-
●
Motor-Phasenströme: Phase V current
x.xx A (Read only)
I32
100
-
●
Motor-Phasenströme: Phase W current
x.xx A (Read only)
I32
100
-
●
Heatsink temperature: Heatsink temperature
x.x °C (Read only)
I16
10
-
Heatsink temperature: Warning threshold
90.0 °C
I16
10
-
Actual speed error
x rpm (Read only)
I32
1
-
●
Output power: Effective power
x.xxx kW (Read only)
I32
1000
-
●
Output energy: Overall energy
0.00 kWh
I32
100
-
Field values: Actual value
x % (Read only)
U16
1
-
●
Field values: Setpoint value
x % (Read only)
U16
1
-
●
Motor currents: Actual D-current (id)
x.xx A (Read only)
I32
100
-
●
Motor currents: Actual Q-current (iq)
x.xx A (Read only)
I32
100
-
●
Motor currents: Setpoint D-current (id)
x.xx A (Read only)
I32
100
-
●
Motor currents: Setpoint Q-current (iq)
x.xx A (Read only)
I32
100
-
●
Motor currents: Motor current (Ieff)
x.xx A (Read only)
I32
100
-
●
Target position interpolated
- (Read only)
I32
1
-
●
Speed setpoints: Speed setpoint
x rpm (Read only)
I32
1
-
●
Speed setpoints: Speed setpoint 2
x rpm (Read only)
I32
1
-
●
Speed setpoints: Speed setpoint limited
x rpm (Read only)
I32
1
-
●
Speed controller output signals: Output signal 1
x.x % (Read only)
I16
10
-
●
Speed controller output signals: Output signal 2
x.x % (Read only)
I16
10
-
●
Torque setpoint
x.xx Nm (Read only)
I32
100
-
●
Torque filter cascade: Starting value
x.x % (Read only)
I16
10
-
●
Torque filter cascade: Notch filter 1 input value
x.x % (Read only)
I16
10
-
●
Torque filter cascade: Notch filter 2 input value
x.x % (Read only)
I16
10
-
●
Torque filter cascade: Torque setpoint filtered
x.x % (Read only)
I16
10
-
●
Voltage values: Actual voltage (motor voltage limit)
x.x V (Read only)
I16
10
-
●
Voltage values: Output signal D current controller
x.x V (Read only)
I16
10
-
●
Voltage values: Output signal Q current controller
x.x V (Read only)
I16
10
-
●
Voltage values: D voltage (magnetisation)
x.x V (Read only)
I16
10
-
●
Voltage values: Q voltage (torque)
x.x V (Read only)
I16
10
-
●
Voltage values: Phases U-V
x.x V (Read only)
I16
10
-
●
Voltage values: Phases V-W
x.x V (Read only)
I16
10
-
●
Voltage values: Phases W-U
x.x V (Read only)
I16
10
-
●
Voltage values: Phase U
x.x V (Read only)
I16
10
-
●
Voltage values: Phase V
x.x V (Read only)
I16
10
-
●
Voltage values: Phase W
x.x V (Read only)
I16
10
-
●
Actual slip value
x.x Hz (Read only)
I16
10
-
●
Output frequency
x.x Hz (Read only)
I16
10
-
●
Actual rotor angle position
- (Read only)
I16
1
-
●
Axis information: Rated current
x.xx A (Read only)
U16
100
-
●
Axis information: Maximum current
x.xx A (Read only)
U16
100
-
●
Axis information: Detected module in slot A
- (Read only)
U8
-
●
Axis information: Function of X109
- (Read only)
U8
-
●
Service settings: Current controller identification settings
Automatic [0]
U8
-
Service settings: Resolver - position detection dynamics
100 %
U16
1
-
Service settings: Resolver - 8 kHz safety signal
Automatisch durch Gerätetyp [0]
U8
-
Service settings: OEM service Data - SN
- (Read only)
U32
1
-
Service settings: Use measured voltage
On [1]
U8
-
Service settings: Motor identification settings
- (Read only)
U32
1
-
Service settings: Overwrite bit 4 of CiA control word
No overwrite [0]
U8
-
0x2DE0:026
Service settings: Actual speed filter time
10.0 ms
U16
10
-
Axis settings: Function of X109
HIPERFACE DSL® (OCT) [10]
U8
-
Error code
- (Read only)
U16
H
●
CiA control word
0x0000
U16
H
●
CiA status word
- (Read only)
U16
H
●
Set speed
0 rpm
I16
1
-
●
Internal set speed
x rpm (Read only)
I16
1
-
●
Actual speed
x rpm (Read only)
I16
1
-
●
Speed limits: Min. speed
0 rpm
U32
1
-
●
Speed limits: Max. speed
2147483647 rpm
U32
1
-
●
Acceleration ramp: CiA acceleration: Delta speed
0 rpm
U32
1
-
●
Acceleration ramp: CiA acceleration: Delta time
10 s
U16
1
-
●
Deceleration ramp: CiA deceleration: Delta speed
0 rpm
U32
1
-
●
Deceleration ramp: CiA deceleration: Delta time
10 s
U16
1
-
●
vl set-point factor: vl set-point factor numerator
1
I16
1
-
●
vl set-point factor: vl set-point factor denominator
1
I16
1
-
●
vl dimension factor: vl dimension factor numerator
1
I32
1
-
●
vl dimension factor: vl dimension factor denominator
1
I32
1
-
●
CiA: Quick stop mode
Ramp > switch on disabled [2]
I16
-
Shutdown option code
Disable drive function [0]
I16
-
CiA: Response to minor faults
Advanced quick stop [-2]
I16
-
CiA: Operation mode
No selection [0]
I8
-
●
CiA: Active operation mode
- (Read only)
I8
-
●
Internal set position
- (Read only)
I32
1
-
Internal actual position
- (Read only)
I32
1
-
●
Actual position
- (Read only)
I32
1
-
●
Following error window
1000
U32
1
-
●
Following error delay
0 ms
U16
1
-
●
Position reached window
1000
U32
1
-
Position reached delay
0 ms
U16
1
-
Actual speed
rpm (Read only)
I32
480000/2147483647
-
●
Set torque
0.0 %
I16
10
-
●
Max. torque
250.0 %
U16
10
-
●
Max. current
150.0 %
U16
10
-
Internal set torque
x.x % (Read only)
I16
10
-
Rated motor current
1.300 A
U32
1000
C
Rated motor torque
0.600 Nm
U32
1000
C
Actual torque
x.x % (Read only)
I16
10
-
●
Actual current
x.x % (Read only)
I16
10
-
●
DC-bus voltage
x.xxx V (Read only)
U32
1000
-
●
Set position
0
I32
1
-
●
Polarity
0
U8
1
C
Max. motor speed
6075 rpm
U32
1
-
●
Quick stop deceleration
2147483647
U32
1
-
Position encoder resolution: Encoder increments
16 bit [65536]
U32
C
Position encoder resolution: Motor revolutions
1
U32
1
C
Velocity encoder resolution: Encoder increments/s
33554432
U32
1
C
Velocity encoder resolution: Motor revolutions/s
125
U32
1
C
Offset speed
0.00 rpm
I32
480000/2147483647
-
●
Offset torque
0.0 %
I16
10
-
●
Touch probe settings
0x0000
U16
H
●
Touch probe status
- (Read only)
U16
H
●
Touch probe 1: Position at pos. edge
- (Read only)
I32
1
-
●
Touch probe 1: Position at neg. edge
- (Read only)
I32
1
-
●
Touch probe 2: Position at pos. edge
- (Read only)
I32
1
-
●
Touch probe 2: Position at neg. edge
- (Read only)
I32
1
-
●
Interpolation mode
Quadratic [-1]
I16
-
●
Interpolation time: Interpolation time mantissa
1
U8
1
-
Interpolation time: Interpolation time exponent
-3
I8
1
-
Positive torque limit
100.0 %
U16
10
-
●
Negative torque limit
100.0 %
U16
10
-
●
Following error actual value
- (Read only)
I32
1
-
●
Control effort
rpm (Read only)
I32
480000/2147483647
-
●
Position demand internal value
- (Read only)
I32
1
-
Digital input status
- (Read only)
U32
H
●
Set speed
0.00 rpm
I32
480000/2147483647
-
●
Motor manufacturer
"Lenze"
STRING[50]
-
Supported drive modes
- (Read only)
U32
H
Device profile number
- (Read only)
U32
1
-
FSoE Slave Frame Elements: Command
- (Read only)
U8
1
-
●
FSoE Slave Frame Elements: Connection ID
- (Read only)
U16
1
-
●
FSoE Slave Frame Elements: CRC_0
- (Read only)
U16
1
-
●
FSoE Slave Frame Elements: CRC_1
- (Read only)
U16
1
-
●
FSoE Slave Frame Elements: CRC_2
- (Read only)
U16
1
-
●
FSoE Slave Frame Elements: CRC_3
- (Read only)
U16
1
-
●
FSoE Slave Frame Elements: CRC_4
- (Read only)
U16
1
-
●
FSoE Slave Frame Elements: CRC_5
- (Read only)
U16
1
-
●
FSoE Slave Frame Elements: CRC_6
- (Read only)
U16
1
-
●
FSoE Master Frame Elements: Command
- (Read only)
U8
1
-
●
FSoE Master Frame Elements: Connection ID
- (Read only)
U16
1
-
●
FSoE Master Frame Elements: CRC_0
- (Read only)
U16
1
-
●
FSoE Master Frame Elements: CRC_1
- (Read only)
U16
1
-
●
FSoE Connection Communication Parameter: Version
- (Read only)
STRING[2]
-
FSoE Connection Communication Parameter: Safety address
- (Read only)
U16
1
-
FSoE Connection Communication Parameter: Connection ID
- (Read only)
U16
1
-
FSoE Connection Communication Parameter: Watchdog Time
- (Read only)
U16
1
-
FSoE Connection Communication Parameter: Connection Type
- (Read only)
U16
-
FSoE Connection Communication Parameter: Communication Parameter Length
- (Read only)
U16
1
-
FSoE Connection Communication Parameter: Application Parameter Length
- (Read only)
U16
1
-
FSoE Connection Diagnosis: Connection State
- (Read only)
U16
-
Safety addresses: FSoE address
- (Read only)
U16
1
-
Safety addresses: Safety address
1
U16
1
-