Parameter attribute list

The parameter attribute list in particular contains some information required for reading and writing parameters via network.
 
Note the special features for writing the safe parameters of the Extended Safety:
»EASY Starter« or »PLC-Designer«: Writing the safe parameters is only possible via the "+Safe parameter list+" tab. The safe parameters can only be read via the "Parameter list" tab.
Higher-level controller: Writing of the safe parameters is possible by the parameter set transfer.
 
 
The following conventions are used in this documentation for specifying the parameter address:
• The index is specified as a hexadecimal value.
• The subindex is specified as a decimal value.
 
 
–
The parameter attribute list contains all parameters of the inverter.
 
–
The parameter attribute list is sorted by addresses (index:subindex) in ascending order.
 
How to read the parameter attribute list:
Column
Meaning
Address
Address of the parameter in the object directory. Format: Index:Subindex
Name
Parameter name
Default setting
Default setting of the parameter
Data type
Data type of the parameter:
I8
INTEGER_8
1 byte, with sign
I16
INTEGER_16
2 bytes with sign
I32
INTEGER_32
4 bytes with sign
I64
INTEGER_64
8 bytes with sign
U8
UNSIGNED_8
1 byte without sign
U16
UNSIGNED_16
2 bytes without sign
U32
UNSIGNED_32
4 bytes without sign
U64
UNSIGNED_64
8 bytes without sign
STRING[xx]
VISIBLE_STRING
ASCII string (with character length xx)
OCTET[xx]
OCTET_STRING
OCTET string (with xx bytes)
IDX
4 bytes without sign. Is used specially for addressing parameters.
Factor
Factor for data transmission via network,
depending on the number of decimal positions:
1
no decimal positions
10
1 decimal position
100
2 decimal positions
1000
3 decimal positions
10000
4 decimal positions
A
Attributes (combinations of several attributes also possible):
C
Setting can only be changed if the inverter is disabled.
E
Value is displayed as IP address.
H
Value is displayed in hexadecimal form.
T
Value is displayed as time.
M
Mapping:
●
Mapping permitted.
Mapping not permissible.
 
Parameter attribute list (short overview of all parameter indexes)
Address
Name
Default setting
Data type
Factor
A
M
Device type
- (Read only)
U32
1
-
Error register
- (Read only)
U8
1
-
●
Manufacturer device name
- (Read only)
STRING[50]
-
Manufacturer hardware version
- (Read only)
STRING[50]
-
Manufacturer software version
- (Read only)
STRING[50]
-
Identity object: Vendor ID
- (Read only)
U32
1
-
Identity object: Product Code
- (Read only)
U32
-
Identity object: Revision number
- (Read only)
U32
1
-
Identity object: Serial number
- (Read only)
U32
1
-
Error settings: Local error reaction
Device specific state [2]
U32
-
Error settings: Sync error counter limit
20
U16
1
-
Device data: Product code
- (Read only)
STRING[50]
-
Device data: Serial number
- (Read only)
STRING[50]
-
Device data: Production date
- (Read only)
STRING[50]
-
Device data: CU firmware version
- (Read only)
STRING[50]
-
Device data: CU bootloader version
- (Read only)
STRING[50]
-
Device data: Object directory version
- (Read only)
U32
1
-
Device data: Communication firmware revision number
- (Read only)
STRING[50]
-
Device data: Safety module version
- (Read only)
STRING[50]
-
Device name
"Device"
STRING[128]
-
Device module: Safety module
- (Read only)
STRING[50]
-
Device module: CU serial number
- (Read only)
STRING[50]
-
Device module: PU serial number
- (Read only)
STRING[50]
-
Device module: Type communication module
- (Read only)
STRING[50]
-
Device module: Serial number communication module
- (Read only)
STRING[50]
-
Device module: Hardware version communication module
- (Read only)
STRING[50]
-
Device module: Type encoder 1
- (Read only)
STRING[50]
-
Device module: Serial number encoder 1
- (Read only)
STRING[50]
-
Device module: Hardware version encoder 1
- (Read only)
STRING[50]
-
Device module: Type encoder 2
- (Read only)
STRING[50]
-
Device module: Serial number encoder 2
- (Read only)
STRING[50]
-
Device module: Hardware version encoder 2
- (Read only)
STRING[50]
-
Device event monitor: EreignisortEvent location
- (Read only)
U8
-
Device event monitor: Severity
- (Read only)
U8
-
Device event monitor: Event status
- (Read only)
U8
-
Device event monitor: Number of current event
- (Read only)
U32
H
Device event monitor: Time stamp of current event
x ns (Read only)
U64
1
T
Device information: SD card status
- (Read only)
U8
-
Device information: Application Credit available
- (Read only)
U16
1
-
Device information: License information
- (Read only)
U16
-
Application information: Active application
- (Read only)
U16
-
Application information: Application Credit required
- (Read only)
U16
1
-
Application information: Application cycle time
- (Read only)
U16
1
-
EoE information: Virtual MAC address
- (Read only)
STRING[32]
-
EoE information: IP address
- (Read only)
STRING[32]
-
EoE information: Subnet mask
- (Read only)
STRING[32]
-
EoE information: Standard gateway
- (Read only)
STRING[32]
-
EoE information: DNS server
- (Read only)
STRING[32]
-
EoE information: DNS name
- (Read only)
STRING[50]
-
EoE information: Received packages
 
U32
1
-
EoE information: Transmitted packages
 
U32
1
-
Optical tracking: Start detection
Stop [0]
U8
-
Optical tracking: Blinking duration
5 s
U16
1
-
Device commands: Load default settings
Off / ready [0]
U8
C
Device commands: Save user data
Off / ready [0]
U8
-
Device commands: Delete logbook
Off / ready [0]
U8
-
Device commands: Restart Device
Off / ready [0]
U8
-
Device commands: Export Logbook
Off / ready [0]
U8
-
Device commands: Delete Logfiles
Off / ready [0]
U8
-
Device commands: Activate loaded application
Off / ready [0]
U8
-
Device commands: Load TA default settings
Off / ready [0]
U8
C
Device commands: Parameter-Backup
Off / ready [0]
U8
C
Device commands: Restart extended safety
Off / ready [0]
U8
-
Device commands: Upload application
Off / ready [0]
U8
-
Device commands: Restore
Off / ready [0]
U8
C
Device commands: Start application
Off / ready [0]
U8
C
Device commands: Stop application
Off / ready [0]
U8
C
CRC parameter set
- (Read only)
U32
1
-
PIN1 access protection
0
I16
1
-
PIN2 access protection
0
I16
1
-
PIN1/PIN2 log-in
0
I16
1
-
Access protection status
- (Read only)
U16
H
Brand protection: PIN set
0
I32
1
-
Brand protection: PIN input
0
I32
1
-
Brand protection: Encryption
0
U8
1
-
Delete home position
Ready [0]
U8
-
Activate muting
Ready [0]
U8
-
Parameter set: Version
i950 ES V1.3 [10303]
U16
-
Parameter set: Project CRC
0
U32
1
-
Parameter set: Status
- (Read only)
U8
-
Parameter set: Current CRC
- (Read only)
U32
1
-
Parameter set: Last valid CRC
- (Read only)
U32
1
-
Parameter set: Parameter setting time stamp
x s (Read only)
U32
1
-
Parameter set: Error information 1
- (Read only)
U32
1
-
Parameter set: Error information 2
- (Read only)
U32
1
-
Parameter set: Error information 3
- (Read only)
U32
1
-
Parameter set: Current CRC without specific identifiers
- (Read only)
U32
1
-
SD-In: SD-In1 sensor type
Active sensor [2]
U8
-
SD-In: SD-In2 sensor type
Input disabled [0]
U8
-
SD-In: SD-In3 sensor type
Input disabled [0]
U8
-
SD-In: SD-In4 sensor type
Input disabled [0]
U8
-
SD-In: SD-In1 discrepancy time
1000 ms
U16
1
-
SD-In: SD-In2 discrepancy time
10 ms
U16
1
-
SD-In: SD-In3 discrepancy time
10 ms
U16
1
-
SD-In: SD-In4 discrepancy time
10 ms
U16
1
-
SD-In: SD-In1 input delay
0 ms
U16
1
-
SD-In: SD-In2 input delay
0 ms
U16
1
-
SD-In: SD-In3 input delay
0 ms
U16
1
-
SD-In: SD-In4 input delay
0 ms
U16
1
-
Input image
- (Read only)
U32
H
Status bits inputs: SD-In1
- (Read only)
BOOLEAN
1
-
●
Status bits inputs: SD-In2
- (Read only)
BOOLEAN
1
-
●
Status bits inputs: SD-In3
- (Read only)
BOOLEAN
1
-
●
Status bits inputs: SD-In4
- (Read only)
BOOLEAN
1
-
●
Status bits inputs: AIS Dig-In
- (Read only)
BOOLEAN
1
-
Status bits inputs: AIE Dig-In
- (Read only)
BOOLEAN
1
-
Status bits inputs: IRS Dig-In
- (Read only)
BOOLEAN
1
-
Status bits inputs: IRL Dig-In
- (Read only)
BOOLEAN
1
-
SD-Out: SD-Out1 source S-Bus
Disabled [0]
U8
-
SD-Out: SD-Out1 logic function
OR [0]
U8
-
Output image
- (Read only)
U16
H
Status bits outputs: SD-Out1
- (Read only)
BOOLEAN
1
-
●
CAS Source SD-In
Disabled [0]
U8
-
CAS: Stop delay
x ms (Read only)
U16
1
-
S-Bus configuration
No safety bus [0]
U8
-
S-Bus control bits: SD-Out1
- (Read only)
BOOLEAN
1
-
●
S-Bus: FSoE project CRC
 
U32
1
-
S-Bus: PROFIsafe status
- (Read only)
U8
-
S-Bus: PROFIsafe status byte
- (Read only)
U8
H
S-Bus: PROFIsafe control byte
- (Read only)
U8
H
Safety software: Firmware version
- (Read only)
STRING[50]
-
Safety hardware: Hardware version
- (Read only)
STRING[50]
-
Safety hardware: Product code
- (Read only)
STRING[50]
-
Safety hardware: Serial number
- (Read only)
STRING[50]
-
Safety hardware: Production date
- (Read only)
STRING[50]
-
Safety event history: Current severity
- (Read only)
U8
-
Safety event history: Internal event 1
- (Read only)
U16
H
Safety event history: Internal event 2
- (Read only)
U16
H
Safety event history: Internal event 3
- (Read only)
U16
H
Safety event history: Internal event 4
- (Read only)
U16
H
Safety event history: Internal event 5
- (Read only)
U16
H
Safety event history: Internal event 6
- (Read only)
U16
H
Safety event history: Internal event 7
- (Read only)
U16
H
Safety event history: Internal event 8
- (Read only)
U16
H
Safety event history: Internal event 9
- (Read only)
U16
H
Safety event history: Internal event 10
- (Read only)
U16
H
Safety event history: Internal event 11
- (Read only)
U16
H
Safety event history: Internal event 12
- (Read only)
U16
H
Safety event history: Internal event 13
- (Read only)
U16
H
Safety event history: Internal event 14
- (Read only)
U16
H
Safety event history: Internal event 15
- (Read only)
U16
H
Safety event history: Internal event 16
- (Read only)
U16
H
Safety hardware: Power-on time
x s (Read only)
U32
1
-
Safety status
- (Read only)
U16
1
-
MUT: Mute S-Bus
No muting [0]
U8
-
MUT: Mute SD-In1
No muting [0]
U8
-
MUT: Mute SD-In2
No muting [0]
U8
-
MUT: Mute SD-In3
No muting [0]
U8
-
MUT: Mute SD-In4
No muting [0]
U8
-
MUT: Password
0
U32
1
-
MUT: Remaining time
x s (Read only)
U32
1
-
MUT "MUT active" - Output
Disabled [0]
U8
-
CANopen communication
No action/no error [0]
U8
-
CANopen settings: Node ID
1
U8
1
-
CANopen settings: Baud rate
500 kbps [5]
U8
-
CANopen settings: Slave/Master
Slave [0]
U8
-
CANopen settings: Start remote delay
3000
U16
1
-
CANopen settings: Activate SDO2 channel
Not active [0]
U8
-
CANopen settings: COB-ID Configuration - PDO
Base + node-ID [0]
U8
-
CANopen settings: COB-ID Configuration - SDO2
Freely configurable [1]
U8
-
CANopen settings: Sync - Cycle time
0
U32
1
-
CANopen settings: Sync - Phase position
0
U32
1
-
CANopen settings: Sync - Tolerance
100
U32
1
-
CANopen settings: Sync - PLL increment
39 ns [3]
U8
-
Active CANopen settings: Active node ID
- (Read only)
U8
1
-
Active CANopen settings: Active baud rate
- (Read only)
U8
-
Active CANopen settings: COB-ID Emergency telegram (EMCY)
- (Read only)
U32
H
CANopen settings: SYNC - COB-ID
0x00000080
U32
H
CANopen settings: Communication cyclic period
0
U32
1
-
CANopen settings: EMCY - Inhibit time
0.0 ms
U16
10
-
CANopen settings: Consumer heartbeat time 1
0x00000000
U32
H
CANopen settings: Consumer heartbeat time 2
0x00000000
U32
H
CANopen settings: Consumer heartbeat time 3
0x00000000
U32
H
CANopen settings: Consumer heartbeat time 4
0x00000000
U32
H
CANopen settings: Producer heartbeat time
0 ms
U16
1
-
CANopen settings: Communication error
Status -> Pre-operational [0]
U8
-
CANopen settings: COB-ID client -> server (rx)
0x80000641
U32
H
CANopen settings: COB-ID server -> client (tx)
0x800005C1
U32
H
CANopen settings: SDO client - Node-ID
1
U8
1
-
CANopen settings: RPDO1 - COB-ID
0x00000201
U32
H
CANopen settings: RPDO1 - Transmission type
255
U8
1
-
CANopen settings: RPDO1 - Event timer
100 ms
U16
1
-
CANopen settings: RPDO2 - COB-ID
0x80000301
U32
H
CANopen settings: RPDO2 - Transmission type
255
U8
1
-
CANopen settings: RPDO2 - Event timer
100 ms
U16
1
-
CANopen settings: RPDO3 - COB-ID
0x80000401
U32
H
CANopen settings: RPDO3 - Transmission type
255
U8
1
-
CANopen settings: RPDO3 - Event timer
100 ms
U16
1
-
CANopen settings: RPDO4 - COB-ID
0x80000501
U32
H
CANopen settings: RPDO4 - Transmission type
255
U8
1
-
CANopen settings: RPDO4 - Event timer
100 ms
U16
1
-
CANopen settings: TPDO1 - COB-ID
0x40000181
U32
H
CANopen settings: TPDO1 - Transmission type
255
U8
1
-
CANopen settings: TPDO1 - Inhibit time
0.0 ms
U16
10
-
CANopen settings: TPDO1 - Event timer
20 ms
U16
1
-
CANopen settings: TPDO2 - COB-ID
0xC0000281
U32
H
CANopen settings: TPDO2 - Transmission type
255
U8
1
-
CANopen settings: TPDO2 - Inhibit time
0.0 ms
U16
10
-
CANopen settings: TPDO2 - Event timer
0 ms
U16
1
-
CANopen settings: TPDO3 - COB-ID
0xC0000381
U32
H
CANopen settings: TPDO3 - Transmission type
255
U8
1
-
CANopen settings: TPDO3 - Inhibit time
0.0 ms
U16
10
-
CANopen settings: TPDO3 - Event timer
0 ms
U16
1
-
CANopen settings: TPDO4 - COB-ID
0xC0000481
U32
H
CANopen settings: TPDO4 - Transmission type
255
U8
1
-
CANopen settings: TPDO4 - Inhibit time
0.0 ms
U16
10
-
CANopen settings: TPDO4 - Event timer
0 ms
U16
1
-
CANopen time-out status
- (Read only)
U32
H
CANopen status
- (Read only)
U16
-
CANopen controller status
- (Read only)
U16
-
CANopen statistics: PDO1 received
- (Read only)
U16
1
-
CANopen statistics: PDO2 received
- (Read only)
U16
1
-
CANopen statistics: PDO3 received
- (Read only)
U16
1
-
CANopen statistics: POD3 recieved
- (Read only)
U16
1
-
CANopen statistics: PDO1 transmitted
- (Read only)
U16
1
-
CANopen statistics: PDO2 transmitted
- (Read only)
U16
1
-
CANopen statistics: PDO3 transmitted
- (Read only)
U16
1
-
CANopen statistics: PDO4 transmitted
- (Read only)
U16
1
-
CANopen statistics: SDO1 telegrams
- (Read only)
U16
1
-
CANopen statistics: SDO2 telegrams
- (Read only)
U16
1
-
CANopen statistics: Sync - Deviation
- (Read only)
I32
1000
-
CANopen statistics: Sync - Phase position distance
- (Read only)
I32
1000
-
CANopen error counter
- (Read only)
U16
1
-
Communication module ID: Active module ID
- (Read only)
U8
-
Communication module ID: Module ID connected
- (Read only)
U8
-
EtherCAT communication
No action/no error [0]
U8
-
Active EtherCAT settings: Tx length
- (Read only)
U16
1
-
Active EtherCAT settings: Rx length
- (Read only)
U16
1
-
EtherCAT status
- (Read only)
U16
-
●
EtherCAT error
- (Read only)
U16
H
onboard EtherCAT: Interface mode
Slave [0]
U8
C
onboard EtherCAT - Information: Active interface mode
- (Read only)
U8
-
onboard EtherCAT - status
- (Read only)
U16
-
●
onboard EtherCAT - Error
- (Read only)
U16
1
-
PROFINET communication
No action/no error [0]
U8
-
PROFINET settings: IP address
0.0.0.0
U32
E
PROFINET settings: Subnet
0.0.0.0
U32
E
PROFINET settings: Gateway
0.0.0.0
U32
E
PROFINET settings: Station name
STRING[240]
-
PROFINET settings: I&M1 System designation
STRING[32]
-
PROFINET settings: I&M1 Installation site
STRING[22]
-
PROFINET settings: I&M2 Installation date
STRING[16]
-
PROFINET settings: I&M3 additional information
STRING[54]
-
PROFINET settings: I&M4 signature code
"000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000"
OCTET[54]
-
Active PROFINET settings: IP address
- (Read only)
U32
E
Active PROFINET settings: Subnet
- (Read only)
U32
E
Active PROFINET settings: Gateway
- (Read only)
U32
E
Active PROFINET settings: Station name
- (Read only)
STRING[240]
-
Active PROFINET settings: MAC Address
- (Read only)
OCTET[6]
-
PROFINET status
- (Read only)
U16
H
PROFINET error: Error 1
- (Read only)
U16
-
PROFINET error: Error 2
- (Read only)
U16
H
EtherNet/IP communication
No action/no error [0]
U8
-
EtherNet/IP settings: IP address
192.168.124.16
U32
E
EtherNet/IP settings: Subnet
255.255.255.0
U32
E
EtherNet/IP settings: Gateway
0.0.0.0
U32
E
EtherNet/IP settings: Host name
STRING[64]
-
EtherNet/IP settings: IP configuration
DHCP [2]
U8
-
EtherNet/IP settings: Multicast TTL
1
U8
1
-
EtherNet/IP settings: Multicast allocation
Default allocation [0]
U8
-
EtherNet/IP settings: Multicast IP address
239.64.2.224
U32
E
EtherNet/IP settings: Multicast number
1
U8
1
-
EtherNet/IP settings: Timeout
10000
U16
1
-
Active EtherNet/IP settings: IP address
- (Read only)
U32
E
Active EtherNet/IP settings: Subnet
- (Read only)
U32
E
Active EtherNet/IP settings: Gateway
- (Read only)
U32
E
Active EtherNet/IP settings: MAC address
- (Read only)
OCTET[6]
-
Active EtherNet/IP settings: Multicast address
- (Read only)
U32
E
Port 1
Auto-Negotiation [0]
U16
-
Port 2
Auto-Negotiation [0]
U16
-
Active port settings: Port 1 (X266)
- (Read only)
U16
-
Active port settings: Port 2 (X267)
- (Read only)
U16
-
Address conflict detection
Enabled [1]
U8
-
CIP module status
- (Read only)
U16
-
EtherNet/IP status
- (Read only)
U16
-
Device: Ethernet commands: Device: Start firmware update
Off / ready [0]
U8
C
Engineering port control
No action/No error [0]
U8
-
Engineering port settings: IP address
0.0.0.0
U32
E
Engineering port settings: Subnet
0.0.0.0
U32
E
Engineering port settings: Gateway
0.0.0.0
U32
E
Engineering port settings: DHCP
Enabled [1]
U8
-
Engineering port settings: DNS server address
0.0.0.0
U32
E
Active engineering port settings: IP address
- (Read only)
U32
E
Active engineering port settings: Subnet
- (Read only)
U32
E
Active engineering port settings: Gateway
- (Read only)
U32
E
Active engineering port settings: DHCP
- (Read only)
U8
-
Active engineering port settings: MAC address
- (Read only)
OCTET[6]
-
Active engineering port settings: Link status
- (Read only)
U8
-
Active engineering port settings: DNS server address
- (Read only)
U32
E
NTP server addresses: Activate NTP server addresses
No action/no error [0]
U8
-
NTP server addresses: NTP server address 1
0.0.0.0
U32
E
NTP server addresses: NTP server address 2
0.0.0.0
U32
E
NTP server addresses: NTP server address 3
0.0.0.0
U32
E
NTP server addresses: NTP server address 4
0.0.0.0
U32
E
NTP server addresses: NTP server name 1
STRING[253]
-
NTP server addresses: NTP server name 2
STRING[253]
-
NTP server addresses: NTP server name 3
STRING[253]
-
NTP server addresses: NTP server name 4
STRING[253]
-
System time: Setting method
NTP server [0]
U8
-
System time: Current time
 ns
U64
1
T
Network input data: Input data 1
 
U32
1
-
Network input data: Input data 2
 
U32
1
-
Network input data: Input data 3
 
U32
1
-
Network input data: Input data 4
 
U32
1
-
Network input data: Input data 5
 
U32
1
-
Network input data: Input data 6
 
U32
1
-
Network input data: Input data 7
 
U32
1
-
Network input data: Input data 8
 
U32
1
-
Network input data: Input data 9
 
U32
1
-
Network input data: Input data 10
 
U32
1
-
Network input data: Input data 11
 
U32
1
-
Network input data: Input data 12
 
U32
1
-
Network input data: Input data 13
 
U32
1
-
Network input data: Input data 14
 
U32
1
-
Network input data: Input data 15
 
U32
1
-
Network input data: Input data 16
 
U32
1
-
Network output data: Output data 1
- (Read only)
U32
1
-
Network output data: Output data 2
- (Read only)
U32
1
-
Network output data: Output data 3
- (Read only)
U32
1
-
Network output data: Output data 4
- (Read only)
U32
1
-
Network output data: Output data 5
- (Read only)
U32
1
-
Network output data: Output data 6
- (Read only)
U32
1
-
Network output data: Output data 7
- (Read only)
U32
1
-
Network output data: Output data 8
- (Read only)
U32
1
-
Network output data: Output data 9
- (Read only)
U32
1
-
Network output data: Output data 10
- (Read only)
U32
1
-
Network output data: Output data 11
- (Read only)
U32
1
-
Network output data: Output data 12
- (Read only)
U32
1
-
Network output data: Output data 13
- (Read only)
U32
1
-
Network output data: Output data 14
- (Read only)
U32
1
-
Network output data: Output data 15
- (Read only)
U32
1
-
Network output data: Output data 16
- (Read only)
U32
1
-
Touch probe filter time
0
U16
1
-
Hardware-Diagnose: External supply voltage
x.x V (Read only)
U16
10
-
Hardware-Diagnose: Control board temperature
x.x °C (Read only)
I16
10
-
Mains settings: Rated mains voltage
400 Veff [1]
U8
-
Mains settings: Undervoltage warning threshold
430 V
U16
1
-
Mains settings: Undervoltage error threshold
x V (Read only)
U16
1
-
Mains settings: Undervoltage reset threshold
x V (Read only)
U16
1
-
Mains settings: Overvoltage warning threshold
795 V
U16
1
-
Mains settings: Overvoltage error threshold
x V (Read only)
U16
1
-
Mains settings: Overvoltage reset threshold
x V (Read only)
U16
1
-
Mains settings: DC link voltage critical
- (Read only)
U8
1
-
●
Brake energy management: Reduced threshold
0 V
U16
1
-
Brake resistor: Minimum resistance
x.x Ω (Read only)
U16
10
-
Brake resistor: Resistance value
180.0 Ω
U16
10
-
Brake resistor: Rated power
5600 W
U32
1
-
Brake resistor: Maximum thermal load
485 kWs
U32
1
-
Brake resistor: Reference resistance
Minimum resistance [0]
U8
-
Brake resistor: Thermal load
x.x % (Read only)
U16
10
-
Brake resistor: Warning threshold
90.0 %
U16
10
-
Brake resistor: Response to warning
Warning [2]
U8
-
Brake resistor: Response to error
No response [0]
U8
-
Distributed Clocks: Real time status
- (Read only)
U8
-
Distributed Clocks: First setting time
x ns (Read only)
U64
1
T
Distributed Clocks: Newest setting time
x ns (Read only)
U64
1
T
Distributed Clocks: Current time
x ns (Read only)
U64
1
T
0x2581:001
Application synchronization: Sync - Source
onboard EtherCAT [1]
U8
-
0x2581:002
Application synchronization: Sync - Status
- (Read only)
U8
-
0x2581:005
Application synchronization: Sync - Active cycle time
- (Read only)
U32
1
-
Energy saving: State of actual energy saving mode
- (Read only)
U8
H
Favorites settings: Parameter 1
 
U32
1
-
Favorites settings: Parameter 2
 
U32
1
-
Favorites settings: Parameter 3
 
U32
1
-
Favorites settings: Parameter 4
 
U32
1
-
Favorites settings: Parameter 5
 
U32
1
-
Favorites settings: Parameter 6
 
U32
1
-
Favorites settings: Parameter 7
 
U32
1
-
Favorites settings: Parameter 8
 
U32
1
-
Favorites settings: Parameter 9
 
U32
1
-
Favorites settings: Parameter 10
 
U32
1
-
Favorites settings: Parameter 11
 
U32
1
-
Favorites settings: Parameter 12
 
U32
1
-
Favorites settings: Parameter 13
 
U32
1
-
Favorites settings: Parameter 14
 
U32
1
-
Favorites settings: Parameter 15
 
U32
1
-
Favorites settings: Parameter 16
 
U32
1
-
Favorites settings: Parameter 17
 
U32
1
-
Favorites settings: Parameter 18
 
U32
1
-
Favorites settings: Parameter 19
 
U32
1
-
Favorites settings: Parameter 20
 
U32
1
-
Favorites settings: Parameter 21
 
U32
1
-
Favorites settings: Parameter 22
 
U32
1
-
Favorites settings: Parameter 23
 
U32
1
-
Favorites settings: Parameter 24
 
U32
1
-
Favorites settings: Parameter 25
 
U32
1
-
Favorites settings: Parameter 26
 
U32
1
-
Favorites settings: Parameter 27
 
U32
1
-
Favorites settings: Parameter 28
 
U32
1
-
Favorites settings: Parameter 29
 
U32
1
-
Favorites settings: Parameter 30
 
U32
1
-
Favorites settings: Parameter 31
 
U32
1
-
Favorites settings: Parameter 32
 
U32
1
-
Favorites settings: Parameter 33
 
U32
1
-
Favorites settings: Parameter 34
 
U32
1
-
Favorites settings: Parameter 35
 
U32
1
-
Favorites settings: Parameter 36
 
U32
1
-
Favorites settings: Parameter 37
 
U32
1
-
Favorites settings: Parameter 38
 
U32
1
-
Favorites settings: Parameter 39
 
U32
1
-
Favorites settings: Parameter 40
 
U32
1
-
Favorites settings: Parameter 41
 
U32
1
-
Favorites settings: Parameter 42
 
U32
1
-
Favorites settings: Parameter 43
 
U32
1
-
Favorites settings: Parameter 44
 
U32
1
-
Favorites settings: Parameter 45
 
U32
1
-
Favorites settings: Parameter 46
 
U32
1
-
Favorites settings: Parameter 47
 
U32
1
-
Favorites settings: Parameter 48
 
U32
1
-
Favorites settings: Parameter 49
 
U32
1
-
Favorites settings: Parameter 50
 
U32
1
-
0x2630:003
Settings for digital inputs: X4 - DI5-DI8 configuration
DI5, DI6, DI7, DI8 [0]
U8
C
Inversion of digital inputs: Digital input 1
Not inverted [0]
U8
-
Inversion of digital inputs: Digital input 2
Not inverted [0]
U8
-
Inversion of digital inputs: Digital input 3
Not inverted [0]
U8
-
Inversion of digital inputs: Digital input 4
Not inverted [0]
U8
-
Inversion of digital inputs: Digital input 5
Not inverted [0]
U8
-
Inversion of digital inputs: Digital input 6
Not inverted [0]
U8
-
Inversion of digital inputs: Digital input 7
Not inverted [0]
U8
-
Inversion of digital inputs: Digital input 8
Not inverted [0]
U8
-
Inversion of digital inputs: Digital input 9
Not inverted [0]
U8
-
Digital input debounce time: Digital input 1
0 ms
U8
1
-
Digital input debounce time: Digital input 2
0 ms
U8
1
-
Digital input debounce time: Digital input 3
0 ms
U8
1
-
Digital input debounce time: Digital input 4
0 ms
U8
1
-
Digital input debounce time: Digital input 5
0 ms
U8
1
-
Digital input debounce time: Digital input 6
0 ms
U8
1
-
Digital input debounce time: Digital input 7
0 ms
U8
1
-
Digital input debounce time: Digital input 8
0 ms
U8
1
-
Digital input debounce time: Digital input 9
0 ms
U8
1
-
Digital outputs function: Digital output 1
Signal from application [10]
U8
-
Inversion of digital outputs: Digital output 1
Not inverted [0]
U8
-
Inversion of digital outputs: Digital output 2
Not inverted [0]
U8
-
Inversion of digital outputs: Digital output 3
Not inverted [0]
U8
-
Inversion of digital outputs: Digital output 4
Not inverted [0]
U8
-
Inversion of digital outputs: Digital output 5
Not inverted [0]
U8
-
Inversion of digital outputs: Digital output 6
Not inverted [0]
U8
-
Analog input 1: Input range
0 ... 10 VDC [0]
U8
-
Analog input 1: Filter time
10 ms
U16
1
-
Analog input 1: Dead band
0.0 %
U16
10
-
Analog input 1: Error response
No response [0]
U8
-
Analog input 1: Minimum value for scaling
0.0 %
I16
10
-
Analog input 1: Maximum value for scaling
100.0 %
I16
10
-
Analog input 2: Input range
0 ... 10 VDC [0]
U8
-
Analog input 2: Filter time
10 ms
U16
1
-
Analog input 2: Dead band
0.0 %
U16
10
-
Analog input 2: Error response
No response [0]
U8
-
Analog input 2: Minimum value for scaling
0.0 %
I16
10
-
Analog input 2: Maximum value for scaling
100.0 %
I16
10
-
Analog output 1: Output range
Inhibited [0]
U8
-
Analog output 1: Min. signal
0.0
I16
10
-
Analog output 1: Max. signal
100.0
I16
10
-
Analog output 1: Scaled percent value
0.00 %
I16
100
-
●
Digital inputs internal control: Activation
Off [0]
U8
-
Digital inputs internal control: DI1 internal control
Off [0]
U8
-
Digital inputs internal control: DI2 internal control
Off [0]
U8
-
Digital inputs internal control: DI3 internal control
Off [0]
U8
-
Digital inputs internal control: DI4 internal control
Off [0]
U8
-
Digital inputs internal control: DI5 internal control
Off [0]
U8
-
Digital inputs internal control: DI6 internal control
Off [0]
U8
-
Digital inputs internal control: DI7 internal control
Off [0]
U8
-
Digital inputs internal control: DI8 internal control
Off [0]
U8
-
Digital inputs internal control: DI9 internal control
Off [0]
U8
-
Digital outputs internal control: Activation
Off [0]
U8
-
Digital outputs internal control: DO1 internal control
Off [0]
U8
-
Digital outputs internal control: DO2 internal control
Off [0]
U8
-
Digital outputs internal control: DO3 internal control
Off [0]
U8
-
Digital outputs internal control: DO4 internal control
Off [0]
U8
-
Digital outputs internal control: DO5 internal control
Off [0]
U8
-
Digital outputs internal control: DO6 internal control
Off [0]
U8
-
Analog inputs internal control: Activation
Off [0]
U8
-
Analog inputs internal control: AI1 internal control
100.00 %
I16
100
-
Analog inputs internal control: AI2 internal control
100.00 %
I16
100
-
Activation
Off [0]
U8
-
AO1 internal control
100.00 %
I16
100
-
Holding brake control: Brake mode
Off [2]
U8
-
●
Holding brake control: Brake closing time
100 ms
U16
1
-
Holding brake control: Brake opening time
100 ms
U16
1
-
Holding brake control: Brake detection
- (Read only)
U16
-
Holding brake control: Brake polarity
Normal [0]
U8
-
Holding brake control: Brake error response
Fault > CiA402 [1]
U8
-
Holding brake control: Starting torque source
Torque in 0x2820:010 [1]
U16
-
Holding brake control: Starting torque
0.0 %
I16
10
-
●
Holding brake control: Override of the brake control
No override active [0]
U8
-
●
Holding brake control: Holding load ramptime
0 ms
U16
1
-
Holding brake control: Brake status
- (Read only)
U8
-
Holding brake control: Brake opening time test signal
500 ms
U16
1
-
Holding brake control: Brake control word
0x00
U8
H
Holding brake control: Detected actual torque
x.x % (Read only)
I16
10
-
Holding brake control: Holding brake supply voltage
No reduction [100]
U8
-
Holding brake control: Control configuration
Via internal brake module [0]
U8
-
Axis commands: Enable inverter
Inverter enabled [1]
U8
-
0x2822:003
Axis commands: Reset error
Off/Ready [0]
U8
-
Axis commands: Load default Lh saturation characteristic
Off/Ready [0]
U8
-
Axis commands: Load default inverter characteristic
Off/Ready [0]
U8
-
Axis commands: Estimate optimum magnetizing current
Off/Ready [0]
U8
-
0x2822:024
Axis commands: Estimate basic motor parameters based on rated data
Off/Ready [0]
U8
-
Axis commands: Get motor encoder characteristic (resolver)
Off/Ready [0]
U8
-
Axis commands: Get motor encoder information (HIPERFACE®)
Off/Ready [0]
U8
-
0x2822:027
Axis commands: Calculate SLVC controller parameter
RANLI_C2822_S027_GEN_V00000000 [0]
U8
-
Axis commands: Get load encoder/master encoder characteristic (resolver)
Off/Ready [0]
U8
-
Axis commands: Get load encoder/master encoder information (HIPERFACE®)
Off/Ready [0]
U8
-
Axis commands: Estimate all motor parameters based on rated data
Off/Ready [0]
U8
-
Axis commands: HIPERFACE (A): Set position with synchronization
Off/Ready [0]
U8
-
Axis commands: HIPERFACE (A): Set position with synchronization
Off/Ready [0]
U8
-
0x2822:042
Axis commands: Calculate speed filter time constant
Off/Ready [0]
U8
-
0x2822:043
Axis commands: Load power dependent motor parameters
RANLI_C2822_S043_GEN_V00000000 [0]
U8
-
0x2822:044
Axis commands: Cogging torque compensation
RANLI_C2822_S044_GEN_V00000000 [0]
U8
-
Status of axis commands
x % (Read only)
U8
1
-
Control via PDO/Application
Keypad [1]
U8
C
Drive mode selection
CiA402 operating modes [0]
U8
C
Timeout for error response -> quickstop
4 s
U32
1
-
Status words: Cause of disable
- (Read only)
U32
H
●
Status words: Extended status word
- (Read only)
U16
H
●
I/O diagnostic: Application level of the digital inputs
- (Read only)
U32
H
●
I/O diagnostic: Digital output levels
- (Read only)
U32
H
●
Inverter control word
0x0000
U16
H
●
Inverter status word
- (Read only)
U16
H
●
Identification status
- (Read only)
U16
H
Inverter status word 2
- (Read only)
U16
H
●
Manual test mode: Current setpoint
0 %
I16
1
-
●
Manual test mode: Frequency
0.0 Hz
I16
10
-
●
Manual test mode: Starting angle
0.0 °
I16
10
-
Manual control mode: Current setpoint
30 %
U16
1
-
●
Manual control mode: Frequency
0.0 Hz
I16
10
-
●
Manual control mode: Ramp time (current)
0 ms
U16
1
-
Manual control mode: Ramp time (frequency)
500 ms
U16
1
-
Manual control mode: Time monitoring (frequency)
2500 ms
U32
1
-
Manual control mode: Current controller gain
20.00 V/A
U32
100
-
Manual control mode: Current controller reset time
20.00 ms
U32
100
-
Error reset time
x ms (Read only)
I32
1
-
Reset error
0
U8
1
-
Additional error information: Component ID
- (Read only)
U16
1
-
●
Current error
- (Read only)
OCTET[64]
-
CANopen monitoring: RPDO1-Timeout
Warning [2]
U8
-
CANopen monitoring: RPDO2-Timeout
Warning [2]
U8
-
CANopen monitoring: RPDO3-Timeout
Warning [2]
U8
-
CANopen monitoring: RPDO4-Timeout
Warning [2]
U8
-
CANopen monitoring: Heartbeat-Timeout Consumer 1
Warning [2]
U8
-
CANopen monitoring: Heartbeat-Timeout Consumer 2
Warning [2]
U8
-
CANopen monitoring: Heartbeat-Timeout Consumer 3
Warning [2]
U8
-
CANopen monitoring: Heartbeat-Timeout Consumer 4
Warning [2]
U8
-
CANopen monitoring: "Bus-off" state change
Warning [2]
U8
-
CANopen monitoring: Warning
Warning [2]
U8
-
Network monitoring: Watchdog elapsed
Warning [2]
U8
-
Network monitoring: Data exchange exited
No response [0]
U8
-
Network monitoring: Invalid configuration
Warning [2]
U8
-
Network monitoring: Initialisation error
Warning [2]
U8
-
Network monitoring: Invalid process data
Warning [2]
U8
-
Network monitoring: Time-out explicit message
Warning [2]
U8
-
Network monitoring: Timeout communication
Warning [2]
U8
-
Diagnostic configuration: Alarm suppression
0x0000
U16
H
onboard EtherCAT monitoring: Watchdog elapsed
Fault > CiA402 [1]
U8
-
onboard EtherCAT monitoring: EtherCAT role check
Warning [2]
U8
-
Safety interface: Control data
- (Read only)
U32
H
●
Safety interface: Status data
- (Read only)
U32
H
●
Safety interface: I/O status
- (Read only)
U32
H
●
Safety interface bits: STO active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SS1 active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SS2 active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SOS active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SLS1 active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SLS2 active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SLS3 active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SLS4 active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SDIpos active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SDIneg active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SLI active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SSE active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: ES active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: OMS active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: RMS active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SBC active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: MUT active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SLS1 observed
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SLS2 observed
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SLS3 observed
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SLS4 observed
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SMS observed
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SSM within limits
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SDIpos observed
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SDIneg observed
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SLP1 observed
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SLP2 observed
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SLP3 observed
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SLP4 observed
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SCA1 within limits
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SCA2 within limits
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SCA3 within limits
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SCA4 within limits
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: PDSSpos observed
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: PDSSneg observed
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SOS observed
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SBC activated
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SHom active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: SHom available
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: Safe speed OK
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: n=0
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: Positive direction
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: Slip > 25%
- (Read only)
BOOLEAN
1
-
Safety interface bits: Slip > 50%
- (Read only)
BOOLEAN
1
-
Safety interface bits: Slip > 75%
- (Read only)
BOOLEAN
1
-
Safety interface bits: Error active
- (Read only)
BOOLEAN
1
-
●
Safety interface bits: AIS S-Bus
- (Read only)
BOOLEAN
1
-
Safety interface bits: AIE S-Bus
- (Read only)
BOOLEAN
1
-
Safety interface bits: SHom_Start S-Bus
- (Read only)
BOOLEAN
1
-
Safety interface bits: SHom_Load S-Bus
- (Read only)
BOOLEAN
1
-
S-Bus control data
- (Read only)
U32
H
S-Bus control bits: STO
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SS1
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SS2
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SLS1
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SLS2
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SLS3
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SLS4
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SDIpos
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SDIneg
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: ES
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SLI
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: OMS
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SLP1
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SLP2
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SLP3
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SLP4
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: AIS
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: AIE
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SOS
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: RMS
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SHom_Start
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SHom_Load
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: PDSS
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SSE
- (Read only)
BOOLEAN
1
-
●
S-Bus control bits: SBC
- (Read only)
BOOLEAN
1
-
●
Safety motor encoder: System
No motor encoder [0]
U8
-
Safety motor encoder: SinCos encoder PPR
1
U16
1
-
Safety motor encoder: Number of resolver pole pairs
1
U8
1
-
Safety motor encoder: Response time encoder monitoring
50 [50]
U8
-
Safety motor encoder: Safety-HDSL driver state
- (Read only)
U16
H
Safety motor encoder: Safety HDSL online status 1
- (Read only)
U16
H
Safety motor encoder: Safety HDSL online status 2
- (Read only)
U16
H
Safety motor encoder: Safety HDSL Safe summary
- (Read only)
U8
H
Safety motor encoder: Safety HDSL Safe Channel 2 status
- (Read only)
U8
H
Safety motor encoder: Safety HDSL encoder status ENC_ST0
- (Read only)
U8
H
Safety motor encoder: Safety HDSL encoder status ENC_ST1
- (Read only)
U8
H
Safety motor encoder: Safety HDSL encoder status ENC_ST2
- (Read only)
U8
H
Safety motor encoder: Safety HDSL encoder status ENC_ST3
- (Read only)
U8
H
Safety motor encoder: Safety HDSL encoder status ENC_ST4
- (Read only)
U8
H
Safety motor encoder: Safety HDSL encoder status ENC_ST5
- (Read only)
U8
H
Safety motor encoder: Safety HDSL encoder status ENC_ST6
- (Read only)
U8
H
Safety motor encoder: Safety HDSL encoder status ENC_ST7
- (Read only)
U8
H
Mechanical data: Motor mounting direction
Motor rotating CW [0]
U8
-
Safety load encoder: System
No load encoder [0]
U8
-
Safety load encoder: Gear numerator
100
U16
1
-
Safety load encoder: Gear denominator
100
U16
1
-
Safety load encoder: Mounting direction
As motor encoder [0]
U8
-
Safety load encoder: Position
0 incr.
I32
1
-
●
Safety load encoder: Position status
Invalid [0]
U8
-
●
Safety load encoder: Additional gear numerator
1
U32
1
-
Safety load encoder: Additional gear denominator
1
U32
1
-
Speed: Tolerance window (n=0)
5 rpm
U16
1
-
Speed: Tolerance speed comparison
20 rpm
U16
1
-
Speed: Current speed n_safe
x rpm (Read only)
I16
1
-
●
Speed: Internal current speed nSD
x rpm (Read only)
I16
1
-
Speed: Internal current speed nBD
x rpm (Read only)
I16
1
-
Speed: Current speed difference nSD-nBD
x rpm (Read only)
I16
1
-
Position: Tolerance position comparison
8192 incr.
I32
1
-
Position: Current position p_safe
x incr. (Read only)
I32
1
-
●
Position: Internal current position pSD
x incr. (Read only)
I32
1
-
Position: Internal current position pBD
x incr. (Read only)
I32
1
-
Position: Current position difference pSD-pBD
x incr. (Read only)
I32
1
-
SHom_Start: Source
Disabled [0]
U8
-
SHom_Start: IRS edge trigger
Rising edge [0]
U8
-
SHom_Load: Source
IRL [15]
U8
-
SHom_Load: IRL edge trigger
Rising edge [0]
U8
-
SHom: Home position
0 incr.
I32
1
-
SHom: Timeout
0 ms
U16
1
-
SHom: SLS for homing
SLS1 [3]
U8
-
SHom: Restart condition
Homing required [0]
U8
-
SHom: Starting position tolerance
0 incr.
I32
1
-
SHom: Status
- (Read only)
U8
-
SHom: Saved position
x incr. (Read only)
I32
1
-
SHom Source diagnostic positions
Disabled [0]
U8
-
SHom: Level diagnostic positions
LOW level [0]
U8
-
SHom: Lower diagnostic position
0 incr.
I32
1
-
SHom: Upper diagnostic position
0 incr.
I32
1
-
SHom: Tolerance diagnostic positions
0 incr.
I32
1
-
SHom: Error response diagnostic positions
STO [0]
U8
-
SHom: Current difference diagnostic position
x incr. (Read only)
I32
1
-
SHom: Maximum compensated slip
0 incr.
I32
1
-
SHom: End area slip compensation
Disabled [0]
U8
-
SHom "SHom active" - Output
Disabled [0]
U8
-
SHom "SHom available" - Output
Disabled [0]
U8
-
STO Source SD-In
SD-In1 [1]
U8
-
STO Source S-Bus
Disabled [0]
U8
-
STO: Restart
Automatic restart [1]
U8
-
STO "STO active" - Output
Disabled [0]
U8
-
SS1, SS2: Stopping time
0 ms
U16
1
-
SS1, SS2: Ramp monitoring
Disabled [0]
U8
-
SS1, SS2: Ramp - Smoothing time
0 %
U8
1
-
SS1, SS2: Ramp - Offset mode
Relativ [0]
U8
-
SS1, SS2: Ramp - Start-offset relative
5 %
U8
1
-
SS1, SS2: Ramp - Start-offset absolute
0 rpm
U16
1
-
SS1, SS2: Ramp - Currently monitored speed
x rpm (Read only)
U16
1
-
SS1, SS2: Ramp - Minimum difference
x rpm (Read only)
I16
1
-
SS1 Source SD-In
Disabled [0]
U8
-
SS1 Source S-Bus
Disabled [0]
U8
-
SS1: Mode
STO after stopping time [0]
U8
-
SS1: Delay STO after n=0
0 ms
U16
1
-
SS1 "SS1 active" - Output
Disabled [0]
U8
-
SS2 Source SD-In
Disabled [0]
U8
-
SS2 Source S-Bus
Disabled [0]
U8
-
SS2: Mode
SOS after stopping time [0]
U8
-
SS2 "SS2 active" - Output
Disabled [0]
U8
-
SOS Source SD-In
Disabled [0]
U8
-
SOS Source S-Bus
Disabled [0]
U8
-
SOS: Tolerance window (Delta p=0)
8192 incr.
I32
1
-
SOS: Restart
Acknowledged restart [0]
U8
-
SOS: Maximum change of position
x incr. (Read only)
I32
1
-
SOS "SOS observed" - Output
Disabled [0]
U8
-
SSE Source SD-In
Disabled [0]
U8
-
SSE Source S-Bus
Disabled [0]
U8
-
SSE: Emergency stop function
STO [0]
U8
-
SSE "SSE active" - Output
Disabled [0]
U8
-
OMS Source
Disabled [0]
U8
-
OMS: Stop function
STO [0]
U8
-
OMS: Motion function
Free mode [11]
U8
-
OMS: Function at low level
Normal operation [0]
U8
-
OMS "OMS active" - Output
Disabled [0]
U8
-
RMS Source
Disabled [0]
U8
-
RMS: Stop function
STO [0]
U8
-
RMS "RMS active" - Output
Disabled [0]
U8
-
ES Source
Disabled [0]
U8
-
ES "ES active" - Output
Disabled [0]
U8
-
SMS: Maximum speed Nmax
0 rpm
U16
1
-
SMS: Response (n>Nmax)
STO [0]
U8
-
SMS "SMS observed" - Output
Disabled [0]
U8
-
SSM: Monitored speed
0 rpm
U16
1
-
SSM "SSM within limits" - Output
Disabled [0]
U8
-
SDI: SDIpos - Source SD-In
Disabled [0]
U8
-
SDI: SDIneg - Source SD-In
Disabled [0]
U8
-
SDI: SDIpos - Source S-Bus
Disabled [0]
U8
-
SDI: SDIneg - Source S-Bus
Disabled [0]
U8
-
SDI: Monitoring standard operation
Both directions enabled [0]
U8
-
SDI: Delay time
0 ms
U16
1
-
SDI: Tolerance threshold
8192 incr.
I32
1
-
SDI: Error response
STO [0]
U8
-
SDI: Maximum change of position
x incr. (Read only)
I32
1
-
SDI: "SDIpos observed" - Output
Disabled [0]
U8
-
SDI: "SDIneg observed" - Output
Disabled [0]
U8
-
SLS: SLS1 - Internal source
Disabled [0]
U32
-
SLS: SLS1 - Internal source inversion
Not inverted [0]
U8
-
SLS: SLS2 - Internal source
Disabled [0]
U32
-
SLS: SLS2 - Internal source inversion
Not inverted [0]
U8
-
SLS: SLS3 - Internal source
Disabled [0]
U32
-
SLS: SLS3 - Internal source inversion
Not inverted [0]
U8
-
SLS: SLS4 - Internal source
Disabled [0]
U32
-
SLS: SLS4 - Internal source inversion
Not inverted [0]
U8
-
SLS: SLS1 - Source SD-In
Disabled [0]
U8
-
SLS: SLS2 - Source SD-In
Disabled [0]
U8
-
SLS: SLS3 - Source SD-In
Disabled [0]
U8
-
SLS: SLS4 - Source SD-In
Disabled [0]
U8
-
SLS: SLS1 - Source S-Bus
Disabled [0]
U8
-
SLS: SLS2 - Source S-Bus
Disabled [0]
U8
-
SLS: SLS3 - Source S-Bus
Disabled [0]
U8
-
SLS: SLS4 - Source S-Bus
Disabled [0]
U8
-
SLS: SLS1 - Limited speed Nlim1
0 rpm
U16
1
-
SLS: SLS2 - Limited speed Nlim2
0 rpm
U16
1
-
SLS: SLS3 - Limited speed Nlim3
0 rpm
U16
1
-
SLS: SLS4 - Limited speed Nlim4
0 rpm
U16
1
-
SLS: SLS1 - Braking time Nlim1
0 ms
U16
1
-
SLS: SLS2 - Braking time Nlim2
0 ms
U16
1
-
SLS: SLS3 - Braking time Nlim3
0 ms
U16
1
-
SLS: SLS4 - Braking time Nlim4
0 ms
U16
1
-
SLS: SLS1 - Permitted direction
Both directions enabled [0]
U8
-
SLS: SLS2 - Permitted direction
Enable both directions [0]
U8
-
SLS: SLS3 - Permitted direction
Enable both directions [0]
U8
-
SLS: SLS4 - Permitted direction
Enable both directions [0]
U8
-
SLS: SLS1 - Response (n>Nlim1)
STO [0]
U8
-
SLS: SLS2 - Response (n>Nlim2)
STO [0]
U8
-
SLS: SLS3 - Response (n>Nlim3)
STO [0]
U8
-
SLS: SLS4 - Response (n>Nlim4)
STO [0]
U8
-
SLS: "SLS1 active" - Output
Disabled [0]
U8
-
SLS: "SLS2 active" - Output
Disabled [0]
U8
-
SLS: "SLS3 active" - Output
Disabled [0]
U8
-
SLS: "SLS4 active" - Output
Disabled [0]
U8
-
SLS: "SLS1 observed" - Output
Disabled [0]
U8
-
SLS: "SLS2 observed" - Output
Disabled [0]
U8
-
SLS: "SLS3 observed" - Output
Disabled [0]
U8
-
SLS: "SLS4 observed" - Output
Disabled [0]
U8
-
SLI Source SD-In
Disabled [0]
U8
-
SLI Source S-Bus
Disabled [0]
U8
-
SLI: Increment size standard operation
0 incr.
I32
1
-
SLI: Error response standard operation
STO [0]
U8
-
SLI: Increment size special operation
0 incr.
I32
1
-
SLI: Maximum change of position
x incr. (Read only)
I32
1
-
SLI "SLI active" - Output
Disabled [0]
U8
-
SLP: SLP1 - Source SD-In
Disabled [0]
U8
-
SLP: SLP2 - Source SD-In
Disabled [0]
U8
-
SLP: SLP3 - Source SD-In
Disabled [0]
U8
-
SLP: SLP4 - Source SD-In
Disabled [0]
U8
-
SLP: SLP1 - Source S-Bus
Disabled [0]
U8
-
SLP: SLP2 - Source S-Bus
Disabled [0]
U8
-
SLP: SLP3 - Source S-Bus
Disabled [0]
U8
-
SLP: SLP4 - Source S-Bus
Disabled [0]
U8
-
SLP: SLP1 - Lower position limit
0 incr.
I32
1
-
SLP: SLP2 - Lower position limit
0 incr.
I32
1
-
SLP: SLP3 - Lower position limit
0 incr.
I32
1
-
SLP: SLP4 - Lower position limit
0 incr.
I32
1
-
SLP: SLP1 - Upper position limit
0 incr.
I32
1
-
SLP: SLP2 - Upper position limit
0 incr.
I32
1
-
SLP: SLP3 - Upper position limit
0 incr.
I32
1
-
SLP: SLP4 - Upper position limit
0 incr.
I32
1
-
SLP: SLP1 - Error response
STO [0]
U8
-
SLP: SLP2 - Error response
STO [0]
U8
-
SLP: SLP3 - Error response
STO [0]
U8
-
SLP: SLP4 - Error response
STO [0]
U8
-
SLP: "SLP1 observed" - Output
Disabled [0]
U8
-
SLP: "SLP2 observed" - Output
Disabled [0]
U8
-
SLP: "SLP3 observed" - Output
Disabled [0]
U8
-
SLP: "SLP4 observed" - Output
Disabled [0]
U8
-
SCA: SCA1 - Lower position limit
0 incr.
I32
1
-
SCA: SCA2 - Lower position limit
0 incr.
I32
1
-
SCA: SCA3 - Lower position limit
0 incr.
I32
1
-
SCA: SCA4 - Lower position limit
0 incr.
I32
1
-
SCA: SCA1 - Upper position limit
0 incr.
I32
1
-
SCA: SCA2 - Upper position limit
0 incr.
I32
1
-
SCA: SCA3 - Upper position limit
0 incr.
I32
1
-
SCA: SCA4 - Upper position limit
0 incr.
I32
1
-
SCA: "SCA1 within limits" - Output
Disabled [0]
U8
-
SCA: "SCA2 within limits" - Output
Disabled [0]
U8
-
SCA: "SCA3 within limits" - Output
Disabled [0]
U8
-
SCA: "SCA4 within limits" - Output
Disabled [0]
U8
-
PDSS Source SD-In
Disabled [0]
U8
-
PDSS Source S-Bus
Disabled [0]
U8
-
PDSS: Permanent activation
On demand [0]
U8
-
PDSS: Lower position limit
0 incr.
I32
1
-
PDSS: Upper position limit
0 incr.
I32
1
-
PDSS: Lower SCS limit
0 incr.
I32
1
-
PDSS: Upper SCS limit
0 incr.
I32
1
-
PDSS: SCS from lower limit
0 rpm
U16
1
-
PDSS: SCS from upper limit
0 rpm
U16
1
-
PDSS: Maximum speed
0 rpm
U16
1
-
PDSS: Maximum deceleration lower limit
0
U16
1
-
PDSS: Maximum deceleration upper limit
0
U16
1
-
PDSS: Error response
STO [0]
U8
-
PDSS: Currently monitored speed
x rpm (Read only)
U16
1
-
PDSS: Minimum difference monitored speed
x rpm (Read only)
I16
1
-
PDSS "PDSSpos observed" - Output
Disabled [0]
U8
-
PDSS "PDSSneg observed" - Output
Disabled [0]
U8
-
SBC Source SD-In
Disabled [0]
U8
-
SBC Source S-Bus
Disabled [0]
U8
-
SBC: Brake mode
SBC without STO [1]
U8
-
SBC: Delay SBC
0 ms
U16
1
-
SBC: Delay STO
0 ms
U16
1
-
SBC: Brake open delay
0 ms
U16
1
-
SBC: "SBC active" - Output
Disabled [0]
U8
-
SBC: "SBC activated" - Output
Disabled [0]
U8
-
Diagnostic: Configuration diagnostic value 1
PDSS - Current monitored speed [1]
U16
-
Diagnostic: Configuration diagnostic value 2
SS1, SS2 - Current speed ramp [2]
U16
-
Diagnostic: Diagnostic value 1
- (Read only)
I16
1
-
●
Diagnostic: Diagnostic value 2
- (Read only)
I16
1
-
●
Speed controller settings: Gain
0.00033 Nm/rpm
U32
100000
-
Speed controller settings: Reset time
17.6 ms
U16
10
-
Speed controller settings: Rate time
0.00 ms
U16
100
-
Speed controller gain adaption
100.00 %
U16
100
-
●
I component load value
0.0 %
I16
10
-
●
Speed setpoint filter time
0.0 ms
U16
10
-
Actual speed filter time
0.3 ms
U16
10
-
Additional speed limitation
0 rpm
U32
1
-
●
Inertia settings: Motor moment of inertia
0.14 kg cm²
U32
100
-
Inertia settings: Scaled load inertia
0.00 kg cm²
U32
100
-
Inertia settings: Coupling
Stiff [0]
U8
-
Inertia settings: Mechanical natural frequency
0.0 Hz
U16
10
-
Inertia settings: Load moment of inertia (elastic coupled)
0.00 kg cm²
U32
100
-
Following error diagnostics: Following error (interval) - Time
1000 ms
U16
1
-
Following error diagnostics: Following error (interval) - Mean value
x.xx ° (Read only)
U32
100
-
Following error diagnostics: Following error (interval) - Maximum value
x.xx ° (Read only)
U32
100
-
Following error diagnostics: Following error (manual) - Start/Stop
Stop [0]
U8
-
Following error diagnostics: Following error (manual) - Mean value
x.xx ° (Read only)
U32
100
-
Following error diagnostics: Following error (manual) - Maximum value
x.xx ° (Read only)
U32
100
-
Following error diagnostics: Following error (standstill-standstill) - Mean value
x.xx ° (Read only)
U32
100
-
Following error diagnostics: Following error (standstill-standstill) - Maximum value
x.xx ° (Read only)
U32
100
-
0x2923:001
Internal: Activation
Off [0]
U8
C
0x2923:002
Internal: Type of load
Simple speed load [0]
U8
-
0x2923:003
Internal: Set load torque
0.0 %
I16
10
-
●
0x2923:004
Internal: Set load speed
0 rpm
I32
480000/2147483647
-
●
0x2923:005
Internal: Load moment of inertia
0.00 kg cm²
U32
100
-
0x2923:006
Internal: Friction coefficient
1.0 %
U32
10
-
0x2923:010
Internal: Identified total ramp-up time
0.000 ms
U32
1000
-
0x2923:011
Internal: Identified factor
1.000000
I32
1000000
-
0x2923:012
Internal: Identified current control - delay time
0.0
I32
10
-
0x2923:013
Internal: Identified current control - T1
0.0
I32
10
-
0x2923:014
Internal: Identified current control - T2
0.0
I32
10
-
0x2923:017
Internal: Identified root 1 - real part
0.000 1/s
I32
1000
-
0x2923:018
Internal: Identified root 1 - imaginary part
0.000 1/s
I32
1000
-
0x2923:019
Internal: Identified root 2 - real part
0.000 1/s
I32
1000
-
0x2923:020
Internal: Identified root 2 - imaginary part
0.000 1/s
I32
1000
-
0x2923:021
Internal: Identified root 3 - real part
0.000 1/s
I32
1000
-
0x2923:022
Internal: Identified root 3 - imaginary part
0.000 1/s
I32
1000
-
0x2923:023
Internal: Identified root 4 - real part
0.000 1/s
I32
1000
-
0x2923:024
Internal: Identified root 4 - imaginary part
0.000 1/s
I32
1000
-
0x2923:029
Internal: Identified pole 1 - real part
0.000 1/s
I32
1000
-
0x2923:030
Internal: Identified pole 1 - imaginary part
0.000 1/s
I32
1000
-
0x2923:031
Internal: Identified pole 2 - real part
0.000 1/s
I32
1000
-
0x2923:032
Internal: Identified pole 2 - imaginary part
0.000 1/s
I32
1000
-
0x2923:033
Internal: Identified pole 3 - real part
0.000 1/s
I32
1000
-
0x2923:034
Internal: Identified pole 3 - imaginary part
0.000 1/s
I32
1000
-
0x2923:035
Internal: Identified pole 4 - real part
0.000 1/s
I32
1000
-
0x2923:036
Internal: Identified pole 4 - imaginary part
0.000 1/s
I32
1000
-
0x2923:050
Internal: Identified result - motor moment of inertia
0.00 kg cm²
U32
100
-
0x2923:051
Internal: Identified result - load 1 moment of inertia
0.00 kg cm²
U32
100
-
0x2923:052
Internal: Identified result - load 2 moment of inertia
0.00 kg cm²
U32
100
-
0x2923:054
Internal: Identified result - coupling between motor and load 1
0.00
U32
100
-
0x2923:055
Internal: Identified result - coupling between load 1 and load 2
0.00
U32
100
-
0x2923:057
Internal: Identified result - damping between motor and load 1
0.00
U32
100
-
0x2923:058
Internal: Identified result - damping between load 1 and load 2
0.00
U32
100
-
Switching frequency
4 kHz variable / drive-optimised [1]
U8
-
Current controller feedforward control
Disable [0]
U8
-
Current controller parameters: Gain
148.21 V/A
U32
100
-
Current controller parameters: Reset time
3.77 ms
U32
100
-
Current setpoint filter time
0.00 ms
U16
100
-
Torque setpoint notch filter: Frequency notch filter 1
200.0 Hz
U16
10
-
Torque setpoint notch filter: Bandwidth notch filter 1
20.0 Hz
U16
10
-
Torque setpoint notch filter: Damping notch filter 1
0 dB
U8
1
-
Torque setpoint notch filter: Frequency notch filter 2
400.0 Hz
U16
10
-
Torque setpoint notch filter: Bandwidth notch filter 2
40.0 Hz
U16
10
-
Torque setpoint notch filter: Damping notch filter 2
0 dB
U8
1
-
Torque setpoint jerk limitation
400.0
U16
10
-
Speed limitation: Upper speed limit
0 rpm
I32
480000/2147483647
-
●
Speed limitation: Lower speed limit
0 rpm
I32
480000/2147483647
-
●
Inverter characteristic: Value y1
0.00 V
U16
100
-
Inverter characteristic: Value y2
0.00 V
U16
100
-
Inverter characteristic: Value y3
0.00 V
U16
100
-
Inverter characteristic: Value y4
0.00 V
U16
100
-
Inverter characteristic: Value y5
0.00 V
U16
100
-
Inverter characteristic: Value y6
0.00 V
U16
100
-
Inverter characteristic: Value y7
0.00 V
U16
100
-
Inverter characteristic: Value y8
0.00 V
U16
100
-
Inverter characteristic: Value y9
0.00 V
U16
100
-
Inverter characteristic: Value y10
0.00 V
U16
100
-
Inverter characteristic: Value y11
0.00 V
U16
100
-
Inverter characteristic: Value y12
0.00 V
U16
100
-
Inverter characteristic: Value y13
0.00 V
U16
100
-
Inverter characteristic: Value y14
0.00 V
U16
100
-
Inverter characteristic: Value y15
0.00 V
U16
100
-
Inverter characteristic: Value y16
0.00 V
U16
100
-
Inverter characteristic: Value y17
0.00 V
U16
100
-
Torque limits offset: Torque offset
0.0 %
I16
10
-
Torque limits offset: Resulting positive torque limit
x.x % (Read only)
I16
10
-
Torque limits offset: Resulting negative torque limit
x.x % (Read only)
I16
10
-
Position controller gain
28.40 1/s
U32
100
-
Position controller gain adaption
100.00 %
U16
100
-
●
Position controller output signal limitation
480000.00 rpm
U32
480000/2147483647
-
●
Actual position start value
0
I32
1
-
●
Mode for setting the actual position
Absolute [0]
U8
-
Resulting gain adaption
x.xx % (Read only)
U32
100
-
Field controller settings: Gain
165.84 A/Vs
U32
100
-
Field controller settings: Reset time
15.1 ms
U16
10
-
Field weakening controller settings: Gain (ASM)
0.000 Vs/V
U32
1000
-
Field weakening controller settings: Reset time (ASM)
2000.0 ms
U32
10
-
Field weakening controller Field limitation
100.00 %
U16
100
-
●
DC-bus filter time
25.0 ms
U16
10
-
Motor voltage filter time
25.0 ms
U16
10
-
Voltage reserve range
5 %
U8
1
-
V/f characteristic shape
Linear [0]
U8
C
V/f shape data: Base voltage
225 V
U16
1
-
V/f shape data: Base frequency
270 Hz
U16
1
-
Frequency grid points (x) user V/f characteristic: x1 = f01
-50 Hz
I16
1
-
Frequency grid points (x) user V/f characteristic: x2 = f02
-40 Hz
I16
1
-
Frequency grid points (x) user V/f characteristic: x3 = f03
-30 Hz
I16
1
-
Frequency grid points (x) user V/f characteristic: x4 = f04
-20 Hz
I16
1
-
Frequency grid points (x) user V/f characteristic: x5 = f05
-10 Hz
I16
1
-
Frequency grid points (x) user V/f characteristic: x6 = f06
0 Hz
I16
1
-
Frequency grid points (x) user V/f characteristic: x7 = f07
10 Hz
I16
1
-
Frequency grid points (x) user V/f characteristic: x8 = f08
20 Hz
I16
1
-
Frequency grid points (x) user V/f characteristic: x9 = f09
30 Hz
I16
1
-
Frequency grid points (x) user V/f characteristic: x10 = f10
40 Hz
I16
1
-
Frequency grid points (x) user V/f characteristic: x11 = f11
50 Hz
I16
1
-
Voltage grid points (y) user V/f characteristic: y1 = U01 (x = f01)
400.00 V
U32
100
-
Voltage grid points (y) user V/f characteristic: y2 = U02 (x = f02)
320.00 V
U32
100
-
Voltage grid points (y) user V/f characteristic: y3 = U03 (x = f03)
240.00 V
U32
100
-
Voltage grid points (y) user V/f characteristic: y4 = U04 (x = f04)
160.00 V
U32
100
-
Voltage grid points (y) user V/f characteristic: y5 = U05 (x = f05)
80.00 V
U32
100
-
Voltage grid points (y) user V/f characteristic: y6 = U06 (x = f06)
0.00 V
U32
100
-
Voltage grid points (y) user V/f characteristic: y7 = U07 (x = f07)
80.00 V
U32
100
-
Voltage grid points (y) user V/f characteristic: y8 = U08 (x = f08)
160.00 V
U32
100
-
Voltage grid points (y) user V/f characteristic: y9 = U09 (x = f09)
240.00 V
U32
100
-
Voltage grid points (y) user V/f characteristic: y10 = U10 (x = f10)
320.00 V
U32
100
-
Voltage grid points (y) user V/f characteristic: y11 = U11 (x = f11)
400.00 V
U32
100
-
V/f boost controller - current setpoint
0.00 A
U32
100
-
V/f boost controller settings: Gain
148.21 V/A
U32
100
-
V/f boost controller settings: Reset time
3.77 ms
U32
100
-
V/f boost controller settings: Dynamic current setpoint
0.00 A
U32
100
-
Voltage boost
0.0 V
U16
10
-
Load adaption: Direction of rotation
Passive load [0]
U8
C
Load adaption: Load adaption value
20.00 %
U32
100
-
V/f Imax controller: Gain
0.001 Hz/A
U32
1000
-
V/f Imax controller: Reset time
100.0 ms
U32
10
-
Slip compensation: Gain
0.00 %
I16
100
-
Slip compensation: Filter time
2000 ms
U16
1
-
Oscillation damping: Gain
20 %
I16
1
-
Oscillation damping: Filter time
5 ms
U16
1
-
Oscillation damping: Limitation
0.2 Hz
U16
10
-
Oscillation damping: Final ramp frequency
0 %
U8
1
-
Ramp generator frequency
x.x Hz (Read only)
I16
10
-
●
Override field weakening
0.0 Hz
I16
10
-
Gain
0.100
U16
1000
-
Reset time
100.0 ms
U16
10
-
Frequency limitation
10.00 Hz
U16
100
-
Current for DC-injection braking
0.00 A
U16
100
-
Activate flying restart
Off [0]
U8
-
Flying restart circuit
15 %
U16
1
-
Start frequency
20.0 Hz
I16
10
-
Integration time
600 ms
U16
1
-
Minimum deviation
5.00 °
U16
100
-
Delay time
0 ms
U16
1
-
Result: Determined speed [rpm]
x rpm (Read only)
I16
1
-
●
Result: Determined speed [n unit]
rpm (Read only)
I32
480000/2147483647
-
●
Motor control mode
Servoregelung (SC-PSM) [1]
U8
C
Motor parameters: Number of pole pairs
- (Read only)
U8
1
-
Motor parameters: Stator resistance
13.5000 Ω
U32
10000
-
Motor parameters: Stator leakage inductance
51.000 mH
U32
1000
-
Motor parameters: Rated speed
4050 rpm
U16
1
-
Motor parameters: Rated frequency
270.0 Hz
U16
10
-
Motor parameters: Rated power
0.25 kW
U16
100
-
Motor parameters: Rated voltage
225 V
U16
1
-
Motor parameters: Cosine phi
0.80
U16
100
-
Motor parameters: Insulation class
F (cut-off temperature = 155 °C) [4]
U8
-
Motor parameters: Motor name
"MCS06C41"
STRING[50]
-
Motor parameter (ASM): Rotor resistance
0.0000 Ω
U32
10000
-
Motor parameter (ASM): Mutual inductance
0.0 mH
U32
10
-
Motor parameter (ASM): Magnetising current
0.00 A
U16
100
-
Motor parameter (PSM): Back EMF constant
41.8 V/1000rpm
U32
10
-
Motor parameter (PSM): Resolver pole position
-90.0 °
I16
10
-
Motor parameter (PSM): Magnets temperature coefficient (kTN)
-0.110 %/°C
I16
1000
-
Motor parameter (PSM): Encoder pole position
0.0 °
I16
10
-
d-axis Lss saturation characteristic: y1 = L01 (x = 0.00 %)
165 %
U16
1
-
d-axis Lss saturation characteristic: y2 = L02 (x = 6.25 %)
200 %
U16
1
-
d-axis Lss saturation characteristic: y3 = L03 (x = 12.50 %)
146 %
U16
1
-
d-axis Lss saturation characteristic: y4 = L04 (x = 18.75 %)
117 %
U16
1
-
d-axis Lss saturation characteristic: y5 = L05 (x = 25.00 %)
97 %
U16
1
-
d-axis Lss saturation characteristic: y6 = L06 (x = 31.25 %)
82 %
U16
1
-
d-axis Lss saturation characteristic: y7 = L07 (x = 37.50 %)
71 %
U16
1
-
d-axis Lss saturation characteristic: y8 = L08 (x = 42.75 %)
62 %
U16
1
-
d-axis Lss saturation characteristic: y9 = L09 (x = 50.00 %)
55 %
U16
1
-
d-axis Lss saturation characteristic: y10 = L10 (x = 56.25 %)
50 %
U16
1
-
d-axis Lss saturation characteristic: y11 = L11 (x = 62.50 %)
46 %
U16
1
-
d-axis Lss saturation characteristic: y12 = L12 (x = 68.75 %)
43 %
U16
1
-
d-axis Lss saturation characteristic: y13 = L13 (x = 75.00 %)
42 %
U16
1
-
d-axis Lss saturation characteristic: y14 = L14 (x = 81.25 %)
41 %
U16
1
-
d-axis Lss saturation characteristic: y15 = L15 (x = 87.50 %)
41 %
U16
1
-
d-axis Lss saturation characteristic: y16 = L16 (x = 93.25 %)
41 %
U16
1
-
d-axis Lss saturation characteristic: y17 = L17 (x = 100.00 %)
41 %
U16
1
-
d-axis Lss saturation characteristic: Activation Lss saturation characteristic
Adjustment on [1]
U16
-
0x2C04:019
d-axis Lss saturation characteristic: Cross saturation factor
0 %
U16
1
-
Reference for current grid points (x) Lss saturation characteristic
5.4 A
U16
10
-
Grid points for magnet characteristic (current): x1 = i01/iN
0 %
U16
1
-
Grid points for magnet characteristic (current): y1 = kT01/kTN
100 %
U16
1
-
Grid points for magnet characteristic (current): x2 = i02/iN
100 %
U16
1
-
Grid points for magnet characteristic (current): y2 = kT02/kTN
100 %
U16
1
-
Grid points for magnet characteristic (current): x3 = i03/iN
200 %
U16
1
-
Grid points for magnet characteristic (current): y3 = kT03/kTN
100 %
U16
1
-
Grid points for magnet characteristic (current): x4 = i04/iN
415 %
U16
1
-
Grid points for magnet characteristic (current): y4 = kT04/kTN
72 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y1 = L01 (x = 0.00 %)
118 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y2 = L02 (x = 6.25 %)
118 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y3 = L03 (x = 12.50 %)
118 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y4 = L04 (x = 18.75 %)
117 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y5 = L05 (x = 25.00 %)
116 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y6 = L06 (x = 31.25 %)
114 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y7 = L07 (x = 37.50 %)
111 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y8 = L08 (x = 43.75 %)
107 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y9 = L09 (x = 50.00 %)
100 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y10 = L10 (x = 56.25 %)
93 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y11 = L11 (x = 62.50 %)
86 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y12 = L12 (x = 68.75 %)
78 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y13 = L13 (x = 75.00 %)
71 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y14 = L14 (x = 81.25 %)
64 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y15 = L15 (x = 87.50 %)
57 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y16 = L16 (x = 93.75 %)
50 %
U16
1
-
Inductance grid points (y) Lh saturation characteristic: y17 = L17 (x = 100.00 %)
42 %
U16
1
-
Method for setting motor parameters
Select from catalogue (Lenze motors) [1]
U8
-
0x2C09:001
q-axis Lss saturation characteristic: y1 = L01 (x = 0.00 %)
165 %
U16
1
-
0x2C09:003
q-axis Lss saturation characteristic: y3 = L03 (x = 12.50 %)
146 %
U16
1
-
0x2C09:004
q-axis Lss saturation characteristic: y4 = L04 (x = 18.75 %)
117 %
U16
1
-
0x2C09:005
q-axis Lss saturation characteristic: y5 = L05 (x = 25.00 %)
97 %
U16
1
-
0x2C09:006
q-axis Lss saturation characteristic: y6 = L06 (x = 31.25 %)
82 %
U16
1
-
0x2C09:007
q-axis Lss saturation characteristic: y7 = L07 (x = 37.50 %)
71 %
U16
1
-
0x2C09:008
q-axis Lss saturation characteristic: y8 = L08 (x = 42.75 %)
62 %
U16
1
-
0x2C09:009
q-axis Lss saturation characteristic: y9 = L09 (x = 50.00 %)
55 %
U16
1
-
0x2C09:010
q-axis Lss saturation characteristic: y10 = L10 (x = 56.25 %)
50 %
U16
1
-
0x2C09:011
q-axis Lss saturation characteristic: y11 = L11 (x = 62.50 %)
46 %
U16
1
-
0x2C09:012
q-axis Lss saturation characteristic: y12 = L12 (x = 68.75 %)
43 %
U16
1
-
0x2C09:013
q-axis Lss saturation characteristic: y13 = L13 (x = 75.00 %)
42 %
U16
1
-
0x2C09:014
q-axis Lss saturation characteristic: y14 = L14 (x = 81.25 %)
41 %
U16
1
-
0x2C09:015
q-axis Lss saturation characteristic: y15 = L15 (x = 87.50 %)
41 %
U16
1
-
0x2C09:016
q-axis Lss saturation characteristic: y16 = L16 (x = 93.25 %)
41 %
U16
1
-
0x2C09:017
q-axis Lss saturation characteristic: y17 = L17 (x = 100.00 %)
41 %
U16
1
-
0x2C09:018
q-axis Lss saturation characteristic: Table source
Identical to d-axis (0x2C04) [0]
U16
-
0x2C16:001
Cogging torque compensation: Enable compensation
On [1]
U8
-
0x2C16:002
Cogging torque compensation: Commutation turns
1
U8
1
-
0x2C16:003
Cogging torque compensation: Max. recommended identification speed
x rpm (Read only)
U16
1
-
0x2C16:004
Cogging torque compensation: Max. compensation speed
[13]
U8
-
0x2C16:005
Cogging torque compensation: Identification state
- (Read only)
U16
H
0x2C16:006
Cogging torque compensation: Amplitude 1
0.000 %
I16
1000
C
0x2C16:007
Cogging torque compensation: Phase 1
0.0 °
I16
10
C
0x2C16:008
Cogging torque compensation: Amplitude 2
0.000 %
I16
1000
C
0x2C16:009
Cogging torque compensation: Phase 2
0.0 °
I16
10
C
0x2C16:010
Cogging torque compensation: Amplitude 3
0.000 %
I16
1000
C
0x2C16:011
Cogging torque compensation: Phase 3
0.0 °
I16
10
C
0x2C16:012
Cogging torque compensation: Amplitude 4
0.000 %
I16
1000
C
0x2C16:013
Cogging torque compensation: Phase 4
0.0 °
I16
10
C
0x2C16:014
Cogging torque compensation: Amplitude 5
0.000 %
I16
1000
C
0x2C16:015
Cogging torque compensation: Phase 5
0.0 °
I16
10
C
0x2C16:016
Cogging torque compensation: Amplitude 6
0.000 %
I16
1000
C
0x2C16:017
Cogging torque compensation: Phase 6
0.0 °
I16
10
C
0x2C16:018
Cogging torque compensation: Amplitude 7
0.000 %
I16
1000
C
0x2C16:019
Cogging torque compensation: Phase 7
0.0 °
I16
10
C
0x2C16:020
Cogging torque compensation: Amplitude 8
0.000 %
I16
1000
C
0x2C16:021
Cogging torque compensation: Phase 8
0.0 °
I16
10
C
0x2C16:022
Cogging torque compensation: Amplitude 9
0.000 %
I16
1000
C
0x2C16:023
Cogging torque compensation: Phase 9
0.0 °
I16
10
C
0x2C16:024
Cogging torque compensation: Amplitude 10
0.000 %
I16
1000
C
0x2C16:025
Cogging torque compensation: Phase 10
0.0 °
I16
10
C
Motor encoder type
SinCos encoder [1]
U8
C
Motor encoder settings (HIPERFACE®): Type code detected
- (Read only)
U8
1
-
Motor encoder settings (HIPERFACE®): Type code manual input
0
U8
1
C
Motor encoder settings (HIPERFACE®): Manual input - Number of detectable motor encoder revolutions
1
U16
1
C
Motor encoder settings (HIPERFACE®): Error response
Fault > CiA402 [1]
U8
-
Motor encoder settings (HIPERFACE®): Serial number
- (Read only)
STRING[50]
-
Motor encoder settings (HIPERFACE®): Actual position (raw data)
- (Read only)
U32
1
-
●
Motor encoder settings (HIPERFACE®): No. of periods detected
- (Read only)
U16
1
-
●
Motor encoder settings (HIPERFACE®): Type code verification
- (Read only)
U8
-
●
Motor encoder settings (HIPERFACE®): Encoder type
- (Read only)
U8
-
●
Motor encoder settings (HIPERFACE®): Period length of linear encoder
x nm (Read only)
U32
1
-
●
Encoder settings: Increments/revolution
1024
U32
1
C
Encoder settings: Supply voltage
5.0 V
U8
10
C
Encoder settings: Angle drift
x.x ° (Read only)
I16
10
-
●
Encoder settings: Actual amplitude signal quality
x % (Read only)
U8
1
-
Encoder settings: Encoder voltage cos track
x.xxx V (Read only)
I16
1000
-
Encoder settings: Encoder voltage sin track
x.xxx V (Read only)
I16
1000
-
Encoder settings: TTL/HTL signal evaluation
High resolution encoder - 4-fold evaluation [1]
U8
C
Motor encoder resolver number of pole pairs
1
U8
1
C
Motor encoder identification (Resolver): Angle
0
I16
1
-
Motor encoder identification (Resolver): Cosine track gain
100 %
U16
1
-
Motor encoder identification (Resolver): Sine track gain
100 %
U16
1
-
Motor encoder identification (Resolver): Identification status
- (Read only)
U16
H
Motor encoder identification (Resolver): Cosine track offset
0.000 %
I32
1000
-
Motor encoder identification (Resolver): Sine track offset
0.000 %
I32
1000
-
Motor encoder identification (Resolver): Cyclic online compensation
[1]
U8
-
Motor encoder identification (Resolver): Harmonic for cyclic online compensation
22
U16
1
-
Motor encoder identification (Resolver): Dead time compensation resolver evaluation
100.0 %
I16
10
-
Motor feedback error response
Fault > CiA402 [1]
U8
-
Number of the absolute ascertainable revolutions of motor encoder
- (Read only)
U16
1
-
Open circuit detection sensitivity of motor encoder
100 %
U8
1
-
Motor encoder (EnDat): Response communication error
Fault > CiA402 [1]
U8
-
Motor encoder (EnDat): Actual position (raw data)
- (Read only)
U32
1
-
●
Motor encoder (EnDat): Serial number
- (Read only)
STRING[50]
-
Motor encoder (EnDat): ID number
- (Read only)
STRING[50]
-
Motor encoder (EnDat): Encoder designation
- (Read only)
STRING[50]
-
Motor encoder (EnDat): EnDat ordering designation
- (Read only)
STRING[50]
-
Motor encoder (EnDat): EnDat command set
- (Read only)
STRING[50]
-
Motor encoder (EnDat): Encoder type
- (Read only)
U8
1
-
Motor encoder (EnDat): Signal periods per revolution/Length of signal period
- (Read only)
U32
1
-
Motor encoder (EnDat): Distinguishable revolutions
- (Read only)
U16
1
-
Motor encoder (EnDat): Max. clock frequency
x kHz (Read only)
U16
1
-
Motor encoder (EnDat): Measuring step or measuring steps/rev for serial data transmission
- (Read only)
U32
1
-
Motor encoder (EnDat): Scaling factor for resolution
- (Read only)
U16
1
-
Motor encoder (EnDat): Measuring step, or measuring steps/rev or subdivision values of a grating period
- (Read only)
U32
1
-
Motor encoder (SSI) protocol parameters: Bit rate
300 kbps
U16
1
C
Motor encoder (SSI) protocol parameters: Telegram length
25
U8
1
C
Motor encoder (SSI) protocol parameters: Bits/revolution
13
U8
1
C
Motor encoder (SSI) protocol parameters: Position data start bit
0
U8
1
C
Motor encoder (SSI) protocol parameters: Data package 1 start bit
0
U8
1
C
Motor encoder (SSI) protocol parameters: Data package 2 start bit
0
U8
1
C
Motor encoder (SSI) protocol parameters: Data package 3 start bit
0
U8
1
C
Motor encoder (SSI) protocol parameters: Position data length
0
U8
1
C
Motor encoder (SSI) protocol parameters: Data package 1 length
0
U8
1
C
Motor encoder (SSI) protocol parameters: Data package 2 length
0
U8
1
C
Motor encoder (SSI) protocol parameters: Data package 3 length
0
U8
1
C
Motor encoder (SSI) protocol parameters: Position data coding
Binary [0]
U8
C
Motor encoder (SSI) protocol parameters: Data package 1 coding
Binary [0]
U8
C
Motor encoder (SSI) protocol parameters: Data package 2 coding
Binary [0]
U8
C
Motor encoder (SSI) protocol parameters: Data package 3 coding
Binary [0]
U8
C
Motor encoder (SSI) protocol parameters: Position raw data
- (Read only)
U32
1
-
●
Motor encoder (SSI) protocol parameters: Data package 1 raw data
- (Read only)
U32
1
-
●
Motor encoder (SSI) protocol parameters: Data package 2 raw data
- (Read only)
U32
1
-
●
Motor encoder (SSI) protocol parameters: Data package 3 raw data
- (Read only)
U32
1
-
●
Motor encoder (SSI) protocol parameters: Encoder type
Rotative encoder [0]
U8
C
Motor encoder (SSI) protocol parameters: Position raw data scaled by 0x608F
- (Read only)
I32
1
-
●
Motor encoder (SSI) protocol parameters: Monoflop time
0
U16
1
C
Motor encoder (SSI) protocol parameters: Resulting SSI-telegram cycle time
- (Read only)
U16
10
-
Motor encoder (HDSL): Release version
- (Read only)
U8
1
-
Motor encoder (HDSL): Release Date
- (Read only)
U32
1
-
Motor encoder (HDSL): Encoder ID
- (Read only)
U32
1
-
Motor encoder (HDSL): Type of encoder
- (Read only)
U16
1
-
Motor encoder (HDSL): Resolution
- (Read only)
U32
1
-
Motor encoder (HDSL): Measurement range
- (Read only)
U32
1
-
Motor encoder (HDSL): Type name
- (Read only)
STRING[50]
-
Motor encoder (HDSL): Serial number
- (Read only)
STRING[50]
-
Motor encoder (HDSL): Device version
- (Read only)
STRING[50]
-
Motor encoder (HDSL): Firmware date
- (Read only)
STRING[50]
-
Motor encoder (HDSL): EEPROM size
- (Read only)
U16
1
-
Motor encoder (HDSL): Safe Channel 2 Resolution
- (Read only)
U32
1
-
Motor encoder (HDSL): Delay / RSSI
- (Read only)
U8
H
Motor encoder (HDSL): Quality monitoring
- (Read only)
U8
H
Motor encoder (HDSL): Slave RSSI
- (Read only)
U8
H
Motor encoder (HDSL): Supply voltage
x.xxx V (Read only)
U16
1000
-
Motor encoder (HDSL): Rotation speed range
x rpm (Read only)
U16
1
-
Motor encoder (HDSL): Auswahl
No value [0]
U16
-
Motor encoder (HDSL): Value
- (Read only)
I64
1
-
Motor encoder (HDSL): Communication error counter
- (Read only)
U32
1
-
Motor encoder (HDSL): Events
- (Read only)
U16
H
Motor encoder (HDSL): Status summaries
- (Read only)
U8
H
Motor encoder (HDSL): Encoder status, byte 0
- (Read only)
U8
H
Motor encoder (HDSL): Encoder status, byte 1
- (Read only)
U8
H
Motor encoder (HDSL): Encoder status, byte 2
- (Read only)
U8
H
Motor encoder (HDSL): Encoder status, byte 3
- (Read only)
U8
H
Motor encoder (HDSL): Encoder status, byte 4
- (Read only)
U8
H
Motor encoder (HDSL): Encoder status, byte 5
- (Read only)
U8
H
Motor encoder (HDSL): Encoder status, byte 6
- (Read only)
U8
H
Motor encoder (HDSL): Encoder status, byte 7
- (Read only)
U8
H
Motor encoder (HDSL): Fast position
- (Read only)
I64
1
-
Parameter CRC of motor encoder
- (Read only)
U32
1
-
Load encoder/master encoder type
SinCos encoder [1]
U8
C
Load encoder/master encoder settings (HIPERFACE®): Type code detected
- (Read only)
U8
1
-
Load encoder/master encoder settings (HIPERFACE®): Type code manual input
0
U8
1
C
Load encoder/master encoder settings (HIPERFACE®): Manual input - Number of detectable load/master encoder revolutions
1
U16
1
C
Load encoder/master encoder settings (HIPERFACE®): Error response
Fault > CiA402 [1]
U8
-
Load encoder/master encoder settings (HIPERFACE®): Serial number
- (Read only)
STRING[50]
-
Load encoder/master encoder settings (HIPERFACE®): Actual position (raw data)
- (Read only)
U32
1
-
●
Load encoder/master encoder settings (HIPERFACE®): No. of periods detected
- (Read only)
U16
1
-
●
Load encoder/master encoder settings (HIPERFACE®): Type code verification
- (Read only)
U8
-
●
Load encoder/master encoder settings (HIPERFACE®): Encoder type
- (Read only)
U8
-
●
Load encoder/master encoder settings (HIPERFACE®): Period length linear encoder
x nm (Read only)
U32
1
-
●
Load encoder/master encoder settings (encoder): Increments/revolution
1024
U32
1
C
Load encoder/master encoder settings (encoder): Supply voltage
5.0 V
U8
10
C
Load encoder/master encoder settings (encoder): Angle drift
x.x ° (Read only)
I16
10
-
●
Load encoder/master encoder settings (encoder): Actual amplitude signal quality
x % (Read only)
U8
1
-
Load encoder/master encoder settings (encoder): Encoder voltage cos track
x.xxx V (Read only)
I16
1000
-
Load encoder/master encoder settings (encoder): Encoder voltage sin track
x.xxx V (Read only)
I16
1000
-
Load encoder/master encoder settings (encoder): TTL/HTL signal evaluation
High resolution encoder - 4-fold evaluation [1]
U8
C
Load encoder/master encoder resolver number of pole pairs
1
U8
1
C
Load encoder/master encoder identification (Resolver): Angle
0
I16
1
-
Load encoder/master encoder identification (Resolver): Cosine track gain
100 %
U16
1
-
Load encoder/master encoder identification (Resolver): Sine track gain
100 %
U16
1
-
Load encoder/master encoder identification (Resolver): Identification status
- (Read only)
U16
H
Load encoder/master encoder identification (Resolver): Cosine track offset
0.000 %
I32
1000
-
Load encoder/master encoder identification (Resolver): Sine track offset
0.000 %
I32
1000
-
Load encoder/master encoder identification (Resolver): Dead time compensation resolver evaluation
100.0 %
I16
10
-
Load encoder/master encoder error response
Fault > CiA402 [1]
U8
-
Number of the absolute ascertainable revolutions of load encoder/master encoder
- (Read only)
U16
1
-
Open circuit detection sensitivity of load encoder/master encoder
100 %
U8
1
-
Load encoder (EnDat): Response communication error
Fault > CiA402 [1]
U8
-
Load encoder (EnDat): Actual position (raw data)
- (Read only)
U32
1
-
●
Load encoder (EnDat): Serial number
- (Read only)
STRING[50]
-
Load encoder (EnDat): ID number
- (Read only)
STRING[50]
-
Load encoder (EnDat): Encoder designation
- (Read only)
STRING[50]
-
Load encoder (EnDat): EnDat ordering designation
- (Read only)
STRING[50]
-
Load encoder (EnDat): EnDat command set
- (Read only)
STRING[50]
-
Load encoder (EnDat): Encoder type
- (Read only)
U8
1
-
Load encoder (EnDat): Signal periods per revolution/Length of signal period
- (Read only)
U32
1
-
Load encoder (EnDat): Distinguishable revolutions
- (Read only)
U16
1
-
Load encoder (EnDat): Max. clock frequency
x kHz (Read only)
U16
1
-
Load encoder (EnDat): Measuring step or measuring steps/rev for serial data transmission
- (Read only)
U32
1
-
Load encoder (EnDat): Scaling factor for resolution
- (Read only)
U16
1
-
Load encoder (EnDat): Measuring step, or measuring steps/rev or subdivision values of a grating period
- (Read only)
U32
1
-
Load encoder/master encoder (SSI) protocol parameters: Bit rate
300 kbps
U16
1
C
Load encoder/master encoder (SSI) protocol parameters: Telegram length
25
U8
1
C
Load encoder/master encoder (SSI) protocol parameters: Bits/revolution
13
U8
1
C
Load encoder/master encoder (SSI) protocol parameters: Position data start bit
0
U8
1
C
Load encoder/master encoder (SSI) protocol parameters: Data package 1 start bit
0
U8
1
C
Load encoder/master encoder (SSI) protocol parameters: Data package 2 start bit
0
U8
1
C
Load encoder/master encoder (SSI) protocol parameters: Data package 3 start bit
0
U8
1
C
Load encoder/master encoder (SSI) protocol parameters: Position data length
25
U8
1
C
Load encoder/master encoder (SSI) protocol parameters: Data package 1 length
0
U8
1
C
Load encoder/master encoder (SSI) protocol parameters: Data package 2 length
0
U8
1
C
Load encoder/master encoder (SSI) protocol parameters: Data package 3 length
0
U8
1
C
Load encoder/master encoder (SSI) protocol parameters: Position data coding
Binary [0]
U8
C
Load encoder/master encoder (SSI) protocol parameters: Data package 1 coding
Binary [0]
U8
C
Load encoder/master encoder (SSI) protocol parameters: Data package 2 coding
Binary [0]
U8
C
Load encoder/master encoder (SSI) protocol parameters: Data package 3 coding
Binary [0]
U8
C
Load encoder/master encoder (SSI) protocol parameters: Position raw data
- (Read only)
U32
1
-
●
Load encoder/master encoder (SSI) protocol parameters: Data package 1 raw data
- (Read only)
U32
1
-
●
Load encoder/master encoder (SSI) protocol parameters: Data package 2 raw data
- (Read only)
U32
1
-
●
Load encoder/master encoder (SSI) protocol parameters: Data package 3 raw data
- (Read only)
U32
1
-
●
Load encoder/master encoder (SSI) protocol parameters: Encoder type
Rotative encoder [0]
U8
C
Load encoder/master encoder (SSI) protocol parameters: Position raw data scaled by 0x608F
- (Read only)
I32
1
-
●
Load encoder/master encoder (SSI) protocol parameters: Monoflop time
0
U16
1
C
Load encoder/master encoder (SSI) protocol parameters: Resulting SSI-telegram cycle time
- (Read only)
U16
10
-
Parameter CRC of load encoder/master encoder
- (Read only)
U32
1
-
PPI monitoring: Response
Fault > CiA402 [1]
U8
-
Pole position identification (360°) settings: Current amplitude
71 %
U16
1
C
Pole position identification (360°) settings: Ramp time
40 s
U16
1
C
Pole position identification (360°) settings: Direction of rotation
CW [0]
U8
C
Pole position identification (360°) settings: Error tolerance
20 °
U8
1
-
Pole position identification (360°) settings: Absolute current amplitude
x.xx A (Read only)
U32
100
-
Pole position identification (360°) settings: ixt threshold for reversal of rotating direction
30 %
U8
1
-
Pole position identification (360°) settings: Actual commutation angle
x.xxx ° (Read only)
U32
1000
-
Pole position identification (min. movement) settings: Current amplitude
25 %
U16
1
C
Pole position identification (min. movement) settings: Ramp time
10 s
U16
1
C
Pole position identification (min. movement) settings: Gain
0 %
U16
1
-
Pole position identification (min. movement) settings: Reset time
62.5 ms
U16
10
-
Pole position identification (min. movement) settings: Max. move permitted
20 °
U8
1
-
Pole position identification (min. movement) settings: Absolute current amplitude
x.xx A (Read only)
U32
100
-
PPI without movement: Execution
Disabled [0]
U8
C
PPI without movement: Current adjust factor
100 %
U16
1
C
Cable Check: Behavior after switch on
No action [0]
U8
C
Cable Check: Status word
- (Read only)
U16
H
PPI validation: Activation
Off [0]
U8
C
PPI validation: Settings
No action [0]
U8
-
PPI validation: Status
- (Read only)
U16
H
●
PPI validation: Pole position set value
0.0 °
I16
10
-
PPI mode for 0x6060: Selection
PPI 360° [1]
U8
C
MOL settings for 0x6060: Current setpoint 1
71 %
U16
1
-
MOL settings for 0x6060: Frequency 1
1.0 Hz
I16
10
-
MOL settings for 0x6060: Current 1 - ramp time
10 ms
U16
1
-
MOL settings for 0x6060: Frequency 1 - ramp time
200 ms
U16
1
-
MOL settings for 0x6060: Starting angle 1
0.0 °
I16
10
-
MOL settings for 0x6060: Stopping time 1
10000.0 s
U32
10
C
MOL settings for 0x6060: Current setpoint 2
71 %
U16
1
-
MOL settings for 0x6060: Frequency 2
5.0 Hz
I16
10
-
MOL settings for 0x6060: Current 2 - ramp time
10 ms
U16
1
-
MOL settings for 0x6060: Frequency 2 - ramp time
1000 ms
U16
1
-
MOL settings for 0x6060: Starting angle 2
0.0 °
I16
10
-
MOL settings for 0x6060: Stopping time 2
10000.0 s
U32
10
C
Touch probe (TP) delay time: Touch probe 1 delay time
0.000 ms
U16
1000
-
Touch probe (TP) delay time: Touch probe 2 delay time
0.000 ms
U16
1000
-
Touch probe (TP) delay time: Touch probe 3 delay time
0.000 ms
U16
1000
-
Touch probe (TP) delay time: Touch probe 4 delay time
0.000 ms
U16
1000
-
Touch probe (TP) time stamp: Touch probe 1-rising edge time stamp
x ns (Read only)
U32
1
-
●
Touch probe (TP) time stamp: Touch probe 1-falling edge time stamp
x ns (Read only)
U32
1
-
●
Touch probe (TP) time stamp: Touch probe 2-rising edge time stamp
x ns (Read only)
U32
1
-
●
Touch probe (TP) time stamp: Touch probe 2-falling edge time stamp
x ns (Read only)
U32
1
-
●
Touch probe (TP) time stamp: Touch probe 3-rising edge time stamp
x ns (Read only)
U32
1
-
●
Touch probe (TP) time stamp: Touch probe 3-falling edge time stamp
x ns (Read only)
U32
1
-
●
Touch probe (TP) time stamp: Touch probe 4-rising edge time stamp
x ns (Read only)
U32
1
-
●
Touch probe (TP) time stamp: Touch probe 4-falling edge time stamp
x ns (Read only)
U32
1
-
●
Touch probe diagnostics: Touch probe 3/4 function
0x0000
U16
H
●
Touch probe diagnostics: Touch-Probe 3/4 status
- (Read only)
U16
H
●
Touch probe position: Touch probe 3 position rising edge
- (Read only)
I32
1
-
●
Touch probe position: Touch probe 3 position falling edge
- (Read only)
I32
1
-
●
Touch probe position: Touch probe 4 position rising edge
- (Read only)
I32
1
-
●
Touch probe position: Touch probe 4 position falling edge
- (Read only)
I32
1
-
●
Device utilisation ixt: Power unit actual utilisation
x % (Read only)
U16
1
-
●
Device utilisation ixt: Power unit warning threshold
95 %
U16
1
-
Device utilisation ixt: Power unit error threshold
x % (Read only)
U16
1
-
Device utilisation ixt: Device actual utilisation
x % (Read only)
U16
1
-
●
Device utilisation ixt: Device warning threshold
95 %
U16
1
-
Device utilisation ixt: Device error threshold
x % (Read only)
U16
1
-
Device utilisation ixt: Actual total utilisation
x % (Read only)
U16
1
-
●
Device utilisation ixt: Total utilisation warning threshold
95 %
U16
1
-
Device utilisation ixt: Total utilisation error threshold
x % (Read only)
U16
1
-
Overspeed monitoring: Threshold
8000 rpm
U16
1
-
Overspeed monitoring: Response
Fault > CiA402 [1]
U8
-
Motor phase failure detection: Response - Motor phase 1
No response [0]
U8
-
Motor phase failure detection: Current threshold
5.0 %
U8
10
-
Motor phase failure detection: Voltage threshold
10.0 V
U16
10
-
Motor phase failure detection: Response - Motor phase 2
No response [0]
U8
-
Overcurrent monitoring: Threshold
5.4 A
U16
10
-
Overcurrent monitoring: Response
Fault > CiA402 [1]
U8
-
PTC temperature sensor monitoring: Error response
Fault > CiA402 [1]
U8
-
Motor temperature monitoring: Temperature sensor type
PT1000 [5]
U8
-
Motor temperature monitoring: Response
Warning [1]
U8
-
Motor temperature monitoring: Warning threshold
145.0 °C
I16
10
-
Motor temperature monitoring: Error threshold
155.0 °C
I16
10
-
Motor temperature monitoring: Actual motor temperature
x.x °C (Read only)
I16
10
-
●
Motor temperature monitoring: Spec. characteristic temperature grid point 1
25.0 °C
I16
10
-
Motor temperature monitoring: Spec. characteristic temperature grid point 2
150.0 °C
I16
10
-
Motor temperature monitoring: Spec. characteristic resistance grid point 1
1000 Ω
I16
1
-
Motor temperature monitoring: Spec. characteristic resistance grid point 2
2225 Ω
I16
1
-
Motor temperature monitoring: Temperature sensor feedback type
Motor encoder [0]
U8
-
Motor temperature monitoring: Motor temperature (Motor encoder)
x.x °C (Read only)
I16
10
-
●
Motor temperature monitoring: Motor temperature (load encoder)
x.x °C (Read only)
I16
10
-
●
Thermal model motor utilization (i²xt): Motor utilisation (i²xt)
60 s
U16
1
-
Thermal model motor utilization (i²xt): Thermal time constant - laminations
852 s
U16
1
-
Thermal model motor utilization (i²xt): Winding influence
27 %
U8
1
-
Thermal model motor utilization (i²xt): Starting value
0 %
U16
1
-
Motor utilisation (i²xt) - specific characteristic: x1 = n01/nN (n01 ~ 0)
0 %
U16
1
-
Motor utilisation (i²xt) - specific characteristic: y1 = i01/iN (x1)
100 %
U16
1
-
Motor utilisation (i²xt) - specific characteristic: x2 = n02/nN (n02 = limit reduced cooling)
0 %
U16
1
-
Motor utilisation (i²xt) - specific characteristic: y2 = i02/iN (x2)
100 %
U16
1
-
Motor utilisation (i²xt) - specific characteristic: x3 = n03/nN (n03 = rated speed)
100 %
U16
1
-
Motor utilisation (i²xt) - specific characteristic: y3 = i03/iN (x3)
100 %
U16
1
-
Motor utilisation (i²xt) - specific characteristic: x4 = n04/nN (n04 = limit field weakening)
100 %
U16
1
-
Motor utilisation (i²xt) - specific characteristic: y4 = i04/iN (x4)
100 %
U16
1
-
Motor utilisation (i²xt) - warning threshold
100 %
U16
1
-
Motor utilisation (i²xt)
x % (Read only)
U16
1
-
●
Motor utilisation (i²xt) - monitoring: Error response
Fehler > CiA402 [1]
U8
-
Motor utilisation (i²xt) - monitoring: Error threshold
105 %
U16
1
-
Position error/speed error - monitoring: Speed error - error threshold
50 rpm
U32
1
-
Position error/speed error - monitoring: Speed error - min. time for error
0 ms
U16
1
-
Position error/speed error - monitoring: Speed error - error response
No response [0]
U8
-
Position error/speed error - monitoring: Position error - error threshold
360 °
U32
1
-
Position error/speed error - monitoring: Position error - min. time for error
0 ms
U16
1
-
Position error/speed error - monitoring: Position error - error response
No response [0]
U8
-
Mains failure control: Enable function
Disabled [0]
U8
-
Mains failure control: DC-bus activation level
75 %
U8
1
-
Mains failure control: Filter time
0.00 s
U16
100
-
Mains failure control: Ramp max. torque
30.0 %
U16
10
-
Mains failure control: Ramp time
1.00 s
U16
100
-
Mains failure control: Actual DC bus voltage (filtered)
x.xxx V (Read only)
U32
1000
-
Life-diagnosis: Operating time
x s (Read only)
U32
1
-
Life-diagnosis: Power-on time
x s (Read only)
U32
1
-
Life-diagnosis: Main switching cycles
- (Read only)
U32
1
-
Life-diagnosis: Short-circuit counter
- (Read only)
U32
1
-
Life-diagnosis: Earth fault counter
- (Read only)
U32
1
-
Life-diagnosis: Fan operating time
x s (Read only)
U32
1
-
Motor actual voltage (Veff)
x.x V (Read only)
U32
10
-
●
Motor-Phasenströme: Zero system current
x.xx A (Read only)
I32
100
-
●
Motor-Phasenströme: Phase U current
x.xx A (Read only)
I32
100
-
●
Motor-Phasenströme: Phase V current
x.xx A (Read only)
I32
100
-
●
Motor-Phasenströme: Phase W current
x.xx A (Read only)
I32
100
-
●
Heatsink temperature: Heatsink temperature
x.x °C (Read only)
I16
10
-
Heatsink temperature: Warning threshold
90.0 °C
I16
10
-
Actual speed error
x rpm (Read only)
I32
1
-
●
Output power: Effective power
x.xxx kW (Read only)
I32
1000
-
●
Output energy: Overall energy
0.00 kWh
I32
100
-
Diagnostics of analog input 1: Value in percent
x.x % (Read only)
I16
10
-
Diagnostics of analog input 1: Scaled percent value
x.xx % (Read only)
I16
100
-
●
Diagnostics of analog input 1: Status
- (Read only)
U16
H
●
Diagnostics of analog input 2: Value in percent
x.x % (Read only)
I16
10
-
Diagnostics of analog input 2: Scaled percent value
x.xx % (Read only)
I16
100
-
●
Diagnostics of analog input 2: Status
- (Read only)
U16
H
●
Diagnostics of analog output 1: Voltage
x.xx V (Read only)
U16
100
-
Field values: Actual value
x % (Read only)
U16
1
-
●
Field values: Setpoint value
x % (Read only)
U16
1
-
●
Motor currents: Actual D-current (id)
x.xx A (Read only)
I32
100
-
●
Motor currents: Actual Q-current (iq)
x.xx A (Read only)
I32
100
-
●
Motor currents: Setpoint D-current (id)
x.xx A (Read only)
I32
100
-
●
Motor currents: Setpoint Q-current (iq)
x.xx A (Read only)
I32
100
-
●
Motor currents: Motor current (Ieff)
x.xx A (Read only)
I32
100
-
●
Target position interpolated
- (Read only)
I32
1
-
●
Speed setpoints: Speed setpoint
x rpm (Read only)
I32
1
-
●
Speed setpoints: Speed setpoint 2
x rpm (Read only)
I32
1
-
●
Speed setpoints: Speed setpoint limited
x rpm (Read only)
I32
1
-
●
Speed controller output signals: Output signal 1
x.x % (Read only)
I16
10
-
●
Speed controller output signals: Output signal 2
x.x % (Read only)
I16
10
-
●
Torque setpoint
x.xx Nm (Read only)
I32
100
-
●
Torque filter cascade: Starting value
x.x % (Read only)
I16
10
-
●
Torque filter cascade: Notch filter 1 input value
x.x % (Read only)
I16
10
-
●
Torque filter cascade: Notch filter 2 input value
x.x % (Read only)
I16
10
-
●
Torque filter cascade: Torque setpoint filtered
x.x % (Read only)
I16
10
-
●
Voltage values: Actual voltage (motor voltage limit)
x.x V (Read only)
I16
10
-
●
Voltage values: Output signal D current controller
x.x V (Read only)
I16
10
-
●
Voltage values: Output signal Q current controller
x.x V (Read only)
I16
10
-
●
Voltage values: D voltage (magnetisation)
x.x V (Read only)
I16
10
-
●
Voltage values: Q voltage (torque)
x.x V (Read only)
I16
10
-
●
Voltage values: Phases U-V
x.x V (Read only)
I16
10
-
●
Voltage values: Phases V-W
x.x V (Read only)
I16
10
-
●
Voltage values: Phases W-U
x.x V (Read only)
I16
10
-
●
Voltage values: Phase U
x.x V (Read only)
I16
10
-
●
Voltage values: Phase V
x.x V (Read only)
I16
10
-
●
Voltage values: Phase W
x.x V (Read only)
I16
10
-
●
Actual slip value
x.x Hz (Read only)
I16
10
-
●
Output frequency
x.x Hz (Read only)
I16
10
-
●
Actual rotor angle position
- (Read only)
I16
1
-
●
Axis information: Rated current
x.xx A (Read only)
U16
100
-
●
Axis information: Maximum current
x.xx A (Read only)
U16
100
-
●
Axis information: Detected module in slot A
- (Read only)
U8
-
●
Axis information: Detected module in slot B
- (Read only)
U8
-
●
Axis information: Function of X109
- (Read only)
U8
-
●
Current controller identification settings
Automatic [0]
U8
-
Resolver - position detection dynamics
100 %
U16
1
-
Resolver - 8 kHz safety signal
Automatisch durch Gerätetyp [0]
U8
-
OEM service Data - SN
- (Read only)
U32
1
-
Use measured voltage
On [1]
U8
-
Motor identification settings
- (Read only)
U32
1
-
Overwrite bit 4 of CiA control word
No overwrite [0]
U8
-
0x2DE0:026
Actual speed filter time
10.0 ms
U16
10
-
Axis settings: Function of X109
PTC [20]
U8
-
Application selection
CiA 402 [0]
U16
C
Digital output 1: Terminal state
- (Read only)
U8
-
Application diagnostics: Application state
- (Read only)
U8
-
EtherCAT master commands: Kommunikation neu starten
No action/no error [0]
U16
-
EtherCAT master diagnosis: EtherCAT master state
- (Read only)
U16
-
EtherCAT master diagnosis: EtherCAT master state summary
- (Read only)
U32
H
EtherCAT master diagnosis: EtherCAT error
- (Read only)
U16
1
-
EtherCAT master diagnosis: Bus scan match
- (Read only)
U8
1
-
EtherCAT master diagnosis: Configured cycle time
- (Read only)
U32
1
-
EtherCAT master diagnosis: Connected slaves
- (Read only)
U16
1
-
EtherCAT master diagnosis: Configured slaves
- (Read only)
U16
1
-
EtherCAT slaves station addresses: Station address slave 1
- (Read only)
I16
1
-
EtherCAT slaves station addresses: Station address slave 2
- (Read only)
I16
1
-
EtherCAT slaves station addresses: Station address slave 3
- (Read only)
I16
1
-
EtherCAT slaves station addresses: Station address slave 4
- (Read only)
I16
1
-
EtherCAT slaves station addresses: Station address slave 5
- (Read only)
I16
1
-
EtherCAT slaves station addresses: Station address slave 6
- (Read only)
I16
1
-
EtherCAT slaves station addresses: Station address slave 7
- (Read only)
I16
1
-
EtherCAT slaves station addresses: Station address slave 8
- (Read only)
I16
1
-
EtherCAT slaves station addresses: Station address slave 9
- (Read only)
I16
1
-
EtherCAT slaves station addresses: Station address slave 10
- (Read only)
I16
1
-
EtherCAT slaves station addresses: Station address slave 11
- (Read only)
I16
1
-
EtherCAT slaves station addresses: Station address slave 12
- (Read only)
I16
1
-
EtherCAT slaves station addresses: Station address slave 13
- (Read only)
I16
1
-
EtherCAT slaves station addresses: Station address slave 14
- (Read only)
I16
1
-
EtherCAT slaves station addresses: Station address slave 15
- (Read only)
I16
1
-
EtherCAT slaves station addresses: Station address slave 16
- (Read only)
I16
1
-
EtherCAT slaves device names: Device name slave 1
- (Read only)
STRING[128]
-
EtherCAT slaves device names: Device name slave 2
- (Read only)
STRING[128]
-
EtherCAT slaves device names: Device name slave 3
- (Read only)
STRING[128]
-
EtherCAT slaves device names: Device name slave 4
- (Read only)
STRING[128]
-
EtherCAT slaves device names: Device name slave 5
- (Read only)
STRING[128]
-
EtherCAT slaves device names: Device name slave 6
- (Read only)
STRING[128]
-
EtherCAT slaves device names: Device name slave 7
- (Read only)
STRING[128]
-
EtherCAT slaves device names: Device name slave 8
- (Read only)
STRING[128]
-
EtherCAT slaves device names: Device name slave 9
- (Read only)
STRING[128]
-
EtherCAT slaves device names: Device name slave 10
- (Read only)
STRING[128]
-
EtherCAT slaves device names: Device name slave 11
- (Read only)
STRING[128]
-
EtherCAT slaves device names: Device name slave 12
- (Read only)
STRING[128]
-
EtherCAT slaves device names: Device name slave 13
- (Read only)
STRING[128]
-
EtherCAT slaves device names: Device name slave 14
- (Read only)
STRING[128]
-
EtherCAT slaves device names: Device name slave 15
- (Read only)
STRING[128]
-
EtherCAT slaves device names: Device name slave 16
- (Read only)
STRING[128]
-
EtherCAT slaves device types: Device type slave 1
- (Read only)
STRING[50]
-
EtherCAT slaves device types: Device type slave 2
- (Read only)
STRING[50]
-
EtherCAT slaves device types: Device type slave 3
- (Read only)
STRING[50]
-
EtherCAT slaves device types: Device type slave 4
- (Read only)
STRING[50]
-
EtherCAT slaves device types: Device type slave 5
- (Read only)
STRING[50]
-
EtherCAT slaves device types: Device type slave 6
- (Read only)
STRING[50]
-
EtherCAT slaves device types: Device type slave 7
- (Read only)
STRING[50]
-
EtherCAT slaves device types: Device type slave 8
- (Read only)
STRING[50]
-
EtherCAT slaves device types: Device type slave 9
- (Read only)
STRING[50]
-
EtherCAT slaves device types: Device type slave 10
- (Read only)
STRING[50]
-
EtherCAT slaves device types: Device type slave 11
- (Read only)
STRING[50]
-
EtherCAT slaves device types: Device type slave 12
- (Read only)
STRING[50]
-
EtherCAT slaves device types: Device type slave 13
- (Read only)
STRING[50]
-
EtherCAT slaves device types: Device type slave 14
- (Read only)
STRING[50]
-
EtherCAT slaves device types: Device type slave 15
- (Read only)
STRING[50]
-
EtherCAT slaves device types: Device type slave 16
- (Read only)
STRING[50]
-
Mandatory EtherCAT slaves: Slave 1 is mandatory
- (Read only)
U8
-
Mandatory EtherCAT slaves: Slave 2 is mandatory
- (Read only)
U8
-
Mandatory EtherCAT slaves: Slave 3 is mandatory
- (Read only)
U8
-
Mandatory EtherCAT slaves: Slave 4 is mandatory
- (Read only)
U8
-
Mandatory EtherCAT slaves: Slave 5 is mandatory
- (Read only)
U8
-
Mandatory EtherCAT slaves: Slave 6 is mandatory
- (Read only)
U8
-
Mandatory EtherCAT slaves: Slave 7 is mandatory
- (Read only)
U8
-
Mandatory EtherCAT slaves: Slave 8 is mandatory
- (Read only)
U8
-
Mandatory EtherCAT slaves: Slave 9 is mandatory
- (Read only)
U8
-
Mandatory EtherCAT slaves: Slave 10 is mandatory
- (Read only)
U8
-
Mandatory EtherCAT slaves: Slave 11 is mandatory
- (Read only)
U8
-
Mandatory EtherCAT slaves: Slave 12 is mandatory
- (Read only)
U8
-
Mandatory EtherCAT slaves: Slave 13 is mandatory
- (Read only)
U8
-
Mandatory EtherCAT slaves: Slave 14 is mandatory
- (Read only)
U8
-
Mandatory EtherCAT slaves: Slave 15 is mandatory
- (Read only)
U8
-
Mandatory EtherCAT slaves: Slave 16 is mandatory
- (Read only)
U8
-
EtherCAT slaves initialisation status: Initalisation status slave 1
- (Read only)
U16
-
EtherCAT slaves initialisation status: Initalisation status slave 2
- (Read only)
U16
-
EtherCAT slaves initialisation status: Initalisation status slave 3
- (Read only)
U16
-
EtherCAT slaves initialisation status: Initalisation status slave 4
- (Read only)
U16
-
EtherCAT slaves initialisation status: Initalisation status slave 5
- (Read only)
U16
-
EtherCAT slaves initialisation status: Initalisation status slave 6
- (Read only)
U16
-
EtherCAT slaves initialisation status: Initalisation status slave 7
- (Read only)
U16
-
EtherCAT slaves initialisation status: Initalisation status slave 8
- (Read only)
U16
-
EtherCAT slaves initialisation status: Initalisation status slave 9
- (Read only)
U16
-
EtherCAT slaves initialisation status: Initalisation status slave 10
- (Read only)
U16
-
EtherCAT slaves initialisation status: Initalisation status slave 11
- (Read only)
U16
-
EtherCAT slaves initialisation status: Initalisation status slave 12
- (Read only)
U16
-
EtherCAT slaves initialisation status: Initalisation status slave 13
- (Read only)
U16
-
EtherCAT slaves initialisation status: Initalisation status slave 14
- (Read only)
U16
-
EtherCAT slaves initialisation status: Initalisation status slave 15
- (Read only)
U16
-
EtherCAT slaves initialisation status: Initalisation status slave 16
- (Read only)
U16
-
EtherCAT slaves device status: Device status slave 1
- (Read only)
U16
-
EtherCAT slaves device status: Device status slave 2
- (Read only)
U16
-
EtherCAT slaves device status: Device status slave 3
- (Read only)
U16
-
EtherCAT slaves device status: Device status slave 4
- (Read only)
U16
-
EtherCAT slaves device status: Device status slave 5
- (Read only)
U16
-
EtherCAT slaves device status: Device status slave 6
- (Read only)
U16
-
EtherCAT slaves device status: Device status slave 7
- (Read only)
U16
-
EtherCAT slaves device status: Device status slave 8
- (Read only)
U16
-
EtherCAT slaves device status: Device status slave 9
- (Read only)
U16
-
EtherCAT slaves device status: Device status slave 10
- (Read only)
U16
-
EtherCAT slaves device status: Device status slave 11
- (Read only)
U16
-
EtherCAT slaves device status: Device status slave 12
- (Read only)
U16
-
EtherCAT slaves device status: Device status slave 13
- (Read only)
U16
-
EtherCAT slaves device status: Device status slave 14
- (Read only)
U16
-
EtherCAT slaves device status: Device status slave 15
- (Read only)
U16
-
EtherCAT slaves device status: Device status slave 16
- (Read only)
U16
-
Error code
- (Read only)
U16
H
●
CiA control word
0x0000
U16
H
●
CiA status word
- (Read only)
U16
H
●
Set speed
0 rpm
I16
1
-
●
Internal set speed
x rpm (Read only)
I16
1
-
●
Actual speed
x rpm (Read only)
I16
1
-
●
Speed limits: Min. speed
0 rpm
U32
1
-
●
Speed limits: Max. speed
2147483647 rpm
U32
1
-
●
Acceleration ramp: CiA acceleration: Delta speed
0 rpm
U32
1
-
●
Acceleration ramp: CiA acceleration: Delta time
10 s
U16
1
-
●
Deceleration ramp: CiA deceleration: Delta speed
0 rpm
U32
1
-
●
Deceleration ramp: CiA deceleration: Delta time
10 s
U16
1
-
●
vl set-point factor: vl set-point factor numerator
1
I16
1
-
●
vl set-point factor: vl set-point factor denominator
1
I16
1
-
●
vl dimension factor: vl dimension factor numerator
1
I32
1
-
●
vl dimension factor: vl dimension factor denominator
1
I32
1
-
●
CiA: Quick stop mode
Ramp > switch on disabled [2]
I16
-
Shutdown option code
Disable drive function [0]
I16
-
CiA: Response to minor faults
Advanced quick stop [-2]
I16
-
CiA: Operation mode
No selection [0]
I8
-
●
CiA: Active operation mode
- (Read only)
I8
-
●
Internal set position
- (Read only)
I32
1
-
Internal actual position
- (Read only)
I32
1
-
●
Actual position
- (Read only)
I32
1
-
●
Following error window
1000
U32
1
-
●
Following error delay
0 ms
U16
1
-
●
Position reached window
1000
U32
1
-
Position reached delay
0 ms
U16
1
-
Actual speed
rpm (Read only)
I32
480000/2147483647
-
●
Set torque
0.0 %
I16
10
-
●
Max. torque
250.0 %
U16
10
-
●
Max. current
150.0 %
U16
10
-
Internal set torque
x.x % (Read only)
I16
10
-
Rated motor current
1.300 A
U32
1000
C
Rated motor torque
0.600 Nm
U32
1000
C
Actual torque
x.x % (Read only)
I16
10
-
●
Actual current
x.x % (Read only)
I16
10
-
●
DC-bus voltage
x.xxx V (Read only)
U32
1000
-
●
Set position
0
I32
1
-
●
Polarity
0
U8
1
C
Max. motor speed
6075 rpm
U32
1
-
●
Quick stop deceleration
2147483647
U32
1
-
Position encoder resolution: Encoder increments
16 bit [65536]
U32
C
Position encoder resolution: Motor revolutions
1
U32
1
C
Velocity encoder resolution: Encoder increments/s
33554432
U32
1
C
Velocity encoder resolution: Motor revolutions/s
125
U32
1
C
Offset speed
0.00 rpm
I32
480000/2147483647
-
●
Offset torque
0.0 %
I16
10
-
●
Touch probe settings
0x0000
U16
H
●
Touch probe status
- (Read only)
U16
H
●
Touch probe 1: Position at pos. edge
- (Read only)
I32
1
-
●
Touch probe 1: Position at neg. edge
- (Read only)
I32
1
-
●
Touch probe 2: Position at pos. edge
- (Read only)
I32
1
-
●
Touch probe 2: Position at neg. edge
- (Read only)
I32
1
-
●
Interpolation mode
Quadratic [-1]
I16
-
●
Interpolation time: Interpolation time mantissa
1
U8
1
-
Interpolation time: Interpolation time exponent
-3
I8
1
-
Positive torque limit
100.0 %
U16
10
-
●
Negative torque limit
100.0 %
U16
10
-
●
Additional position actual value: Load encoder/master encoder - actual position
- (Read only)
I32
1
-
●
Additional velocity actual value: Load encoder/master encoder - actual speed
rpm (Read only)
I32
480000/2147483647
-
●
Additional position encoder resolution - encoder increments: Load encoder/master encoder - number of increments
16 Bit [65536]
U32
C
Additional position encoder resolution - motor revolutions: Load encoder/master encoder - resolution of motor revolutions
1
U32
1
C
Following error actual value
- (Read only)
I32
1
-
●
Control effort
rpm (Read only)
I32
480000/2147483647
-
●
Position demand internal value
- (Read only)
I32
1
-
Digital input status
- (Read only)
U32
H
●
Digital outputs: Digtal output status
0x00000000
U32
H
●
Set speed
0.00 rpm
I32
480000/2147483647
-
●
Motor manufacturer
"Lenze"
STRING[50]
-
Supported drive modes
- (Read only)
U32
H
Device profile number
- (Read only)
U32
1
-
Systembus output data: Systembus data output 1
- (Read only)
U32
1
-
●
Systembus output data: Systembus data output 2
- (Read only)
U32
1
-
●
Systembus output data: Systembus data output 3
- (Read only)
U32
1
-
●
Systembus output data: Systembus data output 4
- (Read only)
U32
1
-
●
Systembus output data: Systembus data output 5
- (Read only)
U32
1
-
●
Systembus output data: Systembus data output 6
- (Read only)
U32
1
-
●
Systembus output data: Systembus data output 7
- (Read only)
U32
1
-
●
Systembus output data: Systembus data output 8
- (Read only)
U32
1
-
●
Systembus output data: Systembus data output 9
- (Read only)
U32
1
-
●
Systembus output data: Systembus data output 10
- (Read only)
U32
1
-
●
Systembus output data: Systembus data output 11
- (Read only)
U32
1
-
●
Systembus output data: Systembus data output 12
- (Read only)
U32
1
-
●
Systembus output data: Systembus data output 13
- (Read only)
U32
1
-
●
Systembus output data: Systembus data output 14
- (Read only)
U32
1
-
●
Systembus output data: Systembus data output 15
- (Read only)
U32
1
-
●
Systembus output data: Systembus data output 16
- (Read only)
U32
1
-
●
Systembus input data: Systembus data input 1
0
U32
1
-
●
Systembus input data: Systembus data input 2
0
U32
1
-
●
Systembus input data: Systembus data input 3
0
U32
1
-
●
Systembus input data: Systembus data input 4
0
U32
1
-
●
Systembus input data: Systembus data input 5
0
U32
1
-
●
Systembus input data: Systembus data input 6
0
U32
1
-
●
Systembus input data: Systembus data input 7
0
U32
1
-
●
Systembus input data: Systembus data input 8
0
U32
1
-
●
Systembus input data: Systembus data input 9
0
U32
1
-
●
Systembus input data: Systembus data input 10
0
U32
1
-
●
Systembus input data: Systembus data input 11
0
U32
1
-
●
Systembus input data: Systembus data input 12
0
U32
1
-
●
Systembus input data: Systembus data input 13
0
U32
1
-
●
Systembus input data: Systembus data input 14
0
U32
1
-
●
Systembus input data: Systembus data input 15
0
U32
1
-
●
Systembus input data: Systembus data input 16
0
U32
1
-
●
FSoE Slave Frame Elements: Command
- (Read only)
U8
1
-
●
FSoE Slave Frame Elements: Connection ID
- (Read only)
U16
1
-
●
FSoE Slave Frame Elements: CRC_0
- (Read only)
U16
1
-
●
FSoE Slave Frame Elements: CRC_1
- (Read only)
U16
1
-
●
FSoE Slave Frame Elements: CRC_2
- (Read only)
U16
1
-
●
FSoE Slave Frame Elements: CRC_3
- (Read only)
U16
1
-
●
FSoE Slave Frame Elements: CRC_4
- (Read only)
U16
1
-
●
FSoE Slave Frame Elements: CRC_5
- (Read only)
U16
1
-
●
FSoE Slave Frame Elements: CRC_6
- (Read only)
U16
1
-
●
FSoE Master Frame Elements: Command
- (Read only)
U8
1
-
●
FSoE Master Frame Elements: Connection ID
- (Read only)
U16
1
-
●
FSoE Master Frame Elements: CRC_0
- (Read only)
U16
1
-
●
FSoE Master Frame Elements: CRC_1
- (Read only)
U16
1
-
●
FSoE Connection Communication Parameter: Version
- (Read only)
STRING[2]
-
FSoE Connection Communication Parameter: Safety address
- (Read only)
U16
1
-
FSoE Connection Communication Parameter: Connection ID
- (Read only)
U16
1
-
FSoE Connection Communication Parameter: Watchdog Time
- (Read only)
U16
1
-
FSoE Connection Communication Parameter: Connection Type
- (Read only)
U16
-
FSoE Connection Communication Parameter: Communication Parameter Length
- (Read only)
U16
1
-
FSoE Connection Communication Parameter: Application Parameter Length
- (Read only)
U16
1
-
FSoE Connection Diagnosis: Connection State
- (Read only)
U16
-
Safety addresses: FSoE address
- (Read only)
U16
1
-
Safety addresses: Safety address
1
U16
1
-